一、WBDG-2000電容電感試(shi)驗儀(yi)產品概述
無(wu)功(gong)(gong)(gong)補(bu)償電(dian)(dian)(dian)(dian)(dian)容(rong)器(qi)(qi)是(shi)滿足電(dian)(dian)(dian)(dian)(dian)力系(xi)統無(wu)功(gong)(gong)(gong)平衡的(de)(de)重要設(she)備(bei)。近年來無(wu)功(gong)(gong)(gong)問題得到了電(dian)(dian)(dian)(dian)(dian)業(ye)部門的(de)(de)普遍重視(shi),無(wu)功(gong)(gong)(gong)補(bu)償成套裝(zhuang)置(zhi)已大(da)(da)(da)量投入配電(dian)(dian)(dian)(dian)(dian)網運(yun)行(xing)(xing)。電(dian)(dian)(dian)(dian)(dian)能(neng)供給要求系(xi)統有(you)(you)功(gong)(gong)(gong)與無(wu)功(gong)(gong)(gong)實時平衡。因此,無(wu)功(gong)(gong)(gong)補(bu)償裝(zhuang)置(zhi)應滿足自動跟蹤(zong)、實時補(bu)償的(de)(de)要求,這就(jiu)不可避(bi)(bi)免地要頻繁(fan)投、切無(wu)功(gong)(gong)(gong)補(bu)償電(dian)(dian)(dian)(dian)(dian)容(rong)器(qi)(qi)組(zu)。電(dian)(dian)(dian)(dian)(dian)容(rong)器(qi)(qi)組(zu)的(de)(de)投、切操作,就(jiu)會產生過電(dian)(dian)(dian)(dian)(dian)流(liu)(liu)與過電(dian)(dian)(dian)(dian)(dian)壓沖(chong)擊,引起電(dian)(dian)(dian)(dian)(dian)容(rong)器(qi)(qi)損(sun)壞。為保證(zheng)設(she)備(bei)的(de)(de)可靠性(xing),早期(qi)發現電(dian)(dian)(dian)(dian)(dian)容(rong)器(qi)(qi)缺(que)陷,避(bi)(bi)免故障(zhang)擴大(da)(da)(da),需要定期(qi)進行(xing)(xing)檢(jian)測(ce)(ce)。而在現場電(dian)(dian)(dian)(dian)(dian)容(rong)器(qi)(qi)都是(shi)成組(zu)并聯的(de)(de),傳統方法是(shi)將(jiang)電(dian)(dian)(dian)(dian)(dian)容(rong)匯流(liu)(liu)排拆(chai)除,然后用(yong)(yong)老式電(dian)(dian)(dian)(dian)(dian)容(rong)表進行(xing)(xing)測(ce)(ce)量,由(you)于電(dian)(dian)(dian)(dian)(dian)容(rong)器(qi)(qi)組(zu)是(shi)由(you)幾(ji)十至上(shang)百個小電(dian)(dian)(dian)(dian)(dian)容(rong)器(qi)(qi)組(zu)成,要拆(chai)線測(ce)(ce)量電(dian)(dian)(dian)(dian)(dian)容(rong)量的(de)(de)工作量很大(da)(da)(da),而且經常拆(chai)線會使得螺絲滑牙或(huo)沒有(you)(you)上(shang)緊而留下**隱患(huan),也容(rong)易造成電(dian)(dian)(dian)(dian)(dian)容(rong)的(de)(de)二次損(sun)壞。因此,非常期(qi)望有(you)(you)一種測(ce)(ce)試儀器(qi)(qi)不用(yong)(yong)拆(chai)線就(jiu)能(neng)測(ce)(ce)量各個小電(dian)(dian)(dian)(dian)(dian)容(rong)器(qi)(qi)的(de)(de)電(dian)(dian)(dian)(dian)(dian)容(rong)量,減(jian)輕檢(jian)修(xiu)人員的(de)(de)負擔,提高檢(jian)修(xiu)工作的(de)(de)效率(lv),提高配電(dian)(dian)(dian)(dian)(dian)網運(yun)行(xing)(xing)的(de)(de)**性(xing)。
針對現(xian)場的(de)(de)實(shi)際情況,我公(gong)司經過攻關,*終(zhong)研制出一種(zhong)利用新試驗方法進(jin)行(xing)測量(liang)的(de)(de)儀(yi)(yi)器(qi)(qi)(qi)(qi),這就是(shi)三(san)相電(dian)容(rong)(rong)(rong)電(dian)感測試儀(yi)(yi)。該儀(yi)(yi)器(qi)(qi)(qi)(qi)可以在(zai)不拆(chai)線(xian)的(de)(de)狀態(tai)下,測量(liang)成組(zu)并聯(lian)電(dian)容(rong)(rong)(rong)器(qi)(qi)(qi)(qi)的(de)(de)單相電(dian)容(rong)(rong)(rong)或各種(zhong)組(zu)合連(lian)接(jie)類(lei)型的(de)(de)三(san)相電(dian)容(rong)(rong)(rong)器(qi)(qi)(qi)(qi),同時(shi)也(ye)能夠(gou)測量(liang)各種(zhong)電(dian)抗器(qi)(qi)(qi)(qi)的(de)(de)電(dian)感,本(ben)儀(yi)(yi)器(qi)(qi)(qi)(qi)還能測量(liang)工(gong)頻(pin)狀況下的(de)(de)電(dian)流(liu),該儀(yi)(yi)器(qi)(qi)(qi)(qi)接(jie)線(xian)方便,操作簡單,減輕了檢修人員(yuan)的(de)(de)工(gong)作負擔,大大提高了現(xian)場的(de)(de)測試效率,為電(dian)網的(de)(de)正常運行(xing)提供(gong)了**保障。
二、WBDG-2000電容(rong)電感(gan)試驗儀功(gong)能特點
本儀器可在不拆線情況(kuang)下(xia)測量成組(zu)并聯(lian)電(dian)(dian)(dian)容器的(de)單個單相電(dian)(dian)(dian)容及(ji)同時測量各(ge)種連接類型的(de)三(san)(san)相電(dian)(dian)(dian)容,同時本儀器也能測量各(ge)種電(dian)(dian)(dian)抗器的(de)電(dian)(dian)(dian)感量,還可以做為工頻電(dian)(dian)(dian)流測試(shi)儀使(shi)用(yong)(yong)(yong),一(yi)機三(san)(san)用(yong)(yong)(yong),滿足現場的(de)多(duo)種使(shi)用(yong)(yong)(yong);
測量時本儀(yi)器顯示(shi)測量電(dian)容(rong)值或電(dian)感值的同時還可(ke)以(yi)顯示(shi)測量的電(dian)壓、電(dian)流、功率(lv)、頻率(lv)、阻抗、相位角(jiao)等數據,以(yi)便(bian)更好(hao)的分析試品的好(hao)壞;
儀器采用240×128大(da)屏(ping)幕(mu)帶背光的液(ye)晶顯示(shi),白天夜間均能清晰觀察,中文菜(cai)單提(ti)示(shi),操作簡便;
儀(yi)器(qi)內(nei)置(zhi)大容(rong)量非易失性存(cun)儲(chu)器(qi):可存(cun)儲(chu)50組測量數據;
儀器(qi)內置高精度(du)實(shi)時(shi)時(shi)鐘(zhong)功(gong)能:可進(jin)行日期及時(shi)間校準;
儀器自(zi)帶高速微型熱敏打(da)(da)印(yin)機:可打(da)(da)印(yin)測量及歷(li)史數據;
儀(yi)器(qi)試驗(yan)電源過流保(bao)護功能(neng):電源輸出短路不會損壞儀(yi)器(qi)。
三、WBDG-2000電容電感試(shi)驗儀技術指標
輸出電(dian)壓 ~2V, ~20V
輸出(chu)電(dian)流: ≤10A
測量范(fan)圍
電容(rong):0.1uF~2000uF
電感:0.1mH~10H
電流:1mA~10A
電壓: 0 ~25V
測量(liang)精度(du)
電(dian)容:±(1%+2字(zi))
電(dian)感:±(1%+5字)
電流:±(1%+2字)
電壓(ya):±(1%+2字(zi))
外形(xing)尺寸 350mm×230mm×190mm
儀(yi)器(qi)重量 8kg
四(si)、WBDG-2000電容電感(gan)試驗(yan)儀使(shi)用條件(jian)
環境溫度 -10℃~50℃
環境濕度 ≤85%RH
工作電源 AC220V±10%
電源頻率 50±1Hz
儀器功(gong)率 200W
五、WBDG-2000電容電感試驗儀面板介紹
Ua、Ub、Uc、Uo:測試(shi)線電(dian)源電(dian)壓輸出端;
ua、ub、uc、 uo :測試線(xian)采樣電壓引入(ru)端;
Ia、Ib、Ic:電流鉗接線引入(ru)端;
電(dian)源開(kai)關:接通和斷(duan)開(kai)交流(liu)電(dian)源;
FUSE
: 保險盒(he)
:儀器接地(di)端子
液 晶
屏(ping):顯(xian)示操作提示及測量數據
鍵 盤(pan):儀器各種功能的操作
打 印(yin)
機:打印(yin)各種測量數據
六、操(cao)作(zuo)說明
當儀(yi)器按要求接好測試線(xian)及電(dian)源(yuan)線(xian)后(hou),打開(kai)電(dian)源(yuan)開(kai)關,液晶顯示開(kai)機(ji)界面,如下圖:
延時(shi)兩三秒鐘后液(ye)晶顯示(shi)主(zhu)菜單,如下圖(tu)所示(shi):
如果需要電(dian)容(rong)(rong)測(ce)試(shi),在(zai)主菜(cai)單畫面下,按↑ ↓鍵,選(xuan)擇(ze) 電(dian)容(rong)(rong)測(ce)試(shi) 后,按 確(que)認(ren) 鍵,進入(ru)電(dian)容(rong)(rong)測(ce)量設定畫面,如下圖所示:
在(zai)電(dian)容(rong)測量界面,按↑ ↓鍵選擇被測電(dian)容(rong)類型(xing),按 確認 鍵進入如下(xia)顯示(shi)界面(選擇單相(xiang)電(dian)容(rong)):
經過幾秒鐘(zhong)時間,顯示(shi)測試結(jie)果如(ru)下圖所示(shi):
如(ru)果要打(da)印數據,請(qing)按打(da)印鍵,存儲數據請(qing)按F1鍵(jian),如果(guo)還需測(ce)量(liang)同(tong)相電(dian)壓下的其他單相電(dian)容,可(ke)按返回鍵(jian)返回電(dian)容測(ce)試界面(mian),將電(dian)流鉗夾(jia)到被測(ce)電(dian)容上,按確認鍵(jian)重新測(ce)量(liang)。
在電容(rong)(rong)測(ce)量界面,如(ru)(ru)果要測(ce)試三(san)相(xiang)電容(rong)(rong),首先根據連接類型將所(suo)(suo)需測(ce)試線連接好,請(qing)按↑
↓鍵選擇(ze)被測(ce)三(san)相(xiang)電容(rong)(rong)類型,比如(ru)(ru)如(ru)(ru)果選擇(ze)三(san)相(xiang)△型電容(rong)(rong)測(ce)試,屏幕顯示的界面如(ru)(ru)下圖所(suo)(suo)示:
按 確認
鍵進入如下顯示界面:
經過一段時間,顯(xian)示測試結果如下圖所示:
存儲數據請按F1鍵(jian),打(da)印(yin)數據請按(an)打(da)印(yin)鍵(jian),按(an)返回(hui)鍵(jian)返回(hui)電容(rong)測(ce)試(shi)界面,其(qi)他連接(jie)類(lei)型的三(san)相電容(rong)測(ce)試(shi)方法與(yu)上類(lei)同。按(an)返回(hui)鍵(jian)或(huo)復位鍵(jian)可(ke)回(hui)到主菜單。
電(dian)感(gan)測試及電(dian)流測試與(yu)電(dian)容(rong)測試操作類同,不再重復介紹。
如果(guo)需(xu)要設置(zhi)時(shi)間可按← →及↑ ↓鍵,選中時(shi)間設置(zhi),按確認鍵進入(ru)設置(zhi)界面如下:
按(an)(an)(an)← →改變(bian)光標(biao)前后位(wei)置(zhi),按(an)(an)(an)↑
↓鍵(jian)改變(bian)光標(biao)處當前值的大小,設(she)置(zhi)完成可按(an)(an)(an)返回鍵(jian)或復位(wei)鍵(jian)返回主菜單。
參數設(she)置(zhi)為(wei)出廠(chang)校準(zhun)時(shi)(shi)設(she)置(zhi),建議客戶(hu)不得(de)改變其設(she)置(zhi)數據,否(fou)則會造成測試數據的不準(zhun)。如(ru)果需要重新更改,必須在(zai)本(ben)公(gong)司(si)技術人(ren)員指導(dao)下進行,并且(qie)先要記錄下更改前(qian)的設(she)定值(zhi)(zhi),以便(bian)設(she)置(zhi)失敗時(shi)(shi)能(neng)夠恢(hui)復初始(shi)值(zhi)(zhi)。
如果想查(cha)詢已存儲的記錄,可在(zai)主菜(cai)單下選擇查(cha)詢記錄,按確認鍵(jian)進入顯示(shi)如下:
按↑ ↓鍵(jian)查詢所(suo)需記錄(lu)(lu),按打印鍵(jian)可打印當前記錄(lu)(lu),如果要刪除記錄(lu)(lu),可按F2鍵(jian)進行刪除(chu),刪除(chu)完成后所(suo)有記錄均清零。按返(fan)回(hui)鍵(jian)或(huo)復位鍵(jian)可(ke)返(fan)回(hui)主菜(cai)單。
測試(shi)數據中各(ge)符號(hao)的含義:
⑴、I:被測電容(抗)器(qi)的電流有效值,單位為(wei)A(安(an)培(pei));
⑵、U:被測電(dian)容(抗)器的(de)電(dian)壓有(you)效(xiao)值,單位為V(伏特);
⑶、P:被測(ce)電容(抗)器的有(you)功功率(lv)有(you)效值,單位為W(瓦);
⑷、F:輸出電源的當前頻(pin)率(lv),單位為Hz(赫茲);
⑸、Rc:被測(ce)電容(rong)器(qi)的容(rong)抗,單(dan)位為Ω(歐姆);
⑹、Rl:被測電抗器的感(gan)抗,單(dan)位為(wei)Ω(歐姆);
⑺、Rz:被測試品的阻抗,單位為Ω(歐姆(mu));
⑻、C:被測試電(dian)容器的(de)電(dian)容值,單位(wei)為uF(微法);
⑼、Cab:被測三相(xiang)電(dian)容(rong)器的AB相電容值,單位(wei)為uF(微法);
⑽、Cbc:被測(ce)三相電容器的BC相電容值,單位為(wei)uF(微法(fa));
⑾、Cca:被測三相電容器的CA相電容值(zhi),單(dan)位為uF(微法);
⑿、Ca:被測三(san)相(xiang)電容器的(de)A相電容值,單位(wei)為uF(微法);
⒀、Cb:被(bei)測(ce)三(san)相電容器的B相電容(rong)值,單位為uF(微法);
⒁、Cc:被測三相電容器的C相電容值(zhi),單位為uF(微法);
⒂、Cz:被測三相電容器總的電容值,單位為uF(微法);
⒃、L:被測(ce)電抗(kang)器的當前(qian)測(ce)量電感(gan)值,單位為(wei)H(亨);
⒄、Ф:被測試(shi)品(pin)的(de)電壓與電流之間的(de)相位(wei)角,單位(wei)為 o(度)
七、測(ce)試(shi)接線
單相(xiang)電容(rong)的(de)測量:
單相電容測試(shi)時,將紅測試(shi)線一端接在Ua、ua上,另一(yi)端(duan)測試鉗接在(zai)一(yi)條(tiao)母(mu)線上,黑測試線一(yi)端(duan)接在(zai)Uo、uo上(shang),另(ling)一(yi)端(duan)接在另(ling)一(yi)條母線上(shang),鉗形CT輸出線接到儀器Ia端,鉗形CT夾在與紅測試(shi)鉗相連母線的電容引入端,連線時(shi)要注意電流鉗上(shang)標有“P”的一端朝向電容方(fang)向夾(jia)在電容器上,否則(ze)測試的相位(wei)角不正(zheng)確。
如果電(dian)容(rong)器(qi)組有多個(ge)單相電(dian)容(rong)需要(yao)測(ce)試(shi),可以在(zai)測(ce)試(shi)完**個(ge)電(dian)容(rong)值后按返回鍵(jian),電(dian)壓(ya)測(ce)試(shi)線不(bu)用動(dong),直接將測(ce)試(shi)電(dian)流的電(dian)流鉗(qian)打開然后夾到(dao)下一個(ge)電(dian)容(rong)上按確認鍵(jian)進行(xing)測(ce)試(shi),這(zhe)樣(yang)可大(da)大(da)的提高測(ce)試(shi)速(su)度,這(zhe)才是(shi)本(ben)儀器(qi)的*大(da)特色(se)。
(2)三相△型電容的測量:
圖13是三相△形電容測(ce)(ce)量(liang)接(jie)線方法(fa),測(ce)(ce)量(liang)線由儀器測(ce)(ce)量(liang)輸出端(duan)按顏色(se)對應接(jie)好,將紅色(se)夾子夾在母線排A相上、綠色夾子夾在母線B相上,紅色夾(jia)子夾(jia)在母線C上,然后將三個電流測量線分別對(dui)應(ying)插在儀器Ia、Ib、Ic上擰緊、鉗形(xing)傳(chuan)感(gan)器對應套在高壓電容器組(zu)A相、B相、C相引入線上,要(yao)注意各鉗(qian)型電(dian)流互感器的方向是否正確,否則會造成所測電(dian)容的相位(wei)角(jiao)錯誤。
(3)三(san)相Y型電容的測(ce)量:
三相Y型(xing)電容(rong)與△形聯(lian)接電容(rong)器的接線方法一樣,只(zhi)是測量時選擇三相(xiang)Y型(xing)電容測量(liang)。這(zhe)里不再做具體介紹。
(4)三相Yn型電容的測量:
圖14是(shi)三相(xiang)Yn型(xing)電容測量(liang)(liang)接線方法,測量(liang)(liang)線由儀器測量(liang)(liang)輸(shu)出(chu)端按(an)顏(yan)色對應接好(hao),將紅色夾子夾在母線排(pai)A相上(shang)、綠色(se)夾子夾在母線B相上,紅色夾子夾在母線C上,黑(hei)色夾(jia)子夾(jia)在(zai)母線N上,然后將三個電(dian)流測量線分別對(dui)應插在儀器Ia、Ib、Ic上擰緊、鉗形(xing)傳感器(qi)(qi)對應(ying)套在高壓電容(rong)器(qi)(qi)組A相、B相、C相引(yin)入線(xian)上,要(yao)注意各鉗(qian)型(xing)電(dian)流互(hu)感(gan)器(qi)的方向是否正(zheng)確,否則(ze)會造成(cheng)所測(ce)電(dian)容(rong)的相位(wei)角錯誤(wu)。
(5)三相III型電容的測量:
圖15為(wei)三相Ⅲ型電(dian)容器測(ce)(ce)量接線(xian)(xian)方法,測(ce)(ce)量線(xian)(xian)由儀器測(ce)(ce)量輸出(chu)端(duan)按顏色(se)對應插好,將黃色(se)夾(jia)(jia)子夾(jia)(jia)在母線(xian)(xian)排A相上,將綠(lv)色夾子夾在母線排(pai)B相上,將(jiang)紅色夾(jia)子夾(jia)在母(mu)線排(pai)C相上,黑色夾子(zi)夾在A’線上(shang),將A‘B’C‘短接,然后將(jiang)三個電流(liu)測(ce)量線(xian)分(fen)別對(dui)應插在儀器Ia、Ib、Ic上擰緊、鉗形傳感器對應(ying)套在高壓(ya)電(dian)容器組(zu)A相、B相(xiang)、C相引入線(xian)上(shang)。
(6)電抗器電感的測量(liang):
電抗器(qi)電感(gan)測試時,將紅測試線一端接在Ua、ua上(shang),另一(yi)端(duan)測試鉗接在電抗器一(yi)引出(chu)端(duan)上(shang),黑測試線一(yi)端(duan)接在Uo、uo上,另一(yi)端接在電抗器另一(yi)引出端上,鉗形CT輸出線接到儀器Ia端,鉗形CT夾在(zai)與紅測試鉗相連電抗器引出端,連線時要(yao)注意電流(liu)鉗上(shang)標(biao)有“P”的一端朝(chao)向(xiang)電(dian)抗器方向(xiang)夾在(zai)電(dian)抗器上(shang),否則測試的相位角不正確。
八、產品(pin)成套性:
部 件
|
數量
|
部(bu) 件
|
數量
|
電容(rong)電感測試儀主機
|
1臺
|
鉗形(xing)電流傳(chuan)感器
|
3個(ge)
|
測試線
|
1套(tao)
|
5A保險管250V
|
2個
|
儀器電源線
|
1根
|
產品出廠合格證
|
1張
|
儀器使用說明書
|
1本
|
接地線
|
1條(tiao)
|
保修卡(ka)
|
1張
|
打印(yin)紙
|
2卷
|
|
|
裝箱單
|
1張
|
用戶收到(dao)儀(yi)器(qi)后,按(an)照儀(yi)器(qi)的成(cheng)套說(shuo)明,開箱檢查(cha)是否相符,核對上述內容,若發生缺少(shao),請(qing)立即與本公司(si)聯系。
九、注意(yi)事項
8.1使用本儀(yi)器前(qian)請仔細閱(yue)讀使用說(shuo)明書(shu),檢查接線無誤(wu)、接地良好。
8.2高(gao)(gao)精(jing)度電流鉗為本儀器測(ce)量的關鍵部件,受損后(hou)對(dui)測(ce)試數據有很(hen)大的影響,在使用過程中需謹慎,要(yao)輕拿輕放,不能從(cong)高(gao)(gao)空(kong)掉(diao)落或者摔碰。
8.3在(zai)測量完畢并退出測量狀態后,關閉儀器電(dian)源,方可進行接線拆除。
8 .4如出現無法解決的(de)問(wen)題(ti),請及(ji)時(shi)與本公司取得(de)聯系。
十、售后服(fu)務
儀(yi)器自購買之日起(qi)一(yi)年內,屬產(chan)品質量問(wen)題免費包修包換,終身提供維修和技術服務。如發(fa)現(xian)儀(yi)器有異常情況或故障請與(yu)公(gong)司及時(shi)聯系,以便(bian)為(wei)您安排(pai)*便(bian)捷的處理(li)方案(an)。