一、WBYD2000串聯諧振基本原理
耐壓(ya)試(shi)驗(yan)是利用(yong)電(dian)(dian)(dian)(dian)抗器(qi)的(de)(de)(de)電(dian)(dian)(dian)(dian)感與被試(shi)品(pin)電(dian)(dian)(dian)(dian)容(rong)組成LC串聯回路,調(diao)節變頻(pin)電(dian)(dian)(dian)(dian)源輸(shu)出(chu)的(de)(de)(de)電(dian)(dian)(dian)(dian)壓(ya)頻(pin)率,在被試(shi)品(pin)上(shang)獲(huo)得(de)高電(dian)(dian)(dian)(dian)壓(ya),是當前高電(dian)(dian)(dian)(dian)壓(ya)試(shi)驗(yan)的(de)(de)(de)一種(zhong)新方(fang)法(fa),深受(shou)專家好(hao)評,在國內(nei)外已經得(de)到(dao)廣泛的(de)(de)(de)使用(yong)。
根據諧振(zhen)原理,我們知道當(dang)電(dian)抗(kang)器L的感(gan)抗(kang)值Xl與回路中(zhong)的容抗(kang)值Xc相等(deng)時,回路達到諧振(zhen)狀態,此時回路中(zhong)僅回路電(dian)阻R消耗有功功率,而無功功率則在電(dian)抗(kang)器與試(shi)品電(dian)容之間來回振(zhen)蕩,從而在試(shi)品上產生高(gao)壓。
二、WBYD2000串聯諧振系統構成
全(quan)套試(shi)驗系統由(you)調頻電源主機、電抗(kang)器(qi)、分壓器(qi)、激勵變壓器(qi)和(he)補償電容器(qi)(可選器(qi)件)組(zu)成(cheng),接入被(bei)試(shi)品后組(zu)成(cheng)一個(ge)諧振系統進行交流耐(nai)壓實驗。
主機: 就是一臺幅值和(he)頻(pin)(pin)率可調的(de)正(zheng)弦波(bo)交流調頻(pin)(pin)電(dian)源,給諧振回路提(ti)供激勵(li)源,同時提(ti)供電(dian)壓顯(xian)(xian)示(shi)、電(dian)流顯(xian)(xian)示(shi)、計時、保護、報警(jing)等功能。
電抗(kang)器:就是(shi)一(yi)個大電感線圈,與(yu)被試(shi)品(相當于電容)構成回路,可配置電抗(kang)器多節電抗(kang)器,使用時(shi)通過不同(tong)的串(chuan)聯(lian)、并(bing)聯(lian)組合、實現不同(tong)的電感量以(yi)適用不同(tong)的試(shi)驗(yan)條件。
分壓(ya)器:內部(bu)通過電(dian)容器分壓(ya),從(cong)試品上高電(dian)壓(ya)分得低(di)電(dian)壓(ya)供主機測(ce)量、控制使用。
勵(li)磁變壓器:隔離主機電源與諧振回路(lu)電源,并升高主機的輸(shu)出(chu)電壓。
補(bu)償(chang)(chang)電(dian)容(rong)器:當試(shi)(shi)品電(dian)容(rong)量很小時,如果要(yao)實現(xian)系(xi)統諧振可能要(yao)求的(de)(de)電(dian)源頻率(lv)超出試(shi)(shi)驗標(biao)準的(de)(de)規定,可在試(shi)(shi)品上(shang)并聯一個補(bu)償(chang)(chang)電(dian)容(rong),以實現(xian)試(shi)(shi)驗要(yao)求,稱此電(dian)容(rong)器為補(bu)償(chang)(chang)電(dian)容(rong)器。
三、WBYD2000串聯諧振主要技術性能
功率電源電壓(ya):AC380V±10%、50Hz;
儀(yi)器電源:220V±10%、50Hz;
諧振(zhen)輸出容量:200kVA;
儀器(qi)額定電壓:0~200kV;
輸出頻率范圍:30~300Hz;
輸出(chu)電壓波(bo)形(xing)(xing):正弦波(bo),波(bo)形(xing)(xing)畸(ji)變率<0.5%;
頻率調節(jie)靈(ling)敏度(du)(du):0.1Hz,不穩定度(du)(du)≤0.05%;
系統噪聲:≤60db;
9、系統(tong)測量精度:<1級;
10.輸出電壓不穩定:<0.5%;
11.保護響應時間:1us;
12.電(dian)感非線性度:≤0.05%;;
13.滿功率輸出下,連(lian)續(xu)工作時間為60min
14.環(huan)境溫度:-15℃~+50℃;
15.相對濕度:≤90%RH;
16.海拔高度:≤2000米。
四、WBYD2000串聯諧振面板及部件名稱
五、WBYD2000串聯諧振操作步驟
1、正(zheng)確連線,檢查無誤后方可送電。
必(bi)要時工作電(dian)源的(de)跳過現場漏電(dian)保安器,以免不(bu)必(bi)要的(de)跳閘。
2、打開電(dian)源開關,主機(ji)開始工作,液(ye)晶屏顯示版(ban)權頁,該(gai)頁標明本裝置的(de)軟件版(ban)本號。
觸按確認鍵,進入(ru)系統(tong)菜(cai)單(dan),該主菜(cai)單(dan)下有:試(shi)驗方案、開(kai)始試(shi)驗、試(shi)驗幫助、系統(tong)設置、實用工具和(he)試(shi)驗記(ji)錄等六個(ge)子菜(cai)單(dan)項。
3、 系(xi)(xi)統設(she)置菜(cai)單(dan)(dan)下有電(dian)抗器(qi)電(dian)感、日期(qi)時間設(she)置和采(cai)樣系(xi)(xi)數設(she)置等三個子(zi)菜(cai)單(dan)(dan)項(xiang)。按上下鍵(jian)(jian),上下移動(dong)光標系(xi)(xi)統參數設(she)置菜(cai)單(dan)(dan)項(xiang),觸(chu)按確定(ding)鈕后,進入系(xi)(xi)統參數設(she)置菜(cai)單(dan)(dan),可以分(fen)別設(she)定(ding)電(dian)抗器(qi)的(de)電(dian)感—H、-年-月-日、-時-分(fen)-秒(miao)和電(dian)壓和電(dian)流的(de)采(cai)樣系(xi)(xi)數也就是(shi)采(cai)樣倍率,設(she)定(ding)完成后,觸(chu)按返(fan)還鍵(jian)(jian)返(fan)回上**菜(cai)單(dan)(dan)。
電抗器電感量的(de)設(she)定:按(an)確定鍵選擇到此項,按(an)左右鍵移動(dong)光標需(xu)要(yao)改(gai)變的(de)數(shu)位,按(an)上(shang)下鍵改(gai)變數(shu)值,達(da)到所要(yao)達(da)到的(de)數(shu)值按(an)確定鍵確認(ren)。
日期時(shi)間的設定(ding):按(an)確(que)定(ding)鍵(jian)選(xuan)擇到此項(xiang),按(an)左右(you)鍵(jian)移動光(guang)標需要改變(bian)的數位(wei),按(an)上下鍵(jian)改變(bian)數值,按(an)照所要設置(zhi)的年月(yue)日時(shi)間數值按(an)確(que)定(ding)鍵(jian)確(que)認。
采(cai)樣(yang)(yang)系(xi)數(shu)的(de)設(she)(she)定(ding):按(an)確定(ding)鍵(jian)選擇到高壓(ya)/電流采(cai)樣(yang)(yang)系(xi)數(shu)項(xiang)(xiang),此項(xiang)(xiang)為電壓(ya)或電流采(cai)樣(yang)(yang)倍率的(de)設(she)(she)定(ding)。一(yi)(yi)般出廠前(qian)設(she)(she)定(ding)好了。如需(xu)修改(gai),要輸入密(mi)碼。(密(mi)碼廠家(jia)與設(she)(she)備一(yi)(yi)起提供一(yi)(yi)般設(she)(she)定(ding)為:188888)
警告:系(xi)(xi)統(tong)默認上(shang)一次(ci)電抗器電感、日期(qi)時間和采(cai)樣系(xi)(xi)數設定(ding)值。如果需改變要重(zhong)新設定(ding)。電抗器電感量設定(ding)值與實際使用的(de)電抗器電感量不(bu)(bu)對(dui),會(hui)(hui)導致試驗(yan)報告中的(de)被試品電容量不(bu)(bu)準(zhun)。其他并不(bu)(bu)會(hui)(hui)影響。采(cai)樣系(xi)(xi)數設置(zhi)不(bu)(bu)正確,會(hui)(hui)導致顯(xian)示電壓電流(liu)不(bu)(bu)準(zhun)將很有(you)可能會(hui)(hui)對(dui)被試品或試驗(yan)設備造成損壞。
4、試驗方(fang)案(an)菜(cai)單下有(you)預(yu)置(zhi)保護電流(liu)、找頻(pin)(pin)起(qi)(qi)(qi)始(shi)頻(pin)(pin)率、找頻(pin)(pin)結(jie)束頻(pin)(pin)率、預(yu)定(ding)(ding)起(qi)(qi)(qi)始(shi)功率四(si)個子(zi)菜(cai)單項,分(fen)別設定(ding)(ding)本次試驗的(de)保護電流(liu)、找頻(pin)(pin)起(qi)(qi)(qi)始(shi)頻(pin)(pin)率、找頻(pin)(pin)結(jie)束頻(pin)(pin)率、輸出起(qi)(qi)(qi)始(shi)功率,全部設定(ding)(ding)完成后,觸按(an)返還(huan)鍵進入預(yu)置(zhi)試驗電壓和(he)預(yu)置(zhi)試驗時間設置(zhi)菜(cai)單。
可以分3段(duan)時(shi)(shi)間(jian)設(she)置試驗電壓(ya)(ya)和試驗時(shi)(shi)間(jian), 實際試驗時(shi)(shi),若設(she)定(ding)為(wei)自動試驗, 裝置將按(an)(an)設(she)定(ding)的3段(duan)電壓(ya)(ya)及時(shi)(shi)間(jian),按(an)(an)順序分別加壓(ya)(ya), 全部完成后自動退出.
如(ru)果**段電(dian)壓(ya)設(she)為(wei)0, 或時(shi)間設(she)為(wei)0, 那么執行完**段試驗(yan)電(dian)壓(ya)加壓(ya)后退(tui)出試驗(yan), 只(zhi)加壓(ya)**段設(she)定的電(dian)壓(ya).
如(ru)果第三(san)段(duan)電(dian)壓設為0, 或(huo)時間設為0, 不執行(xing)第三(san)段(duan)加(jia)壓.
試驗(yan)(yan)方案(an)設(she)置的(de)(de)設(she)定:在試驗(yan)(yan)電壓項中,按(an)確定單鈕,移動左右光(guang)標(biao)到需(xu)要改變的(de)(de)數(shu)位,按(an)上(shang)下(xia)單鈕以改變當前(qian)數(shu)位的(de)(de)數(shu)值(zhi)大小,觸按(an)返(fan)回(hui)鈕完成(cheng)當前(qian)數(shu)位的(de)(de)數(shu)值(zhi)設(she)定,依次(ci)(ci)選擇下(xia)一項數(shu)值(zhi)的(de)(de)設(she)定,直至分(fen)別完成(cheng)試驗(yan)(yan)時間、起(qi)(qi)始頻率(lv)、起(qi)(qi)始功率(lv)的(de)(de)設(she)置,方可完成(cheng)本次(ci)(ci)試驗(yan)(yan)的(de)(de)試驗(yan)(yan)方案(an)設(she)置的(de)(de)設(she)定。
出廠默(mo)認值:試驗(yan)電(dian)壓(ya) 20kV、加(jia)壓(ya)時間 2min、激勵(li)強度 2%、輸出電(dian)流20A、頻(pin)率范圍30-300Hz。
5、實用工(gong)具(ju)菜(cai)單下有
頻率計(ji)算(suan):在實驗前可對(dui)諧振頻率進行(xing)計(ji)算(suan)。只需輸入具體(ti)參與試(shi)驗的電感、電容值并按確(que)定鍵試(shi)驗頻率即直接生成。
6、開始試驗菜(cai)(cai)單(dan)(dan)下有自(zi)動(dong)試驗模式(shi)和手(shou)動(dong)試驗模式(shi)兩種子菜(cai)(cai)單(dan)(dan)可(ke)供選擇。
按確認鍵進(jin)入所選試驗步驟.
自(zi)動(dong)(dong)試(shi)驗模式的操作:選中自(zi)動(dong)(dong)試(shi)驗模式后,觸按菜單鈕進入正在(zai)(zai)自(zi)動(dong)(dong)尋找(zhao)諧振(zhen)點菜單項,裝(zhuang)置在(zai)(zai)設(she)定(ding)(ding)的頻率(lv)范(fan)圍(wei)內(nei)自(zi)動(dong)(dong)尋找(zhao)諧振(zhen)點(如果被(bei)試(shi)品電(dian)容C和(he)電(dian)抗器(qi)電(dian)感L的實際諧振(zhen)頻率(lv)不(bu)在(zai)(zai)設(she)定(ding)(ding)的頻率(lv)范(fan)圍(wei)內(nei),將找(zhao)不(bu)到(dao)諧振(zhen)點,此時根據需要調(diao)整頻率(lv)范(fan)圍(wei)或調(diao)整被(bei)試(shi)品回路(lu)的LC參數)。當找(zhao)到(dao)諧振(zhen)點時,會(hui)有聲音提示。
找到(dao)諧振點(dian)后,裝置(zhi)自動進入正在自動升壓菜單項,當升到(dao)試驗電(dian)壓設定的電(dian)壓時,裝置(zhi)停止加壓。
當裝置升到試(shi)(shi)(shi)驗(yan)(yan)電壓設定的電壓時(shi)(shi),設備停止加(jia)壓,自(zi)動進(jin)入正在加(jia)壓試(shi)(shi)(shi)驗(yan)(yan)菜(cai)單項,并自(zi)動記錄試(shi)(shi)(shi)驗(yan)(yan)的加(jia)壓時(shi)(shi)間(jian),當加(jia)壓時(shi)(shi)間(jian)到達(da)設定時(shi)(shi)間(jian)時(shi)(shi),設備逐步降壓退出試(shi)(shi)(shi)驗(yan)(yan),完成本次試(shi)(shi)(shi)驗(yan)(yan),進(jin)入試(shi)(shi)(shi)驗(yan)(yan)結束(shu)菜(cai)單項。并可選(xuan)擇保存試(shi)(shi)(shi)驗(yan)(yan)數據或打印試(shi)(shi)(shi)驗(yan)(yan)數據。
試驗時間的一(yi)行顯示(shi)末端,會(hui)顯示(shi)[一(yi)段(duan)]或(huo)[二段(duan)]或(huo)[三段(duan)]字樣(yang),表示(shi)當(dang)前正在進行的加壓(ya)試驗是預置(zhi)的一(yi)段(duan),二段(duan)或(huo)三段(duan).
手動試驗模(mo)式的操作:選中手動試驗模(mo)式后觸按(an)(an)確定鈕,進入正在試驗菜單項(xiang);手動按(an)(an)調頻(pin)鈕,對(dui)應的光標隨(sui)之(zhi)改變(bian)到輸出頻(pin)率(lv)(lv)項(xiang),可以(yi)通過上(shang)下(xia)左右鍵改變(bian)頻(pin)率(lv)(lv)大小使其試驗電(dian)壓(ya)(ya)逐步升(sheng)高(gao),當(dang)升(sheng)到*高(gao)電(dian)壓(ya)(ya)時,繼續向上(shang)或向下(xia)調整頻(pin)率(lv)(lv)按(an)(an)鈕,直至試驗電(dian)壓(ya)(ya)開(kai)始下(xia)降;這(zhe)時反調頻(pin)率(lv)(lv),試驗電(dian)壓(ya)(ya)又(you)逐步回(hui)(hui)升(sheng),上(shang)下(xia)回(hui)(hui)調頻(pin)率(lv)(lv),從(cong)頻(pin)率(lv)(lv)的高(gao)位到低位逐位調整*高(gao)電(dian)壓(ya)(ya)值時的頻(pin)率(lv)(lv)就是當(dang)前的諧振頻(pin)率(lv)(lv)。
找(zhao)到(dao)諧振(zhen)點后,手動按電(dian)(dian)壓(ya)鈕,光標到(dao)了輸出功率,隨(sui)之按上(shang)下鍵增加(jia)(jia)輸出功率,試驗(yan)電(dian)(dian)壓(ya)也逐步升(sheng)高,當(dang)升(sheng)到(dao)試驗(yan)電(dian)(dian)壓(ya)設(she)定(ding)電(dian)(dian)壓(ya)值(zhi)時(shi)(shi),裝置停止加(jia)(jia)壓(ya),并(bing)有(you)屏幕顯(xian)示(shi)提示(shi)和聲音提示(shi);自動進入正在加(jia)(jia)壓(ya)試驗(yan)菜(cai)單項,并(bing)自動記錄(lu)試驗(yan)的(de)加(jia)(jia)壓(ya)時(shi)(shi)間(jian),當(dang)到(dao)達加(jia)(jia)壓(ya)時(shi)(shi)間(jian)設(she)定(ding)時(shi)(shi)間(jian)時(shi)(shi),設(she)備逐步降壓(ya)退(tui)出試驗(yan),完成本(ben)次試驗(yan),進入試驗(yan)結束菜(cai)單項。
注(zhu)意:在調(diao)節頻(pin)率調(diao)整鈕(niu)(niu)的過(guo)(guo)程中,觸(chu)按左右(you)鈕(niu)(niu),可以(yi)改變(bian)頻(pin)率調(diao)節的速度實(shi)現粗細(xi)調(diao)的切(qie)換。在調(diao)節電壓(ya)調(diao)整鈕(niu)(niu)的過(guo)(guo)程中,向下觸(chu)按左右(you)鈕(niu)(niu),可以(yi)改變(bian)電壓(ya)的升降的速度實(shi)現粗細(xi)調(diao)的切(qie)換。觸(chu)按調(diao)頻(pin)、調(diao)壓(ya)鈕(niu)(niu),實(shi)現調(diao)頻(pin)與調(diao)壓(ya)間的切(qie)換。
7、進入試驗記錄查詢菜單項,查詢以(yi)往(wang)和當前試驗數據(ju)。選(xuan)(xuan)擇上(shang)下鍵(jian)翻看前一組(zu)(zu)數據(ju)后一組(zu)(zu)數據(ju);選(xuan)(xuan)擇左(zuo)右鍵(jian)可(ke)選(xuan)(xuan)擇打印(yin)或刪除當前頁的內容(rong)。
125/456為試(shi)驗數(shu)(shu)據(ju)庫指針,分子是(shi)試(shi)驗數(shu)(shu)據(ju)的(de)在數(shu)(shu)據(ju)庫的(de)順(shun)序數(shu)(shu),分母是(shi)當前的(de)數(shu)(shu)據(ju)總數(shu)(shu),*多可(ke)儲存999組試(shi)驗數(shu)(shu)據(ju)。
8、裝置和試(shi)(shi)驗(yan)狀(zhuang)態(tai)菜單提(ti)示(shi):設備(bei)的使用和升壓(ya)和耐(nai)壓(ya)試(shi)(shi)驗(yan)過程中,如果(guo)出現影(ying)響試(shi)(shi)驗(yan)設備(bei)、被(bei)試(shi)(shi)驗(yan)設備(bei)以(yi)及操作人(ren)的**情況(kuang),設備(bei)可能出現自動保護轉臺,并在(zai)屏幕有相應的提(ti)示(shi)。
不能(neng)諧(xie)振:如果諧(xie)振點(dian)不在諧(xie)振頻率設置(zhi)的范圍(wei)內;系統連線(xian)不正確(que)等現象(xiang),裝置(zhi)將找不到諧(xie)振點(dian),這時裝置(zhi)和試驗(yan)狀態菜單中的不能(neng)諧(xie)振項被反白并閃爍。
輸(shu)出(chu)(chu)保(bao)護(hu):如(ru)果裝(zhuang)置的(de)電(dian)源(yuan)輸(shu)出(chu)(chu)電(dian)流(liu)(liu)大于輸(shu)出(chu)(chu)保(bao)護(hu)設定(ding)的(de)電(dian)流(liu)(liu)值(zhi),裝(zhuang)置自(zi)動(dong)保(bao)護(hu),這時裝(zhuang)置和試(shi)驗狀態菜單中的(de)輸(shu)出(chu)(chu)保(bao)護(hu)項被反白并閃爍(shuo)。
試驗中(zhong)止:如果在試驗升壓(ya)或(huo)加壓(ya)過程出現閃絡現象,裝(zhuang)置自(zi)動保(bao)護(hu),這時(shi)裝(zhuang)置和試驗狀態菜單中(zhong)的輸出保(bao)護(hu)項被反白并閃爍。
9、試驗幫助(zhu)內容包(bao)括五大項分(fen)別為:1.版本信息(xi)2.接線(xian)示意3.使(shi)用說明4.常(chang)見問題(ti)5.參(can)考資(zi)料.如(ru)常(chang)見問題(ti)FAQ分(fen)五幅(fu)畫面(mian)顯(xian)示、各種被試品電(dian)力電(dian)纜、變壓器、發電(dian)機電(dian)容參(can)數的查(cha)詢(xun):
接線示意圖:
10、設(she)備(bei)出(chu)廠(chang)(chang)(chang)參數(shu)設(she)置(zhi)是(shi)生產廠(chang)(chang)(chang)家(jia)的出(chu)廠(chang)(chang)(chang)設(she)置(zhi)參術和(he)(he)校(xiao)驗參數(shu),不適當的設(she)置(zhi)和(he)(he)修改會影響設(she)備(bei)性(xing)(xing)能和(he)(he)高壓試驗的**性(xing)(xing),未經廠(chang)(chang)(chang)家(jia)授權密碼(ma),無法修改。
警告(gao):正常試(shi)驗狀態下,按返(fan)回鍵即可中止(zhi)試(shi)驗。中止(zhi)或(huo)結束試(shi)驗后,應分離刀閘(zha)切斷電源。在升壓(ya)(ya)或(huo)加壓(ya)(ya)過程中,非緊急情(qing)況,不要按下急停鍵。
六(liu)、本說(shuo)明書的專屬名詞的定義(yi)
自動(dong)試驗:高壓試驗全過(guo)程由主(zhu)機(ji)按程序和預置參數(shu)自動(dong)完成(cheng)。
自動調(diao)諧(xie):調(diao)諧(xie)由(you)主機按程序自動完成,升壓手動完成。
手(shou)動試驗:尋找(zhao)諧振(zhen)點和升壓均(jun)為手(shou)動,通過面板旋(xuan)鈕完(wan)成。
系統參數設(she)置(zhi)是指(zhi)對設(she)備部件參數的(de)設(she)置(zhi)。
試驗參(can)數設置是指(zhi)對(dui)試驗過(guo)程參(can)數的設置。
試(shi)(shi)驗模式選擇(ze)(ze)是指對(dui)試(shi)(shi)驗模式的選擇(ze)(ze)。
試驗(yan)結果查詢是(shi)指(zhi)對試驗(yan)數(shu)據的(de)查詢。
分壓(ya)器變比(bi)是指對分壓(ya)器的分壓(ya)比(bi)設置。
電(dian)抗器電(dian)感(gan)是指對電(dian)抗器電(dian)抗值的(de)設置。
激勵(li)變變比是指對(dui)勵(li)磁變壓器(qi)的變比設(she)置。
設(she)置(zhi)(zhi)電(dian)(dian)壓(ya)是(shi)高壓(ya)試(shi)驗時的保護電(dian)(dian)壓(ya)設(she)置(zhi)(zhi)。
試(shi)驗(yan)電壓(ya)是高壓(ya)試(shi)驗(yan)時的(de)試(shi)驗(yan)電壓(ya)。
加壓時間是(shi)施加試驗(yan)電壓的時間。
激勵(li)強(qiang)度是指(zhi)主機電源(yuan)輸出(chu)的大小。
輸出電流是(shi)主機電源(yuan)的(de)輸出電流。
頻(pin)率范圍(wei)是試(shi)驗的頻(pin)率范圍(wei)。
自動(dong)試驗(yan)模式是指試驗(yan)過程全(quan)部(bu)自動(dong)完成。
自動調諧模式是指自動尋找諧振點后,手動加壓(ya)完成(cheng)試驗。
手動試驗(yan)模(mo)式全部(bu)由人工完成試驗(yan)過程。
未接地線主機(ji)電源(yuan)為接地。
不(bu)能諧振未(wei)能找到諧振點(dian)。
輸出保(bao)護主機電源輸出電流大于整定電流。
試驗中止指在升壓或(huo)加壓過(guo)程裝置自動保護。
設(she)備(bei)出廠(chang)參(can)數設(she)置是廠(chang)家對設(she)備(bei)有關參(can)數的設(she)置。
確認鍵:確認當前操(cao)作。
返回鍵(jian):返回上**菜(cai)單(dan)。
七、變頻電源技術參(can)數:
1.額定輸(shu)出容量(liang):15kvA;
2.儀(yi)器電源:220v±10% 50Hz;
功率(lv)電源:380v±10% 50Hz;
3.額定輸入電流:39.5A;
4.額定(ding)輸(shu)出電壓(ya):0-340v可調(diao)、單相、輸(shu)出電壓(ya)不穩定(ding)度0.05%;
5.額(e)定輸出電流(liu):44A;
6.頻率調節(jie)范(fan)圍:25~320Hz;
7.額定(ding)容量(liang)下連續運行為規定(ding)工作時間下*高溫(wen)升(sheng)≤60K;
8.顯示以下參數:
a.經變頻輸(shu)出的頻率、電(dian)(dian)壓(ya)、電(dian)(dian)流;
b.過壓保(bao)護(hu)電壓值,并可(ke)任意整定,當成套(tao)裝置的輸出(chu)電壓值達到保(bao)護(hu)整定時,可(ke)自動切(qie)除成套(tao)裝置;
c.過流(liu)保(bao)護:當調頻電源的輸出電流(liu)達到保(bao)護整定(ding)值(zhi)時,可自動切除成套裝置;
d.擊穿保護:當高壓側發生對地(di)閃(shan)絡時,可自動切除成套裝置(zhi),裝置(zhi)帶有隔(ge)離裝置(zhi),可確保設備(bei)和人身不受損害;
e.具有全電(dian)壓(ya)(ya)輸出(chu)保(bao)護,在(zai)調壓(ya)(ya)過程中(zhong),一旦調壓(ya)(ya)失(shi)控,調頻電(dian)源立即閉鎖;
9.可實(shi)現以下操作:
a.頻(pin)率(lv)的調節,上升和(he)下(xia)降頻(pin)率(lv)調節分粗調和(he)細調兩種(zhong),并可自(zi)動(dong)尋找試驗諧振點,保證(zheng)諧振頻(pin)率(lv)在整個試驗過程中不(bu)發(fa)生漂(piao)移;
b.帶有設(she)置電壓、設(she)置時(shi)間(jian),電壓自(zi)動上升到設(she)置值(zhi)而停止(zhi)并自(zi)動計時(shi);
c.帶(dai)有各種保護功能的整(zheng)(zheng)定按鈕,可在面板上(shang)對各種保護值進行整(zheng)(zheng)定;
d.帶有手(shou)動試驗功(gong)能和(he)自動試驗功(gong)能;
e.帶(dai)有試驗數據打印功能。
八、勵磁變壓器(qi)技術參數:
1.結構(gou)形式:干式;
2.額定容量:15kVA;
3.輸入電壓:0~340V;
4.輸出電壓:四組并聯3.75KV;四組串聯15KV;二串二并7.5KV;
5.輸出電流(liu):四組(zu)并(bing)聯4A;四組(zu)串(chuan)聯1A;二(er)串(chuan)二(er)并(bing)2A;
6.工作頻率范圍(wei):30~300Hz;
勵磁變壓器的接線端子,如(ru)圖所示:
1.輸出(chu)端尾—與接(jie)(jie)地端連接(jie)(jie)。
2.輸出(chu)端(duan)頭—與(yu)電抗器連接。
3.接地(di)端(duan)—與變(bian)頻電(dian)源、分壓器及被(bei)試品(pin)共同接地(di)。
4.輸入端(duan)—接調頻電源功率(lv)輸出端(duan)。
九(jiu)、諧振電(dian)抗器技(ji)術參數:
額定容(rong)量:55KVA;
額定電壓:55kV;
額定(ding)電流:1.5A;
電 感(gan) 量:160H;
品(pin)質因數:Q≥30
采用環氧(yang)干式。
7.接(jie)線(xian)端了如(ru)圖所示:
a.高壓(ya)側接線端子(zi)—與(yu)被試品高壓(ya)端連(lian)接。
b.低壓側接線端子—與勵(li)磁變(bian)輸(shu)出(chu)端連接。
c.多(duo)(duo)臺(tai)電(dian)抗(kang)器串聯時上節的低(di)壓側與下節高壓側連接。諧(xie)振電(dian)抗(kang)器采用多(duo)(duo)臺(tai)串聯或并聯的連接方式。
8.額(e)定(ding)容量下(xia)連續(xu)運行為規(gui)定(ding)工作時間(jian)下(xia),電(dian)抗器對空(kong)氣的溫升不大于60K;
9.性能及特點(dian):電抗器設計(ji)干(gan)式、環(huan)氧(yang)澆鑄,電抗器可以自由方便疊裝(zhuang)。環(huan)氧(yang)樹脂絕緣筒外殼(ke),具有足夠的(de)電氣、機械強度,必要的(de)散熱(re)能力以及油(you)熱(re)脹冷(leng)縮的(de)裕度。外殼(ke)上下蓋(gai)板,顏色為橘紅色。
十、電容分壓器技術參數(shu):
額定電壓:200kV;
工作頻(pin)率(lv):30~300Hz;
分壓比(bi):2000:1;
分壓比(bi)誤差(cha):1%;
電容分壓器接線端子如圖所(suo)示:
高(gao)壓端—與電抗器(qi)高(gao)壓側及被試品高(gao)壓側相連(lian)。
測量(liang)(liang)插座—采用專配的測量(liang)(liang)電纜與控制箱背板測量(liang)(liang)輸入端(duan)連接。
接(jie)地(di)端—采用專(zhuan)配(pei)接(jie)地(di)線按接(jie)線圖(tu)指示接(jie)地(di)。
4.性能及特(te)點:
a.額定電壓下(xia)可連續運行2小時。
b.在30~300Hz范(fan)圍內,其精度(du)和穩定度(du)保(bao)持不變。
c.在(zai)20℃溫度(du)下電容(rong)分(fen)壓器(qi)介質損(sun)耗(hao)值(zhi)≤0.0025
d.電容分(fen)壓器配有支撐底架,具有足夠的穩定性。
e.電(dian)壓測(ce)量(liang)(liang)通(tong)過專用測(ce)試引(yin)線引(yin)至(zhi)調頻電(dian)源進行測(ce)量(liang)(liang)。
試(shi)驗接(jie)線(xian)圖:
110kv主變、GIS試驗接線(xian)
35kv電纜(lan)試驗接(jie)線(xian)圖
10kv電纜試驗(yan)接線(xian)圖(tu)
十二、設備保存和維護
1、存(cun)放于干(gan)燥、清潔場地,防(fang)止(zhi)雨水、灰(hui)塵進入(ru)部件內部;
2、如若(ruo)長期不(bu)使用,正(zheng)常(chang)天(tian)氣(qi)至少2個(ge)月應(ying)通(tong)(tong)電一(yi)次(ci)時(shi)(shi)間(jian)不(bu)少于半小(xiao)時(shi)(shi),雨(yu)季及潮濕期應(ying)每隔一(yi)個(ge)月通(tong)(tong)電一(yi)次(ci),通(tong)(tong)電時(shi)(shi)間(jian)半小(xiao)時(shi)(shi),以驅(qu)除設備內(nei)的潮氣(qi)防止電子元器件的銹(xiu)蝕,影響(xiang)正(zheng)常(chang)使用。
3、定期(qi)檢查裝置各部(bu)件,確保各接(jie)頭緊固(gu)無(wu)松動;
4、更換(huan)打(da)印(yin)(yin)紙(zhi),機(ji)器(qi)采用熱敏打(da)印(yin)(yin)紙(zhi)并且是前換(huan)紙(zhi)式當需要(yao)(yao)換(huan)紙(zhi)時只(zhi)要(yao)(yao)按POST鍵鈕打(da)印(yin)(yin)紙(zhi)艙(cang)門就會(hui)打(da)開可以將新打(da)印(yin)(yin)紙(zhi)裝(zhuang)入;
十(shi)三、常見故障排(pai)除
故障現象
|
發 生 原 因(yin)
|
排 除 方 法
|
找不到(dao)諧振(zhen)點
|
接線有誤。
輸出開關未開,;
3、做GIS時PT二(er)次回路未打(da)開;
4、試品(pin)Q值(zhi)太低;
5、起始激勵功率太低;
6、試驗回(hui)路有短(duan)路現象;
7、找(zhao)頻(pin)范(fan)圍不對。
|
退出試驗狀態,合(he)上輸出開關,檢查接線;打開PT二次回路;
調(diao)高(gao)起始功率(∠30%);
用兆(zhao)歐表測量(liang)試品絕緣(yuan)
重(zhong)新(xin)設置找頻范圍
|
諧振后,電壓升(sheng)不(bu)上去
|
1、試(shi)品Q值太低;
2、激(ji)勵(li)電壓(ya)不夠;
3、電抗器(qi)底部有鐵磁物體;
4、3次諧波諧振。
|
檢查試品(pin);
改變激勵變壓器(qi)繞組接法,提高(gao)勵磁電壓
絕緣筒架高電抗器或離開鐵磁物體。
|
主機自動(dong)復位(wei)
|
供電(dian)(dian)電(dian)(dian)源容量不夠;
電源(yuan)引線過長或線徑過小;
接(jie)頭處接(jie)觸**;
供電(dian)電(dian)壓波動;
按鍵死接觸。
|
增加供電電源(yuan)容(rong)量;
換較粗(cu)導(dao)線,減小導(dao)線長度;
檢查接頭;
減小供(gong)電(dian)電(dian)壓波(bo)動。
|
開機后線(xian)路跳(tiao)閘(zha)
|
線路漏電保(bao)護器較為敏感;
空氣開(kai)關(guan)容(rong)量(liang)不夠(gou)。
|
跨過漏電(dian)保(bao)護器或空氣開關的接線;
改換較大容量的(de)空氣開關。
|
電壓跌落
|
試品放電或擊穿(chuan)
|
檢查(cha)試(shi)品
|
輸出短路
|
電流超過本機限流值。
|
檢查接線和試品。
|
試品電壓不準
|
分壓比設置錯誤或(huo)分壓器信號傳輸(shu)有問題。
|
重(zhong)設分壓(ya)(ya)比或檢查分壓(ya)(ya)器接線。
|
電壓閃變
|
試驗電壓劇烈波動,變化率(lv)超過本(ben)機限(xian)定值。
|
檢查供電電源電壓(ya)穩定性(xing)或試品參數的(de)變化(hua)。
|
回路無電流
|
|
檢查(cha)接線(xian)和試(shi)品。
|
未接(jie)好地線
|
|
檢查接(jie)地線和地樁,按(an)說(shuo)明書要求連(lian)接(jie)。
|
試品過電(dian)壓
|
手動(dong)升壓太快或失控。
|
改(gai)變調壓步(bu)距或(huo)改(gai)用自動升壓 。
|
系(xi)統不諧振
|
接線有誤或試(shi)品Q值太低。
|
檢查(cha)接(jie)線和(he)試品
|
十四、常用設備資料參考
交(jiao)聯聚(ju)乙(yi)烯(xi)電(dian)纜單(dan)位長度(du)電(dian)容量
電纜導(dao)體截面積(ji)(平方毫米)
|
電 容 (μ/km)
|
YJV、YJLV
|
YJV、YJLV
|
YJV、YJV、YJLV
|
YJV、YJLV
|
YJV、YJLV
|
6/6kV、6/10kV
|
8.7/10kV、8.7/15kV
|
12/35kV
|
21/35kV
|
26/35kV
|
1×35
|
0.212
|
0.173
|
0.152
|
|
|
1×50
|
0.237
|
0.192
|
0.166
|
0.118
|
0.114
|
1×70
|
0.270
|
0.217
|
0.187
|
0.131
|
0.125
|
1×95
|
0.301
|
0.240
|
0.206
|
0.143
|
0.135
|
1×120
|
0.327
|
0.261
|
0.223
|
0.153
|
0.143
|
1×150
|
0.358
|
0.284
|
0.241
|
0.164
|
0.153
|
1×185
|
0.388
|
0.307
|
0.267
|
0.180
|
0.163
|
1×240
|
0.430
|
0.339
|
0.291
|
0.194
|
0.176
|
1×300
|
0.472
|
0.370
|
0.319
|
0.211
|
0.190
|
1×400
|
0.531
|
0.418
|
0.352
|
0.231
|
0.209
|
1×500
|
0.603
|
0.438
|
0.388
|
0.254
|
0.232
|
1×600
|
0.667
|
0.470
|
0.416
|
0.287
|
0.256
|
2、交聯聚(ju)乙烯電纜單位長(chang)度(du)電容量
電(dian)纜(lan)導體截(jie)面積(平方(fang)毫米)
|
電(dian) 容(rong) (μF/km)
|
YJV、YJLV
|
YJV、YJLV
|
YJV、YJV、YJLV
|
YJV、YJLV
|
YJV、YJLV
|
6/6kV、6/10kV
|
8.7/10kV、8.7/15kV
|
12/35kV
|
21/35kV
|
26/35kV
|
3×35
|
0.212
|
0.173
|
0.152
|
|
|
3×50
|
0.237
|
0.192
|
0.166
|
0.118
|
0.114
|
3×70
|
0.270
|
0.217
|
0.187
|
0.131
|
0.125
|
3×95
|
0.301
|
0.240
|
0.206
|
0.143
|
0.135
|
3×120
|
0.327
|
0.261
|
0.223
|
0.153
|
0.143
|
3×150
|
0.358
|
0.284
|
0.241
|
0.164
|
0.153
|
3×185
|
0.388
|
0.307
|
0.267
|
0.180
|
0.163
|
3×240
|
0.430
|
0.339
|
0.291
|
0.194
|
0.176
|
3×300
|
0.472
|
0.370
|
0.319
|
0.211
|
0.190
|
3×400
|
0.531
|
0.418
|
0.352
|
0.231
|
0.209
|
3×500
|
0.603
|
0.438
|
0.388
|
0.254
|
0.232
|
3×600
|
0.667
|
0.470
|
0.416
|
0.287
|
0.256
|
3、交聯(lian)聚(ju)乙烯電(dian)纜單位長(chang)度電(dian)容(rong)量
電纜導體(ti)截面積(平方毫米(mi))
|
電 容 (μF/km)
|
YJV、YJLV
|
YJV、YJLV
|
64/110kV
|
128/220kV
|
3×240
|
0.129
|
|
3×300
|
0.139
|
|
3×400
|
0.156
|
0.118
|
3×500
|
0.169
|
0.124
|
3×630
|
0.188
|
0.138
|
3×800
|
0.214
|
0.155
|
3×1000
|
0.231
|
0.172
|
3×1200
|
0.242
|
0.179
|
3×1400
|
0.259
|
0.190
|
3×1600
|
0.273
|
0.198
|
3×1800
|
0.284
|
0.297
|
3×2000
|
0.296
|
0.215
|
3×2200
|
|
0.221
|
3×2500
|
|
0.232
|
4、60kV級全絕緣變壓器的(de)電容(pF)
類 型
|
變 壓 器 容 量 kVA
|
630
|
2000
|
3150
|
6300
|
8000
|
1600
|
高壓-地
|
2700
|
4100
|
4600
|
5900
|
7000
|
8200
|
低壓-地(di)
|
4200
|
6600
|
7900
|
10000
|
11000
|
15300
|
對(dui)于表(biao)中(zhong)沒有的產(chan)品,可根(gen)據(ju)表(biao)中(zhong)的上(shang)、下(xia)容(rong)(rong)(rong)量(liang)近似地(di)估算。同容(rong)(rong)(rong)量(liang)的雙繞(rao)組變壓器(qi),其繞(rao)組電(dian)容(rong)(rong)(rong)要比三繞(rao)組產(chan)品小(xiao)。
5、110kV級中性點分級絕緣變壓器的電(dian)容(pF)
類 型
|
變 壓 器(qi) 容 量kVA
|
50000
|
31500
|
20000
|
10000
|
5600
|
高(gao)壓(ya)-中壓(ya)、低壓(ya)、地
|
14200
|
11400
|
8700
|
6150
|
4200
|
中壓-高(gao)壓、低壓、地(di)
|
24800
|
11800
|
13200
|
9600
|
-
|
低(di)壓-高(gao)壓、中壓、地
|
19300
|
19300
|
12000
|
9400
|
6800
|
6、220kV級中性點非全級絕緣(yuan)部(bu)分變壓器的電容(pF)
試 品 型 號
|
SEPSL-63000
|
SSPSL-120000
|
SSPSL-240000
|
類 型
|
高(gao)壓-中壓、低壓及地
|
12100
|
13500
|
17050
|
中壓-高壓、低壓及(ji)地
|
18500
|
19700
|
23260
|
低壓-高壓、中壓及地
|
18200
|
23600
|
29940
|
試 品 型 號
|
SFPL-240000
|
SFP-360000
|
SFPSZL-120000
|
類 型(xing)
|
高(gao)壓(ya)(ya)-中壓(ya)(ya)、低(di)壓(ya)(ya)及地
|
32230
|
33910
|
38020
|
中壓-高壓、低壓及地
|
-
|
-
|
23260
|
低壓-高(gao)壓、中壓及地
|
22470
|
23790
|
22160
|
7、油(you)浸(jin)式電力變壓器交流試驗(yan)電壓
額定電壓
(k V)
|
*高(gao)工作
電壓(ya)(k V)
|
線端交流(liu)試(shi)驗電壓值(kV)
|
中性點交流試驗電(dian)壓值(kV)
|
全部更換繞(rao)組
|
部分更換繞組或交接
|
全部更(geng)換繞組
|
部分更換繞(rao)組(zu)或交接
|
<1
|
≤1
|
3
|
2.5
|
3
|
2.5
|
3
|
3.5
|
18
|
15
|
18
|
15
|
6
|
6.9
|
25
|
21
|
25
|
21
|
10
|
11.5
|
35
|
30
|
35
|
30
|
15
|
17.5
|
45
|
38
|
45
|
38
|
20
|
23.0
|
55
|
47
|
55
|
47
|
35
|
40.5
|
85
|
72
|
85
|
72
|
110
|
126.0
|
200
|
170(195)
|
95
|
80
|
220
|
252.0
|
360
|
306
|
85
|
72
|
395
|
336
|
(200)
|
(170)
|
500
|
550.0
|
630
|
536
|
85
|
72
|
680
|
578
|
140
|
120
|
8、部分型號發電機定子繞組的單相對地(di)電容量(liang)
類(lei)別
|
發 電 機
|
型號(hao)
|
生(sheng)產廠家
|
額定容量(MW)
|
額定電壓(kV)
|
相電容(mF)
|
火
力
發
電
機(ji)
|
QFS-125-2
|
上海電機廠
|
125
|
13.8
|
0.08-0.12
|
QFSN-200-2
|
哈(ha)爾(er)濱(bin)電機(ji)廠
|
200
|
15.75
|
0.19-0.21
|
QFQS-200-2
|
東方電機廠
|
200
|
15.75
|
0.1928-0.21
|
QFQS-200-2
|
北京重型電機廠
|
200
|
15.75
|
0.18-0.19
|
QFS-300-2
|
上海電機廠
|
300
|
18.0
|
0.16-0.20
|
QFSN-300-2
|
上海(hai)電機(ji)廠
|
300
|
18.0
|
0.18-0.20
|
ATB-2
|
美國GE公司(si)
|
352
|
23.0
|
0.268(設計值)
|
TBB-320-2
|
(前蘇聯)
|
320
|
20.0
|
0.31
|
2-105×234
|
美國西屋公司(si)
|
600
|
20.0
|
0.2(工廠試驗(yan)值)
|
50WT23E-138
|
ABB
|
600
|
22.0
|
0.253(設計值)
|
水 發
力 電(dian)
機(ji)
|
|
|
72.5 - 85
|
10.5
|
0.694
|
|
|
300
|
15.75
|
1.7-2.5
|
|
|
400
|
18.0
|
2-2.5
|
9、同步發電(dian)機定子繞(rao)組交(jiao)流試驗電(dian)壓
1
|
全部更(geng)換定(ding)子繞組(zu)并修(xiu)好后的試驗電壓
|
容量kW或kVA
|
小(xiao)于10000
|
10000及以(yi)上
|
額(e)定電壓Un (V)
|
36以上
|
6000以下
|
6000~18000
|
18000以上
|
試驗(yan)電壓V
|
2Un+1000但*低為(wei)1500
|
2.5Un
|
2Un
+3000
|
按專門(men)協議(yi)
|
2
|
大(da)修前或局部更換(huan)定子繞組并修好后的(de)試驗電壓(ya)
|
運(yun)行20年及以下者
|
1.5 Un
|
運行20年以(yi)上與架(jia)空線(xian)路直接連接者
|
1.5 Un
|
運行20年(nian)以上不與(yu)架空線路直接連(lian)接者
|
(1.3~1.5)Un
|
十五、設備成套性:
變頻電源(yuan) 1臺
勵(li)磁變壓器(qi) 1臺
電(dian)抗(kang)器(qi) 4臺
電容分壓器 1臺
附(fu)件(jian)及測試(shi)線(xian) 1套
支架 15KV 1只
均(jun)壓罩 200KV 2只
絕緣底板 2塊
一、產品概述
YDQC系列(lie)輕型交直流(liu)(liu)高壓(ya)(ya)試驗(yan)變壓(ya)(ya)器是在同類產(chan)品YDJ(G)型高壓(ya)(ya)試驗(yan)變壓(ya)(ya)器的基礎上,按試驗(yan)變壓(ya)(ya)器國家標準ZBK41006—89要(yao)求,經改(gai)進(jin)(jin)后生產(chan)的一種新型產(chan)品,本(ben)系列(lie)產(chan)品具有體積小、重量輕、結構緊湊、功能齊全、使用方便(bian)等特點。實用于電(dian)力、工(gong)礦、科研等部門,對各(ge)種高壓(ya)(ya)電(dian)氣(qi)設備、電(dian)氣(qi)元件、絕(jue)緣材料進(jin)(jin)行工(gong)頻(pin)耐壓(ya)(ya)試驗(yan)和直流(liu)(liu)泄漏試驗(yan),是高壓(ya)(ya)試驗(yan)中必不可少的儀器。
二(er)、產品結構
YDQC系列輕(qing)型高(gao)壓(ya)試驗變壓(ya)器鐵芯為單框式。線圈采用同(tong)芯圓筒多層塔式結構(gou),初(chu)級低壓(ya)繞(rao)組繞(rao)在(zai)(zai)鐵芯上,次級高(gao)壓(ya)繞(rao)組繞(rao)在(zai)(zai)低壓(ya)繞(rao)組外(wai)(wai)(wai)側,這(zhe)種同(tong)軸布(bu)置減少了繞(rao)組間(jian)的(de)藕合損耗。高(gao)壓(ya)硅堆用特殊(shu)工(gong)藝封裝(zhuang)在(zai)(zai)套管內(nei),產品(pin)的(de)外(wai)(wai)(wai)殼制成與器芯配合較(jiao)佳的(de)八角形結構(gou),整體外(wai)(wai)(wai)型美觀大方。其內(nei)外(wai)(wai)(wai)部結構(gou)見(jian)圖1。
1-均壓(ya)(ya)(ya)球(qiu);2-硅堆(dui)短路桿;3-高壓(ya)(ya)(ya)套(tao)管(guan);4-油(you)閥;5-殼體(ti);6、7-調整電(dian)壓(ya)(ya)(ya)輸入a、x端子(zi)(zi);8、9-儀表(biao)測量E、F端子(zi)(zi);10-高壓(ya)(ya)(ya)尾(wei)X端子(zi)(zi);11-變壓(ya)(ya)(ya)器(qi)外殼接地端;12-高壓(ya)(ya)(ya)輸出(chu)A端子(zi)(zi);13-高壓(ya)(ya)(ya)整流硅堆(dui);14-內部(bu)均壓(ya)(ya)(ya)環(huan);15-變壓(ya)(ya)(ya)器(qi)鐵(tie)芯;16-初級(ji)低壓(ya)(ya)(ya)繞組(zu);17-測量儀表(biao)繞組(zu);18-二次級(ji)高壓(ya)(ya)(ya)繞組(zu);19-變壓(ya)(ya)(ya)器(qi)油(you)。
三、工作原理
YDQC系列(lie)輕型高(gao)壓(ya)(ya)(ya)試(shi)驗(yan)變壓(ya)(ya)(ya)器(qi)為(wei)單相變壓(ya)(ya)(ya)器(qi),聯結組(zu)標(biao)號II。單臺(tai)(tai)高(gao)壓(ya)(ya)(ya)試(shi)驗(yan)變壓(ya)(ya)(ya)器(qi)的工(gong)作(zuo)過程,用交流(liu)220V(10KVA以(yi)上為(wei)380V)電(dian)壓(ya)(ya)(ya)接入電(dian)源控制(zhi)箱(臺(tai)(tai)),經(jing)電(dian)源控制(zhi)箱(臺(tai)(tai))內(nei)自藕調(diao)壓(ya)(ya)(ya)器(qi)(50KVA以(yi)上調(diao)壓(ya)(ya)(ya)器(qi)外附)調(diao)節0~200V(10KVA以(yi)上0~400V)電(dian)壓(ya)(ya)(ya)至試(shi)驗(yan)變壓(ya)(ya)(ya)器(qi)的初級繞組(zu),根據電(dian)磁感應原理,在試(shi)驗(yan)變壓(ya)(ya)(ya)器(qi)高(gao)壓(ya)(ya)(ya)繞組(zu)可獲得試(shi)驗(yan)所需的高(gao)電(dian)壓(ya)(ya)(ya)。其(qi)工(gong)作(zuo)原理圖(tu)(tu)見圖(tu)(tu)2所示。
1、單臺YDQC高(gao)壓(ya)試驗變(bian)壓(ya)器工(gong)作原(yuan)理示意圖
在試驗變壓器(qi)中:a、x為低壓輸(shu)入端(duan)(duan);A、X 為高壓輸(shu)出端(duan)(duan);E、F為儀表測(ce)量(liang)端(duan)(duan)。
2、單臺交直流兩用型高壓試驗變壓器工作原理見圖3。圖中所示:高壓套管內裝有高壓硅堆,串接在高壓回路中作高壓整流,以獲得直流高電壓。當用一短路桿將高壓硅堆短接時,可獲得交流高電壓,其狀態為交流輸出;反之在抽出短路桿時,其狀態為直流輸出。
3、三臺高壓試驗變壓器串激獲得更高電壓原理見圖4,串激高壓試驗變壓器有很大的優越性,因為整個試驗裝置由多個單臺串激式試驗變壓器組成,單臺試驗變壓器有著體積小、重量輕、便于運輸的特點,它既可以串接成高出幾倍的單臺試驗變壓器輸出電壓組合使用,又可以分開單獨使用。整套試驗裝置投資小、經濟實惠。圖3所示:在三臺串激式試驗變壓器串激使用中,單臺試驗變壓器B1、B2、B3的輸出電壓都是U,**、二級的試驗變壓器內部都有一個激磁繞組,分別為A1、C1 和A2、C2。當控制電壓加在第**試驗變壓器B1的初級繞組a1、x1上,激磁繞組A1、C1給予試驗變壓器B2初級繞組供電,**級試驗變壓器B2的激磁繞組A2、C2給試驗變壓器B3的初級繞組供電。由于第**試驗變壓器B1的高壓尾及殼體接地,**、三級的試驗變壓器B2和B3對地有絕緣支架的隔離,這樣試驗變壓器B1、B2、B3對地輸出電壓分別為1U、2U、3U。
B1、B2、B3- 串激式高(gao)壓變(bian)壓器(qi);1U、2U、3U-各級(ji)對地(di)電壓;
PV- 高壓示值表(KV); ZJ1、ZJ2-絕緣支架。
四、使(shi)用方法及(ji)注意(yi)事(shi)項
1、YDQC高(gao)(gao)(gao)壓(ya)(ya)(ya)試(shi)驗(yan)(yan)變(bian)壓(ya)(ya)(ya)器(qi)做工(gong)頻耐(nai)壓(ya)(ya)(ya)試(shi)驗(yan)(yan)使用接(jie)線方法(fa)見圖(tu)5。做工(gong)頻耐(nai)壓(ya)(ya)(ya)試(shi)驗(yan)(yan)前,先根(gen)據試(shi)驗(yan)(yan)變(bian)壓(ya)(ya)(ya)器(qi)的(de)(de)額定容量(liang)選擇好限流電(dian)阻,(水電(dian)阻)的(de)(de)阻值,再根(gen)據被(bei)試(shi)品需加(jia)的(de)(de)高(gao)(gao)(gao)壓(ya)(ya)(ya)電(dian)壓(ya)(ya)(ya)值調整好放電(dian)球隙的(de)(de)球間距,為了提高(gao)(gao)(gao)對被(bei)試(shi)品施(shi)加(jia)電(dian)壓(ya)(ya)(ya)的(de)(de)測量(liang)精(jing)度(du),應在高(gao)(gao)(gao)壓(ya)(ya)(ya)側接(jie)入(ru)FRC阻容分壓(ya)(ya)(ya)器(qi)來測量(liang)電(dian)壓(ya)(ya)(ya)。
R1、R2- 限流(liu)電阻; Qx- 放電球隙; Zx- 被試品;
FRC- 阻容分壓器; V- 分壓器高壓表。
按照圖4、結合圖2所進行的工頻耐壓試驗接好工作線路,試驗變壓器的高壓繞阻的X端(高壓尾)、儀表測量繞組的F端、試驗變壓器的外殼以及電源控制箱(臺)的外殼必須可靠接地。
用三臺試驗變壓器串激做工頻耐壓試驗時、**、三級試驗變壓器的初級繞組X端,儀表測量繞組的F端,以及高壓繞組的X端(高壓尾)均接本級試驗變壓器的外殼,**、三級試驗變壓器的主體必須放置在絕緣支架上。除第**以外、**、三級試驗變壓器的主體不要接地線。其接線方式見圖3所示。
接電源前,電源控制箱(臺)的調壓器必須調到零位。接通電源后,綠色指示燈亮,按一下啟動按鈕,紅色指示燈亮,表示試驗變壓器已接通控制電源,開始升壓。
從零位開始按順時針方向勻速旋轉調壓器手輪升壓。(升壓方式有:快速升壓法,即20S逐級升壓法,慢速升壓法,即60S逐級升壓法,極慢速升壓法供選用)電壓從零開始按選定的升壓速度升到您所需額定試驗電壓的75%后,再以每秒2%額定試驗電壓的速度升到您所需試驗電壓,并密切注意測量儀表的指示以及被試品的情況,被試品施加電壓的時間到后。應在數秒內勻速將調壓器返回,高壓降至1/3試驗電壓以下,按一下停止按鈕,高壓、低壓輸出停止,然后切斷電源線,試驗完畢。
工(gong)頻(pin)耐壓試驗操作過程(cheng)注意事項
1、試驗人員應做好責任分工,設定好試驗現場的**距離,仔細檢查好被試品及試驗變壓器的接地情況,并設有專人監護**及觀察被試品狀態工作。
2、被試品主要部位應**干凈,保持**干燥,以免損壞被試品和帶來試驗數值的誤差。
3、對大型設備的試驗,一般都應先進行試驗變壓器的空升試驗,即不接試品時升壓至試驗電壓,以便校對好儀表的指示精度,調整好放電球隙的球間距。
4、做耐壓試驗時升壓速度不能過快,并防止突然加壓,例如調壓器不在零位的突然合閘,也不能突然斷電,一般應在調壓器降至零位時分閘。
5、在升壓或耐壓試驗過程中,如發現下列不正常情況,1 電壓、電流表指針擺動很大,2 被試品發出不正常響聲,3 發現絕緣有燒焦或冒煙現象,應立即降壓,切斷電源,停止試驗并查明原因。
6、使用本產品做高壓試驗時,除熟悉本說明書外,還必須嚴格執行國家有關標準和操作規程。
2、YDQ交直流(liu)(liu)兩用(yong)高(gao)壓(ya)(ya)(ya)試(shi)(shi)(shi)驗(yan)變(bian)壓(ya)(ya)(ya)器做直流(liu)(liu)耐壓(ya)(ya)(ya)和泄漏(lou)試(shi)(shi)(shi)驗(yan)使用(yong)接線方法見圖5。由(you)于是交直流(liu)(liu)兩用(yong)高(gao)壓(ya)(ya)(ya)試(shi)(shi)(shi)驗(yan)變(bian)壓(ya)(ya)(ya)器,應把高(gao)壓(ya)(ya)(ya)硅堆短路桿從套(tao)管中抽(chou)出,使試(shi)(shi)(shi)驗(yan)變(bian)壓(ya)(ya)(ya)器為(wei)直流(liu)(liu)輸(shu)(shu)出狀態。做直流(liu)(liu)泄漏(lou)試(shi)(shi)(shi)驗(yan)前,先(xian)根據泄漏(lou)試(shi)(shi)(shi)驗(yan)中輸(shu)(shu)出端斷路電(dian)流(liu)(liu)不超過高(gao)壓(ya)(ya)(ya)硅堆的(de)*大整(zheng)流(liu)(liu)為(wei)宜,選(xuan)擇好限流(liu)(liu)電(dian)阻(zu)(水電(dian)阻(zu))的(de)阻(zu)值(zhi),再根據被(bei)試(shi)(shi)(shi)品(pin)對(dui)(dui)直流(liu)(liu)高(gao)壓(ya)(ya)(ya)波形的(de)要求(qiu)選(xuan)擇好高(gao)壓(ya)(ya)(ya)濾波電(dian)容(rong)(rong)的(de)電(dian)容(rong)(rong)值(zhi)。為(wei)了(le)提高(gao)對(dui)(dui)被(bei)試(shi)(shi)(shi)品(pin)施加(jia)電(dian)壓(ya)(ya)(ya)的(de)測(ce)量(liang)精度,應在高(gao)壓(ya)(ya)(ya)側(ce)接入FRC阻(zu)容(rong)(rong)分壓(ya)(ya)(ya)器來測(ce)量(liang)電(dian)壓(ya)(ya)(ya)。
R- 限(xian)流電阻; C- 高壓濾(lv)波電容; Zx- 被試品; G- 硅堆短路桿;
FRC- 阻容分壓器;V- 分壓器高壓表;uA- 微安表;D- 高壓整流硅堆。
按照圖5、結合圖3所進行的直流泄漏試驗接好工作線路。試驗變壓器的高壓繞組的X端(高壓尾)、儀表測量繞組的F 端、試驗變壓器的外殼以及電源控制箱(臺)的外殼必須可靠接地。
接電(dian)(dian)源前、電(dian)(dian)源控制箱(臺(tai))的調(diao)壓器(qi)必須調(diao)到零(ling)位。接通(tong)電(dian)(dian)源后,綠色指(zhi)示燈(deng)(deng)亮,按一下啟動按鈕,紅色指(zhi)示燈(deng)(deng)亮,表(biao)示試驗變壓器(qi)已接通(tong)控制電(dian)(dian)源,開(kai)始升壓。
從零位(wei)(wei)開始按順時(shi)針方(fang)(fang)向(xiang)勻速(su)(su)(su)旋轉調(diao)壓(ya)(ya)(ya)器手輪(lun)升壓(ya)(ya)(ya)。(升壓(ya)(ya)(ya)方(fang)(fang)式有:快速(su)(su)(su)升壓(ya)(ya)(ya)法(fa)即20S逐級升壓(ya)(ya)(ya)法(fa);慢(man)速(su)(su)(su)升壓(ya)(ya)(ya)法(fa),即60S逐級升壓(ya)(ya)(ya)法(fa);級慢(man)速(su)(su)(su)升壓(ya)(ya)(ya)法(fa)供選用)電(dian)(dian)壓(ya)(ya)(ya)從零開始按選定(ding)的(de)升壓(ya)(ya)(ya)速(su)(su)(su)度升到您所(suo)需(xu)額(e)定(ding)試(shi)驗(yan)電(dian)(dian)壓(ya)(ya)(ya)或額(e)定(ding)直(zhi)(zhi)流(liu)(liu)(liu)電(dian)(dian)流(liu)(liu)(liu)下(xia)的(de)參考電(dian)(dian)壓(ya)(ya)(ya)。試(shi)驗(yan)中(zhong)應嚴密注(zhu)意直(zhi)(zhi)流(liu)(liu)(liu)高壓(ya)(ya)(ya)表(biao)、泄(xie)漏電(dian)(dian)流(liu)(liu)(liu)表(biao)指示(shi)以及被(bei)試(shi)品(pin)的(de)情況。試(shi)驗(yan)完畢后(hou),應訊速(su)(su)(su)均(jun)勻將高壓(ya)(ya)(ya)降(jiang)至零位(wei)(wei),按一下(xia)停止(zhi)按鈕(niu),高壓(ya)(ya)(ya)、低(di)壓(ya)(ya)(ya)輸出停止(zhi),然后(hou)切斷電(dian)(dian)源。此時(shi)應用直(zhi)(zhi)流(liu)(liu)(liu)高壓(ya)(ya)(ya)放**給被(bei)試(shi)品(pin)及試(shi)驗(yan)裝置本(ben)身充分放電(dian)(dian)。
直(zhi)流(liu)泄漏試驗操作過程注意事(shi)項
(1)試驗人員應做好責任分工,設定好試驗現場的**距離,仔細檢查好被試品及試驗變壓器的接地情況,并設有專人監護**及觀察被試品狀態工作。
(2)被試品做試驗前,應拆除所有對外連線,并充分放電,主要部位應**干凈,保持**干燥,以免損壞被試品及帶來試驗數值的誤差。
(3)對于大容量試品(電容器、超長電纜等)試驗時應緩慢升壓,防止被試品的充電電流過大而燒壞微安表,必要時應分級加壓分別讀取各電壓下微安表的穩定讀數。
(4)試驗過程中,應嚴密監視被試品、微安表及試驗裝置等,一旦發生閃爍、擊穿等現象應立即降壓,切斷電源,并查明原因。
五、配套(tao)選購產品
下列產品僅供選擇,購買時需另行計價。
1.KZX系列電源控制箱 容量:1KVA-5KVA、輸入電壓:220V
2.KZT系列電源控制臺 容量:10KVA~300KVA輸入電壓:220V或380V
3.數字微安表:SWB-II
4.高壓濾波電容: 0.01MF、40 ~ 100KV
5.高壓直流放**: FBR— 70、140、210KV
6.放電球隙: Q—50、100、150、200、250、500
7.標準試油杯: 400ml
8.折疊式手推車: 150、300型
9.絕緣支架: 50、100、200、300、400KV
10.阻容分壓器: FRC —50、100、150、200KV
11.高壓硅堆: 2DL—150、300、450KV
12.水 電 阻: 50、100
六、主要試驗設備的選(xuan)擇
1、試驗變壓器
其高壓側額定電壓應不小于被試品的*高試驗電壓,額定電流不小于被試品的*大電容電流。被試品的電容電流和試驗變壓器所需容量計算式為:
被(bei)試(shi)品(pin)(pin)電(dian)(dian)容(rong)量(liang)Cx可由交流電(dian)(dian)橋測(ce)出。常(chang)用的被(bei)試(shi)品(pin)(pin)電(dian)(dian)容(rong)量(liang)按(an)表(biao)1選(xuan)取(qu)。
幾種常用被試品的電容量(liang)(pF) 表1
2、調壓設(she)備
(1)自藕調壓器。其調壓范圍廣、功率損耗小、波形畸變小、選擇這種調壓方式為*好。自藕調壓器的容量按0.75 ~ 1倍的試驗變壓器的容量選擇,適用于容量為100KVA以下的試驗變壓器的調壓。
(2)感應調壓器。其調壓范圍大,波形畸形小、但結構復雜、價格較貴,當試驗變壓器的容量較大時(如100KVA以上)使用。
3、限流電阻
限流電阻的作用是,當被試品擊穿時,限制斷路電流,從而保護試驗變壓器,防止故障的擴大。其數值以*高試驗電壓為準,按0.5 ~ 1 Ω / V(有效值)選擇,限流電阻可用水電阻。注意水不能充滿玻璃管,應留有余地,以防爆裂。
4、放電球隙
放電球隙的布置方式有垂直和水平兩種,球隙間距S和球的直徑D的關系應保護在0.05D ≤S ≤0.5D范圍內,球隙上的水電阻阻值一般按0.1 ~ 1Ω/V選取,設置放電球隙的目的是為了對重要的被試品起保護作用,可以將由于誤操作或被試品擊穿引起的過電壓限制在允許的范圍內。
七、試驗(yan)變(bian)壓器技(ji)術指示
型號
|
容量
|
高壓電壓
|
高壓電流(liu)
|
低壓輸入(ru)
|
變比
|
溫升℃
|
(KVA)
|
(KV)
|
(mA)
|
電壓(V)
|
電流(A)
|
高/儀
|
30分鐘(zhong)
|
YDQC-1.5/50
|
1.5
|
50
|
30
|
200
|
7.5
|
500
|
10
|
YDQC-3/50
|
3
|
50
|
60
|
200
|
15
|
500
|
10
|
YDQC-5/50
|
5
|
50
|
100
|
200
|
25
|
500
|
10
|
YDQC-10/50
|
10
|
50
|
200
|
200
|
50
|
500
|
10
|
YDQC-15/50
|
15
|
50
|
300
|
200
|
75
|
500
|
10
|
YDQC-20/50
|
20
|
50
|
400
|
380
|
53
|
500
|
10
|
YDQC-30/50
|
30
|
50
|
600
|
380
|
79
|
500
|
10
|
YDQC-50/50
|
50
|
50
|
1000
|
380
|
12
|
500
|
10
|
YDQC-5/100
|
5
|
100
|
50
|
200
|
25
|
1000
|
10
|
YDQC-10/100
|
10
|
100
|
100
|
200
|
50
|
1000
|
10
|
YDQC-20/100
|
20
|
100
|
200
|
400
|
50
|
1000
|
10
|
YDQC-30/100
|
30
|
100
|
300
|
400
|
75
|
1000
|
10
|
YDQC-50/100
|
50
|
100
|
500
|
400
|
125
|
1000
|
10
|
YDQC-20/150
|
20
|
150
|
133
|
400
|
50
|
1500
|
10
|
YDQC-30/150
|
30
|
150
|
200
|
400
|
75
|
1500
|
10
|
YDQC-50/150
|
50
|
150
|
333
|
400
|
125
|
1500
|
10
|
YDQC-100/150
|
100
|
150
|
667
|
400
|
250
|
1500
|
10
|
YDQC-50/200
|
50
|
200
|
250
|
400
|
125
|
2000
|
10
|
YDQC-100/200
|
100
|
200
|
500
|
400
|
250
|
2000
|
10
|
YDQC-150/200
|
150
|
200
|
750
|
400
|
375
|
2000
|
10
|
YDQC-200/200
|
200
|
200
|
1000
|
400
|
500
|
2000
|
10
|
YDQC-300/200
|
300
|
200
|
1500
|
400
|
600
|
2000
|
10
|
YDQC-50/300
|
50
|
300
|
170
|
400
|
125
|
3000
|
10
|
YDQC-100/300
|
100
|
300
|
333
|
400
|
250
|
3000
|
10
|
YDQC-150/300
|
150
|
300
|
500
|
400
|
375
|
3000
|
10
|
YDQC-200/300
|
200
|
300
|
667
|
400
|
500
|
3000
|
10
|
YDQC-300/300
|
300
|
300
|
3000
|
500
|
600
|
3000
|
10
|
1、使用環境條件
環境溫度不高于+40℃、不低于—20℃;空氣相對濕度不大于90%;海拔高度不超過2000米;
2、工作電壓
電源控制箱(臺)輸入電壓為工頻220V或380V、相對誤差不超過±10%;(具體使用電壓根據用戶所定試驗變壓器規格選取)
八、隨貨文件
YDQC 系列試驗變壓器產品說明書 1份
產品出廠試驗報告 1份
產品合格證 1份
裝箱單 1份
一(yi)、概述
YDQ系(xi)(xi)列高(gao)(gao)壓(ya)(ya)試(shi)驗變(bian)壓(ya)(ya)器是(shi)根據《試(shi)驗變(bian)壓(ya)(ya)器》標(biao)(biao)準(zhun),在(zai)油浸(jin)(jin)式試(shi)驗變(bian)壓(ya)(ya)器的(de)(de)基(ji)礎上而設(she)計生產的(de)(de)。SF6氣(qi)(qi)體(ti)(ti)具有良好的(de)(de)電(dian)氣(qi)(qi)絕(jue)緣(yuan)(yuan)性能及(ji)優異的(de)(de)滅弧性能,其耐(nai)壓(ya)(ya)強(qiang)度(du)為同一壓(ya)(ya)力(li)下氮氣(qi)(qi)的(de)(de)2.5倍,擊穿電(dian)壓(ya)(ya)的(de)(de)空氣(qi)(qi)的(de)(de)2.5倍。在(zai)0.25MPa下與油的(de)(de)擊穿電(dian)壓(ya)(ya)相等,在(zai)0.45MPa壓(ya)(ya)力(li)下是(shi)油的(de)(de)擊穿電(dian)壓(ya)(ya)的(de)(de)2倍,是(shi)一種優于油的(de)(de)新一代超高(gao)(gao)壓(ya)(ya)絕(jue)緣(yuan)(yuan)介質材料。該產品(pin)技術要(yao)求(qiu)完全符合《ZBK-41006-89》標(biao)(biao)準(zhun),它是(shi)油浸(jin)(jin)式輕(qing)型試(shi)驗變(bian)壓(ya)(ya)器的(de)(de)換代產品(pin)。該產品(pin)具有體(ti)(ti)積小、重量輕(qing)、不受氣(qi)(qi)候變(bian)化影(ying)響、電(dian)暈(yun)小、現場(chang)搬運無需(xu)靜(jing)止可(ke)使用,使用壽(shou)命長、免維修等特點。適用于電(dian)力(li)系(xi)(xi)統、工(gong)礦企(qi)業、科研部(bu)門等對(dui)各種高(gao)(gao)壓(ya)(ya)電(dian)氣(qi)(qi)設(she)備、電(dian)氣(qi)(qi)元件、絕(jue)緣(yuan)(yuan)材料進行(xing)工(gong)頻或直流高(gao)(gao)壓(ya)(ya)下的(de)(de)絕(jue)緣(yuan)(yuan)強(qiang)度(du)試(shi)驗。
二、產品結(jie)構
YDQ系列高(gao)壓(ya)試驗變壓(ya)器采(cai)用單框芯式鐵芯結構(gou)(gou),初(chu)級繞(rao)組(zu)繞(rao)在鐵芯上,高(gao)壓(ya)繞(rao)組(zu)在外,這種同軸布置減少了(le)漏磁通,因而(er)增大了(le)繞(rao)組(zu)間的耦合。產品的外殼為(wei)圓柱灌式容器結構(gou)(gou),能耐受0.8MPa以上壓(ya)力(li)。其(qi)結構(gou)(gou)見圖(tu)1:
三、工作(zuo)原理
YDQ系列(lie)高壓(ya)試(shi)驗(yan)(yan)變(bian)(bian)壓(ya)器為單相(xiang)變(bian)(bian)壓(ya)器,聯結組標(biao)號Ⅰ.Ⅰ. 用(yong)工頻220V(10kVA以上為380V)電(dian)源接入 (為本公司生產的試(shi)驗(yan)(yan)變(bian)(bian)壓(ya)器配套專(zhuan)用(yong)設備,詳細(xi)資(zi)料請見其具體使用(yong)說明書(shu))系列(lie)操作箱(xiang)(臺),經(jing)操作箱(xiang)內自(zi)偶調壓(ya)器(50kVA以上調壓(ya)器外附(fu))調節至0~200V(或0~400V)電(dian)壓(ya)輸出至YDQ試(shi)驗(yan)(yan)變(bian)(bian)壓(ya)器的初級(ji)繞組,根據電(dian)磁感(gan)應原理,在試(shi)驗(yan)(yan)變(bian)(bian)壓(ya)器高壓(ya)繞組可(ke)獲得試(shi)驗(yan)(yan)所需的高電(dian)壓(ya)。
單臺(tai)YDQ系列交(jiao)直流高(gao)壓(ya)試驗變壓(ya)器的工作(zuo)原理圖(tu)見(jian)圖(tu)3,圖(tu)中高(gao)壓(ya)套管中裝有高(gao)壓(ya)硅(gui)堆(dui),串接在高(gao)壓(ya)回(hui)路(lu)中作(zuo)半(ban)波整流,以獲(huo)(huo)得直流高(gao)電壓(ya)。當用一短(duan)(duan)路(lu)桿(gan)將(jiang)高(gao)壓(ya)硅(gui)堆(dui)短(duan)(duan)接時,可(ke)獲(huo)(huo)得工頻高(gao)電壓(ya),作(zuo)為(wei)交(jiao)流輸(shu)出狀態;取消短(duan)(duan)路(lu)桿(gan)時,作(zuo)為(wei)直流輸(shu)出狀態。
圖中:D—短路桿 VD—高(gao)壓硅堆
試驗變壓器高壓套(tao)管中的高壓硅堆(dui)未畫出,其原理與上圖相(xiang)同。
三臺試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)串(chuan)(chuan)級(ji)(ji)(ji)(ji)獲得更高(gao)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)的(de)接(jie)線原(yuan)(yuan)理見圖4。串(chuan)(chuan)級(ji)(ji)(ji)(ji)高(gao)壓(ya)(ya)(ya)(ya)(ya)(ya)試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)有(you)很大的(de)優(you)越性,因(yin)為(wei)(wei)整個(ge)試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)裝(zhuang)置由(you)幾臺單(dan)臺試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)組(zu)成,單(dan)臺試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)容(rong)(rong)量(liang)(liang)小、電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)低(di)、重(zhong)量(liang)(liang)輕,便于(yu)運(yun)輸(shu)和安裝(zhuang)。它(ta)既然可串(chuan)(chuan)接(jie)成高(gao)出(chu)幾倍的(de)單(dan)臺試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)輸(shu)出(chu)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)組(zu)合使(shi)用(yong),又可分開成幾套單(dan)臺試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)單(dan)獨使(shi)用(yong)。整套裝(zhuang)置投資小,經濟實惠(hui)。圖5中(zhong),在(zai)第(di)**和**級(ji)(ji)(ji)(ji)的(de)每個(ge)單(dan)元試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)中(zhong)都有(you)一個(ge)勵磁繞(rao)組(zu)A1、C1和A2、C2。在(zai)三臺串(chuan)(chuan)級(ji)(ji)(ji)(ji)試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)基本原(yuan)(yuan)理中(zhong),低(di)壓(ya)(ya)(ya)(ya)(ya)(ya)電(dian)(dian)源(yuan)加在(zai)試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)Ⅰ的(de)初級(ji)(ji)(ji)(ji)繞(rao)組(zu)a1x1上,單(dan)臺試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)Ⅰ、Ⅱ、Ⅲ的(de)輸(shu)出(chu)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)都是(shi)V。勵磁繞(rao)組(zu)A1、C1給**級(ji)(ji)(ji)(ji)試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)Ⅱ的(de)初級(ji)(ji)(ji)(ji)繞(rao)組(zu)供電(dian)(dian);**級(ji)(ji)(ji)(ji)試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)Ⅱ的(de)勵磁繞(rao)組(zu)A2、C2給第(di)三級(ji)(ji)(ji)(ji)試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)Ⅲ的(de)初級(ji)(ji)(ji)(ji)繞(rao)組(zu)供電(dian)(dian)。**級(ji)(ji)(ji)(ji)試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)Ⅱ和第(di)三級(ji)(ji)(ji)(ji)試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)Ⅲ的(de)箱體(ti)分別(bie)處在(zai)對(dui)(dui)地(di)(di)為(wei)(wei)1V和2V的(de)高(gao)電(dian)(dian)位上,所(suo)以(yi)箱體(ti)對(dui)(dui)地(di)(di)是(shi)絕緣(yuan)的(de),試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)Ⅰ的(de)箱體(ti)是(shi)接(jie)地(di)(di)的(de)。這樣第(di)**、**級(ji)(ji)(ji)(ji)、第(di)三級(ji)(ji)(ji)(ji)試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)對(dui)(dui)地(di)(di)的(de)額定輸(shu)出(chu)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)分別(bie)為(wei)(wei)1V、2V、3V;其額定容(rong)(rong)量(liang)(liang)分別(bie)為(wei)(wei)3P、2P、1P。
YDQ系列(lie)高(gao)壓(ya)(ya)試驗變壓(ya)(ya)器做被試品的工頻耐(nai)壓(ya)(ya)試驗使用(yong)接線原(yuan)理圖見圖5。
圖中:R1—限流電阻 FRC—阻容分壓器(qi) RF—球(qiu)(qiu)間隙(xi)保護電阻 G—球(qiu)(qiu)間隙(xi) CX—被試品
注:高壓尾必須(xu)可靠(kao)接(jie)地
工(gong)頻耐壓試驗(yan)中限流電(dian)阻R1應(ying)根據試驗(yan)變(bian)壓器的額(e)定(ding)容(rong)量(liang)來選擇(ze)。如高(gao)壓側額(e)定(ding)輸出(chu)(chu)電(dian)流在(zai)100~300mA時,可(ke)取(qu)0.5~1Ω/V(試驗(yan)電(dian)壓);高(gao)壓側額(e)定(ding)輸出(chu)(chu)電(dian)流為(wei)1A以上時,可(ke)取(qu)1Ω/V(試驗(yan)電(dian)壓)。常用(yong)水電(dian)阻作為(wei)限流電(dian)阻,管(guan)子長度可(ke)按(an)150kV/m考慮(lv),管(guan)子粗細(xi)應(ying)具有足夠(gou)的熱容(rong)量(liang)(水阻液配(pei)制方法:用(yong)蒸餾水加(jia)入(ru)適量(liang)硫酸銅配(pei)制成(cheng)各(ge)種(zhong)不同的阻值)。
球間(jian)隙及保護電(dian)(dian)阻:當電(dian)(dian)壓超過球間(jian)隙整定值時(一(yi)般取試(shi)驗電(dian)(dian)壓的110%~120%),球間(jian)隙放電(dian)(dian),對被試(shi)品起到保護作用。球間(jian)隙保護電(dian)(dian)阻可(ke)按1Ω/V(試(shi)驗電(dian)(dian)壓)選(xuan)取。
在工頻(pin)(pin)耐壓(ya)(ya)(ya)(ya)試(shi)驗(yan)中,低電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)側測量電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(儀表電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya))不是(shi)非常(chang)(chang)準確(que)的(de)(de),其原(yuan)因是(shi)由于(yu)試(shi)驗(yan)變壓(ya)(ya)(ya)(ya)器(qi)存(cun)(cun)在著漏抗(kang),在這個(ge)漏抗(kang)上(shang)(shang)必(bi)然存(cun)(cun)在著壓(ya)(ya)(ya)(ya)降或(huo)(huo)容(rong)升,使試(shi)品(pin)上(shang)(shang)的(de)(de)電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)低于(yu)或(huo)(huo)高于(yu)低壓(ya)(ya)(ya)(ya)側測量電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)表上(shang)(shang)反映出來(lai)(lai)的(de)(de)電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)。工頻(pin)(pin)耐壓(ya)(ya)(ya)(ya)試(shi)驗(yan)時(shi),被試(shi)品(pin)上(shang)(shang)的(de)(de)電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)高于(yu)試(shi)驗(yan)變壓(ya)(ya)(ya)(ya)器(qi)的(de)(de)輸(shu)出電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya),也(ye)就(jiu)是(shi)所(suo)謂容(rong)升現象。感應耐壓(ya)(ya)(ya)(ya)試(shi)驗(yan)時(shi),試(shi)驗(yan)變壓(ya)(ya)(ya)(ya)器(qi)的(de)(de)漏抗(kang)必(bi)然存(cun)(cun)在著壓(ya)(ya)(ya)(ya)降。為了準確(que)測量被試(shi)品(pin)上(shang)(shang)所(suo)施加的(de)(de)電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya),因此常(chang)(chang)在高壓(ya)(ya)(ya)(ya)側接入FRC阻容(rong)分壓(ya)(ya)(ya)(ya)器(qi)來(lai)(lai)測量電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(見圖5)。
工(gong)頻耐壓試驗(yan)操作注意事項
1)試驗人員應做好分工(gong),明確相互間聯(lian)系方法。并(bing)有專門人監護現場(chang)**及觀(guan)察試品狀態(tai)。
2)被試(shi)(shi)品(pin)應先清掃干凈,并**干燥,以免(mian)損壞(huai)被試(shi)(shi)品(pin)和(he)試(shi)(shi)驗帶來的(de)誤差。
3)對于大型試(shi)(shi)驗,一般都應先進(jin)行空升(sheng)試(shi)(shi)驗。即(ji)不接試(shi)(shi)品時(shi)升(sheng)壓至試(shi)(shi)驗電壓,校對各(ge)種表計(ji),調整球間(jian)隙。
4)升(sheng)壓(ya)速度(du)不(bu)能太快,并必(bi)須防止突(tu)(tu)然加(jia)壓(ya)。例如調壓(ya)器不(bu)在零(ling)位時突(tu)(tu)然合閘(zha)。也不(bu)能突(tu)(tu)然切(qie)斷(duan)電源,一般應在調壓(ya)器降至零(ling)位時拉(la)閘(zha)。
5)當電(dian)壓升至試驗電(dian)壓時(shi),開(kai)始計時(shi),到1min后,迅(xun)速(su)降(jiang)壓到1/3試驗電(dian)壓以下時(shi),才能拉開(kai)電(dian)源。
6)在升壓或耐(nai)壓試驗過(guo)程中,如發(fa)現(xian)下列不正常情況時,應立即降壓,切斷電(dian)源。停止試驗并查明原因:①電(dian)壓表指針擺動很大(da);②發(fa)現(xian)絕緣燒焦或冒煙;③被(bei)試品內有(you)不正常的聲音。
7)耐壓試(shi)驗前后應測量絕(jue)緣電阻,檢查絕(jue)緣情況。
試驗變壓器在做(zuo)被試品的直流耐壓或泄露試驗時接線原理圖(tu)如圖(tu)6。
注:此試驗應(ying)先抽出短路桿“D”,圖6中所示。
圖中:VD—高壓(ya)硅堆 R1—限流(liu)電(dian)(dian)阻 C1—高壓(ya)濾波電(dian)(dian)容 FRC—阻容分壓(ya)器(qi) CX—被(bei)試品 μA—帶(dai)保護微安表
泄露試驗中限(xian)流(liu)(liu)電(dian)阻(zu)R1選擇在(zai)額定(ding)輸出電(dian)壓(ya)時,輸出端短路電(dian)流(liu)(liu)不超過高壓(ya)硅堆(dui)的(de)*大整流(liu)(liu)。如(ru)電(dian)壓(ya)硅堆(dui)的(de)*大整流(liu)(liu)電(dian)流(liu)(liu)為100mA時用于(yu)60kV的(de)試驗裝置中,限(xian)流(liu)(liu)電(dian)阻(zu)按R1=60/0.1=600kΩ選擇。限(xian)流(liu)(liu)電(dian)阻(zu)還應(ying)具有足夠(gou)的(de)容量和沿面(mian)放(fang)電(dian)距離。
高壓濾波電容C1一般選擇在0.01~0.1μF,當被試品的電容量很大(da)時,C1可省略不用。
泄(xie)露試驗的操作及(ji)注意事項
1)試(shi)驗前應先檢查(cha)被試(shi)品是否停(ting)電,接地(di)放電,一切對(dui)外連線是否擦(ca)干凈。要嚴防將試(shi)驗電壓加到有人工作的(de)部位(wei)上去。
2)接(jie)好試驗裝置的接(jie)線(xian)后(hou),應復查無(wu)誤后(hou)才可(ke)加(jia)壓(ya)(ya)。應特別注意檢查高壓(ya)(ya)設(she)備及引線(xian)與地、與操作人員的**距離(li),被試品(pin)的外殼是否可(ke)靠接(jie)地,要按**規(gui)程中所(suo)規(gui)定的內容進行(xing)試驗。
3)對于大電(dian)容量設備應緩慢升(sheng)壓(ya)(ya),防止被(bei)試(shi)品(pin)的(de)充電(dian)電(dian)流燒壞微(wei)安表。必(bi)要時應分級(ji)(ji)加壓(ya)(ya),分別讀取各級(ji)(ji)電(dian)壓(ya)(ya)下微(wei)安表的(de)穩定讀數。
4)試驗(yan)過程中,應密(mi)切監(jian)視被試品、試驗(yan)裝置、微安表,一旦(dan)發生擊穿、閃爍等(deng)異常現象應立即降壓,切斷電源,并(bing)查明(ming)原因,詳細記(ji)錄。
5)試(shi)驗(yan)完(wan)畢,降壓,切斷(duan)電(dian)源后應將被試(shi)品及(ji)試(shi)驗(yan)裝置本身充分放電(dian)。
四(si)、注意事(shi)項(xiang)
1、按照您所進行的(de)試驗接(jie)好工作線路。試驗變(bian)(bian)壓(ya)器的(de)外殼(ke)以及操作系統的(de)外殼(ke)必須可靠(kao)(kao)接(jie)地(di)。試驗變(bian)(bian)壓(ya)器高壓(ya)繞組的(de)X端(高壓(ya)尾)以及測量繞組的(de)F端必須可靠(kao)(kao)接(jie)地(di)。
2、做串級(ji)(ji)(ji)試驗時,**級(ji)(ji)(ji)、第三級(ji)(ji)(ji)試驗變壓(ya)(ya)(ya)器的(de)低(di)壓(ya)(ya)(ya)繞組的(de)X端,測量繞組的(de)F端以(yi)及(ji)高壓(ya)(ya)(ya)繞組的(de)X端(高壓(ya)(ya)(ya)尾)均接(jie)本級(ji)(ji)(ji)試驗變壓(ya)(ya)(ya)器的(de)外(wai)殼(ke)。**級(ji)(ji)(ji)、第三級(ji)(ji)(ji)試驗變壓(ya)(ya)(ya)器的(de)外(wai)殼(ke)必須通過絕緣(yuan)支架接(jie)地(di)。
3、接(jie)通電源前,操作系統的調壓(ya)器(qi)必須(xu)調到零(ling)位后方(fang)可接(jie)通電源,合閘,開(kai)始升壓(ya)。
4、從零開(kai)始均(jun)勻旋轉調壓(ya)(ya)器手輪升(sheng)(sheng)壓(ya)(ya)。升(sheng)(sheng)壓(ya)(ya)方法有:快(kuai)速(su)(su)升(sheng)(sheng)壓(ya)(ya)法,即20s逐級升(sheng)(sheng)壓(ya)(ya)法;慢速(su)(su)升(sheng)(sheng)壓(ya)(ya)法,即60s逐級升(sheng)(sheng)壓(ya)(ya)法;極慢速(su)(su)升(sheng)(sheng)壓(ya)(ya)法供選用(yong)。電(dian)壓(ya)(ya)從零開(kai)始按(an)一定的(de)(de)升(sheng)(sheng)壓(ya)(ya)方式和(he)速(su)(su)度(du)上升(sheng)(sheng)到您所需的(de)(de)額(e)(e)定試(shi)驗(yan)電(dian)壓(ya)(ya)的(de)(de)75%后(hou),在以每秒2%額(e)(e)定試(shi)驗(yan)電(dian)壓(ya)(ya)的(de)(de)速(su)(su)度(du)升(sheng)(sheng)到您所需的(de)(de)額(e)(e)定電(dian)壓(ya)(ya),并密切注意測量(liang)儀表的(de)(de)指(zhi)示(shi)以及被試(shi)品的(de)(de)情(qing)況(kuang)。升(sheng)(sheng)壓(ya)(ya)過程中(zhong)或試(shi)驗(yan)過程中(zhong)如發(fa)現(xian)測量(liang)儀表的(de)(de)指(zhi)示(shi)及被試(shi)品情(qing)況(kuang)異(yi)常,應(ying)立即降壓(ya)(ya),切斷電(dian)源(yuan),查(cha)明情(qing)況(kuang)。
5、試(shi)驗完(wan)畢后(hou),應在數秒內勻速的將調壓器返回至零(ling)位,然后(hou)切斷電源。
6、本產(chan)品不得(de)超過額定參數使用(yong)。除試驗必須外,決不允許全電壓通電或斷電。
7、 再升壓(ya)(ya)(ya)或耐(nai)壓(ya)(ya)(ya)試驗(yan)過程中,如發現以下不正常情況(kuang)時,應立即降壓(ya)(ya)(ya),切斷電源(yuan),停止(zhi)試驗(yan)并查(cha)明原因。
⑴電壓表指針擺動(或(huo)數字跳動)很大
⑵電流表直(zhi)線(xian)上升
被試品內有不(bu)正常的聲音
8、圖(tu)1中第9項系壓力閥及壓力表,為長(chang)期關(guan)閉(bi)狀態。每(mei)6個月開閥一(yi)次,以檢查(cha)SF6壓力,應不小于(yu)0.2MPa(檢查(cha)壓力后立即關(guan)閉(bi)閥門),低于(yu)0.2MPa時應加SF6氣體(ti),以增(zeng)加氣絕緣。
9、耐(nai)壓實驗前后應測量被試設備的絕緣電阻,檢查絕緣情況(kuang)。
10、當試驗變壓(ya)器長期(qi)不使用時,應放置于(yu)通風、干燥、無陽(yang)光(guang)直射的地方。
11、該產(chan)品(pin)不允許在(zai)高于45℃的溫度下長(chang)期(qi)存放(fang)、使(shi)用、放(fang)氣。
12、運(yun)輸搬運(yun)途(tu)中不得(de)重力沖擊。
13、產(chan)品(pin)緊固件及壓力閥、壓力表不得擅自松動(dong)。
14、使用(yong)本產(chan)品做高壓(ya)(ya)試(shi)(shi)驗時,出熟悉本說明(ming)書外(wai),還(huan)必須嚴格執行(xing)國家有關(guan)標準(zhun)和操作規(gui)程(cheng)。可(ke)參照GB311-83《高壓(ya)(ya)輸變設備的絕緣配(pei)合(he),高壓(ya)(ya)試(shi)(shi)驗技術》;《電氣設備預防性試(shi)(shi)驗規(gui)程(cheng)》等。
五、試驗變壓器的(de)容量(liang)選擇
標稱試驗變壓器容量(liang)Pn的確定公式:Pn=kVn 2ωCt×10-9
式(shi)中:
Pn——標稱試(shi)驗(yan)變(bian)壓(ya)器容量(kVA)
Vn——試驗變(bian)壓(ya)器的額(e)定輸出高壓(ya)的有效值(kV)
k ——**系數。k≥1,標稱電壓(ya)(ya)Vn≥1MV時,k=2;標稱電壓(ya)(ya)較低時,k值可取高一(yi)些。
Ct——被試品的電容量(pF)
ω——角頻率,ω=2πf,f——試驗電源的頻率
被試設備的電容(rong)量Ct可由交流電橋測出。Ct的變化很大,
可由設備(bei)的(de)類型而定。
典型數據如下:
簡單的棒式或懸式絕緣子 幾十微法(fa)
簡單的分級套管 100~1000pF
電(dian)壓互(hu)感器(qi) 200 ~ 500pF
電力變壓器 < 1000kVA~1000pF
> 1000kVA 1000~10000pF
高壓電力(li)電纜(lan)和油浸(jin)紙絕緣 250~300pF/m
氣體絕緣 ~60pF/m
封(feng)閉變電(dian)站,SF6氣體絕(jue)緣 100~10000Pf;
對于不同(tong)的試驗(yan)電壓Vn,選擇(ze)不同(tong)的(適當(dang)的)**系數k。
以下列出不同的Vn所選用的k值供參考。
Vn =50~100kV k = 4
Vn =150~300kV k = 3
Vn > 300kV k = 2
一、概述(shu)
工頻耐壓(ya)試驗是鑒定電(dian)力(li)(li)設備絕緣(yuan)強度的(de)(de)*嚴格(ge)、*有(you)(you)效和*直接的(de)(de)方法。它能(neng)檢查出那些危險性(xing)(xing)較大(da)的(de)(de)集中缺陷,對判斷電(dian)力(li)(li)設備能(neng)否繼(ji)續參(can)加(jia)運行具有(you)(you)決定性(xing)(xing)作用(yong),是保證設備絕緣(yuan)水平、避免(mian)發生絕緣(yuan)事故的(de)(de)重(zhong)要手段。
本裝置是根據國家(jia)*新(xin)電力行業標準而設(she)計的(de)、性能先進(jin)的(de)耐壓試(shi)驗設(she)備,用于對各種(zhong)電器產品、電氣元件、絕緣(yuan)材料等進(jin)行規(gui)定電壓下的(de)絕緣(yuan)強度試(shi)驗,以考核產品的(de)絕緣(yuan)水平(ping),發現(xian)被試(shi)品的(de)絕緣(yuan)缺(que)陷,衡(heng)量過電壓的(de)能力。
二(er)、產(chan)品特(te)點
監視功能:高(gao)壓(ya)電(dian)壓(ya) 低(di)壓(ya)電(dian)流 零(ling)位指示(shi) 電(dian)源指示(shi) 工作(zuo)指示(shi) 計時指示(shi)
保(bao)(bao)護功能(neng):過流保(bao)(bao)護、零(ling)位啟動保(bao)(bao)護、聲光語言報警提(ti)醒
采用新型(xing)時間繼電器(qi),計時范圍更廣(1S~99H)
采(cai)用新型電流(liu)繼電器,更**、更可(ke)靠(kao),確保人身及設備(bei)**。
試驗變壓器高壓線圈(quan)為圓筒多層塔式,由上等聚酯漆包(bao)線及高耐壓值(zhi)絕緣材料(liao)繞制而成。
試驗變壓器(qi)(5kVA以上)裝有可移(yi)動的鐵(tie)輪。具(ju)有重量輕、體積小(xiao)、移(yi)動方便、性能優越等(deng)特(te)點。
三、設備(bei)組成(cheng)
1、選(xuan)型配置
標準配置
|
□ 分體(ti)式
|
操作部分(fen):
□箱式(shi)(不(bu)大于(yu)5kVA) / □臺式(shi)
容量: kVA(小于200kVA)
輸(shu)入:□AC220V / □AC380V
|
試驗變壓器:
□交(jiao)流(liu) / □交(jiao)直流(liu)
□油變(bian) / □干變(bian) / □氣變(bian)
容量: kVA(小于200kVA)
輸出(chu):AC kV(小于(yu)300kVA)
|
□ 一體式
|
□箱式(不大于(yu)20kV) / □臺式(不大于(yu)30kV)
容量: kVA(小于300kVA)
輸入:□AC220V / □AC380V 輸出:AC kV(不大于30kV)
|
客戶選配
|
□標準高(gao)壓分壓器(qi)
|
□保護球隙
|
□直(zhi)流微安表
|
□放**
|
□保護(hu)水阻
|
□高壓(ya)濾波電(dian)容
|
其它:
|
2、對應(ying)實物
四、技術(shu)指標
1、使用條件:
(1)工(gong)作(zuo)場所應無嚴重影響絕緣(yuan)的氣體、蒸汽(qi)、化學性(xing)塵(chen)埃(ai)及其它爆炸性(xing)和(he)腐蝕(shi)性(xing)介質(zhi)。
(2)環境溫度 -20~+50℃
(3)環(huan)境(jing)濕(shi)度 ≤85% RH(無凝結水)
2、控制(zhi)箱(xiang)(臺(tai))參(can)數:(常規參(can)數見下(xia)表)
規格
|
容量
|
輸 入 電 源
|
輸(shu) 出 電(dian) 壓
|
重量(kg)
|
相數
|
(V)
|
(A)
|
(V)
|
(A)
|
2/220
|
2
|
1
|
220
|
10
|
0-250
|
8
|
14
|
3/220
|
3
|
1
|
220
|
15
|
0-250
|
12
|
16
|
5/220
|
5
|
1
|
220
|
25
|
0-250
|
20
|
18
|
10/220
|
10
|
1
|
220
|
50
|
0-250
|
40
|
80
|
15/380
|
15
|
2
|
380
|
37.5
|
0-430
|
34.8
|
90
|
20/380
|
20
|
2
|
380
|
50
|
0-430
|
46.5
|
100
|
25/380
|
25
|
2
|
380
|
62.5
|
0-430
|
58.1
|
120
|
30/380
|
30
|
2
|
380
|
75
|
0-430
|
69.7
|
140
|
50/380
|
50
|
2
|
380
|
125
|
0-430
|
116.2
|
160
|
100/380
|
100
|
2
|
380
|
250
|
0-430
|
232.5
|
250
|
說(shuo)明(ming):如有(you)特(te)殊參數要求,可(ke)按(an)用戶的技術參數進行設計(ji)制作。
3、試驗變壓器參數(shu):(常規參數(shu)見下表)
規格
|
容(rong)量(liang)
kVA
|
低壓側
|
高(gao)壓(ya)側
|
高壓側(ce)(交直流(liu)變壓器(qi))
|
測量變(bian)比
|
60分鐘溫升℃
|
阻抗電壓%
|
空載電流
%
|
質量(liang)
kg
|
電壓
V
|
電(dian)流(liu)
A
|
交流輸(shu)出
|
直(zhi)流輸出
|
電壓kV
|
電流
|
電(dian)壓(ya)kV
|
電(dian)流
|
1.5/50
|
1.5
|
200
|
7.5
|
50
|
30
|
70
|
21.4
|
500
|
50
|
10
|
<4
|
19.5
|
3/50
|
3
|
200
|
15
|
50
|
60
|
70
|
42.9
|
500
|
50
|
10
|
<4
|
27
|
5/50
|
5
|
200
|
25
|
50
|
100
|
70
|
71.4
|
500
|
50
|
10
|
<4
|
52
|
10/50
|
10
|
200
|
50
|
50
|
200
|
70
|
142.9
|
500
|
50
|
10
|
<4
|
80
|
15/50
|
15
|
400
|
37.5
|
50
|
300
|
70
|
214.3
|
500
|
50
|
8
|
<4
|
120
|
20/50
|
20
|
400
|
50
|
50
|
400
|
70
|
285.7
|
500
|
50
|
8
|
<4
|
140
|
30/50
|
30
|
400
|
75
|
50
|
600
|
70
|
428.6
|
500
|
50
|
8
|
<4
|
155
|
50/50
|
50
|
400
|
125
|
50
|
1000
|
70
|
714.3
|
500
|
50
|
8
|
<4
|
184
|
10/100
|
10
|
200
|
50
|
100
|
100
|
140
|
71.4
|
1000
|
50
|
10
|
<4
|
135
|
15/100
|
15
|
400
|
37.5
|
100
|
150
|
140
|
107.1
|
1000
|
50
|
8
|
<4
|
150
|
20/100
|
20
|
400
|
50
|
100
|
200
|
140
|
142.9
|
1000
|
50
|
8
|
<4
|
215
|
30/100
|
30
|
400
|
75
|
100
|
300
|
140
|
214.3
|
1000
|
50
|
8
|
<4
|
250
|
50/100
|
50
|
400
|
125
|
100
|
500
|
140
|
357.1
|
1000
|
50
|
8
|
<4
|
290
|
10/150
|
10
|
200
|
50
|
100
|
66.7
|
140
|
47.6
|
1500
|
50
|
10
|
<4
|
180
|
15/150
|
15
|
400
|
37.5
|
150
|
100
|
210
|
71.4
|
1500
|
50
|
8
|
<4
|
200
|
20/150
|
30
|
400
|
50
|
150
|
133.3
|
210
|
95.2
|
1500
|
50
|
8
|
<4
|
220
|
30/150
|
30
|
400
|
75
|
150
|
200
|
210
|
142.9
|
1500
|
50
|
8
|
<4
|
280
|
50/150
|
50
|
400
|
125
|
150
|
333.3
|
210
|
238.1
|
1500
|
50
|
8
|
<4
|
340
|
說明(ming):如有特殊參數要求,可按用(yong)戶的(de)技(ji)術參數進行設計(ji)制作。
上表的重量以油(you)浸式(shi)試驗(yan)變壓(ya)器(qi)為(wei)例(li),干式(shi)試驗(yan)變壓(ya)器(qi)和(he)充氣式(shi)試驗(yan)變壓(ya)器(qi)稍有不同。
五、接(jie)線及(ji)工作原理
1、調壓(ya)部分(fen)接線及原理(li)
調壓(ya)(ya)(ya)部(bu)分(fen)由控制(zhi)部(bu)分(fen)和試驗(yan)變(bian)壓(ya)(ya)(ya)器組成(cheng)。控制(zhi)部(bu)分(fen)是由接觸(chu)式調壓(ya)(ya)(ya)器及其控制(zhi)、保護、測量、信(xin)號(hao)電路組成(cheng)。試驗(yan)變(bian)壓(ya)(ya)(ya)器由低壓(ya)(ya)(ya)繞(rao)組、高壓(ya)(ya)(ya)繞(rao)組、儀表繞(rao)組三部(bu)分(fen)組成(cheng)。
試驗(yan)變(bian)(bian)壓(ya)器(qi)為交直(zhi)流(liu)兩用時,試驗(yan)變(bian)(bian)壓(ya)器(qi)配(pei)置(zhi)(zhi)(zhi)了高(gao)壓(ya)硅(gui)堆(dui)(油變(bian)(bian)、氣變(bian)(bian)為內置(zhi)(zhi)(zhi),干(gan)變(bian)(bian)為外置(zhi)(zhi)(zhi)),高(gao)壓(ya)可輸出(chu)交流(liu)和直(zhi)流(liu)。輸出(chu)交流(liu)時,要求(qiu)接入短(duan)路(lu)桿(油變(bian)(bian)、氣變(bian)(bian))或去(qu)掉外置(zhi)(zhi)(zhi)硅(gui)堆(dui)(干(gan)變(bian)(bian));輸出(chu)直(zhi)流(liu)時,要求(qiu)擰出(chu)短(duan)路(lu)桿(油變(bian)(bian)、氣變(bian)(bian))或加上外置(zhi)(zhi)(zhi)硅(gui)堆(dui)(干(gan)變(bian)(bian))
通過(guo)接(jie)入工(gong)頻(pin)電源,調節調壓器,以獲得所需要(yao)的試(shi)驗高壓電壓值。其工(gong)作原理見圖1:
2、試(shi)驗部分接線及(ji)原理
做耐壓試驗時(shi),控(kong)制(zhi)部(bu)分(fen)(fen)、變壓器的接(jie)地端及高(gao)(gao)壓尾必須(xu)可靠(kao)接(jie)地。有條件(jian)的情況下,做工頻耐壓試驗請(qing)加上(shang)限流電(dian)阻(zu)、標準(zhun)高(gao)(gao)壓分(fen)(fen)壓器、球隙保護電(dian)阻(zu)及保護球隙,如(ru)圖3。
做直流耐壓(ya)試(shi)驗請另外(wai)加(jia)上(shang)微(wei)安(an)(an)表,微(wei)安(an)(an)表必須(xu)接在(zai)(zai)硅堆(dui)和(he)被試(shi)器之間,油(you)變(bian)(bian)或氣變(bian)(bian)一般(ban)擰(ning)在(zai)(zai)高壓(ya)頭上(shang)面(要求(qiu)擰(ning)出(chu)短路桿),干(gan)變(bian)(bian)擰(ning)在(zai)(zai)外(wai)置(zhi)硅堆(dui)上(shang)面;為了更(geng)準確顯示高壓(ya)直流泄(xie)漏電流,請將(jiang)分壓(ya)器的高壓(ya)線(xian)接在(zai)(zai)微(wei)安(an)(an)表和(he)硅堆(dui)之間,(油(you)變(bian)(bian)、氣變(bian)(bian))如圖4,(干(gan)變(bian)(bian))如圖5。
耐壓(ya)(ya)試驗中(zhong)限流(liu)(liu)電(dian)(dian)阻(zu)(zu)R1應根據試驗變(bian)壓(ya)(ya)器的(de)額定容量(liang)(liang)來選擇。如高壓(ya)(ya)側(ce)額定輸出電(dian)(dian)流(liu)(liu)在100~300mA時,可(ke)取0.5~1Ω/V(試驗電(dian)(dian)壓(ya)(ya));高壓(ya)(ya)側(ce)額定輸出電(dian)(dian)流(liu)(liu)為1A以上(shang)時,可(ke)取1Ω/V(試驗電(dian)(dian)壓(ya)(ya))。常(chang)用水(shui)電(dian)(dian)阻(zu)(zu)作(zuo)為限流(liu)(liu)電(dian)(dian)阻(zu)(zu),管(guan)子長度(du)可(ke)按(an)150kV/m考(kao)慮,管(guan)子粗細應具(ju)有足(zu)夠的(de)熱容量(liang)(liang)(水(shui)阻(zu)(zu)液(ye)配制(zhi)方法:用蒸餾水(shui)加入(ru)適量(liang)(liang)硫酸銅配制(zhi)成各種不同的(de)阻(zu)(zu)值)。
球間隙(xi)(xi)及(ji)保護電阻:當電壓(ya)超(chao)過球間隙(xi)(xi)整定值時(shi)(一般取(qu)試(shi)(shi)驗電壓(ya)的(de)110%~120%),球間隙(xi)(xi)放電,對被試(shi)(shi)品起到保護作用。球間隙(xi)(xi)保護電阻可按1Ω/V(試(shi)(shi)驗電壓(ya))選取(qu)。
在(zai)(zai)工頻耐壓(ya)(ya)(ya)試(shi)驗中,低電(dian)壓(ya)(ya)(ya)側測(ce)量電(dian)壓(ya)(ya)(ya)(儀表(biao)電(dian)壓(ya)(ya)(ya))不是非(fei)常準(zhun)確的(de),其原因是由于試(shi)驗變(bian)壓(ya)(ya)(ya)器(qi)存在(zai)(zai)著漏抗,在(zai)(zai)這個(ge)漏抗上必然(ran)存在(zai)(zai)著壓(ya)(ya)(ya)降或(huo)容升(sheng),使(shi)試(shi)品上的(de)電(dian)壓(ya)(ya)(ya)低于或(huo)高(gao)于低壓(ya)(ya)(ya)側測(ce)量電(dian)壓(ya)(ya)(ya)表(biao)上反(fan)映出來的(de)電(dian)壓(ya)(ya)(ya)。工頻耐壓(ya)(ya)(ya)試(shi)驗時,被(bei)試(shi)品上的(de)電(dian)壓(ya)(ya)(ya)高(gao)于試(shi)驗變(bian)壓(ya)(ya)(ya)器(qi)的(de)輸出電(dian)壓(ya)(ya)(ya),也就是所謂容升(sheng)現象。感(gan)應(ying)耐壓(ya)(ya)(ya)試(shi)驗時,試(shi)驗變(bian)壓(ya)(ya)(ya)器(qi)的(de)漏抗必然(ran)存在(zai)(zai)著壓(ya)(ya)(ya)降。為了準(zhun)確測(ce)量被(bei)試(shi)品上所施(shi)加的(de)電(dian)壓(ya)(ya)(ya),因此常在(zai)(zai)高(gao)壓(ya)(ya)(ya)側接入標準(zhun)高(gao)壓(ya)(ya)(ya)分(fen)壓(ya)(ya)(ya)器(qi)來測(ce)量電(dian)壓(ya)(ya)(ya)。
五、面板結構說明
1、操作(zuo)箱面板
控制(zhi)箱(xiang)為箱(xiang)式(shi)鋁(lv)合(he)金(jin)(jin)結構,面板(ban)采(cai)用拉(la)絲鋁(lv)合(he)金(jin)(jin)工藝(yi),所有電器元件均裝在骨(gu)架上(shang),便于安(an)裝和維(wei)修。面板(ban)元件布置如下:
2、操作臺面板
操(cao)作臺為臺式結(jie)構(gou),殼體為冷扎鋼板結(jie)構(gou),面板采用鋁合金(jin)拉絲工藝(yi),面板元件布置如下:
六、操作指南
本裝置在操作之前應根(gen)據(ju)不同被試品的(de)容量(liang)、電壓等級,先計算好(hao)*大工作電流,并調整(zheng)電流保護(hu)器(qi)。其試驗接線應參考本說明(ming)書中圖(tu)1、圖(tu)2、圖(tu)3、圖(tu)4、圖(tu)5,必須可靠接地。
1、操作(zuo)要點
(1)試(shi)(shi)驗(yan)前,應(ying)了(le)解被(bei)試(shi)(shi)品的(de)試(shi)(shi)驗(yan)電壓,同時(shi)了(le)解被(bei)試(shi)(shi)品的(de)其他試(shi)(shi)驗(yan)項目及以(yi)前的(de)試(shi)(shi)驗(yan)結果。若被(bei)試(shi)(shi)品有(you)缺陷或異常(chang),應(ying)在消除后(hou)再進(jin)行耐壓試(shi)(shi)驗(yan)。
(2)試驗現場(chang)應圍好遮攔(lan)或圍繩,掛好標示牌,并派專人監護。
(3)試(shi)驗(yan)前(qian),被(bei)(bei)試(shi)品(pin)表(biao)面應擦拭干(gan)凈,將被(bei)(bei)試(shi)品(pin)的(de)外殼和非被(bei)(bei)試(shi)繞組(zu)可靠接地。被(bei)(bei)試(shi)品(pin)為(wei)新沖油(you)設(she)備時(shi),應按(an)《規程(cheng)》規定使油(you)靜止一定時(shi)間(jian)再升壓,對110kV及(ji)以(yi)下的(de)充油(you)電(dian)力(li)設(she)備,在(zai)注(zhu)滿油(you)后靜置(zhi)(zhi)時(shi)間(jian)應不(bu)少于24小(xiao)時(shi),對220kV及(ji)330kV的(de)充油(you)電(dian)力(li)設(she)備,靜置(zhi)(zhi)時(shi)間(jian)應不(bu)少于48小(xiao)時(shi)。
(4)接好試驗(yan)接線后(hou),應由有(you)經(jing)驗(yan)的人員檢查(cha),確認(ren)無誤后(hou)方(fang)可升壓(ya)。
(5)升(sheng)壓(ya)前,首先檢(jian)查調壓(ya)器(qi)(qi)是否在零位。調壓(ya)器(qi)(qi)在零位方可升(sheng)壓(ya)。
(6)升壓(ya)(ya)過程(cheng)中不僅要監視電(dian)壓(ya)(ya)表的(de)變化(hua),還(huan)應監視電(dian)流(liu)表的(de)變化(hua),以及被試(shi)品電(dian)流(liu)的(de)變化(hua)。升壓(ya)(ya)時(shi)要均勻(yun)升壓(ya)(ya),不能太快(kuai)。升至規定試(shi)驗電(dian)壓(ya)(ya)時(shi),開始(shi)計算(suan)時(shi)間(jian),時(shi)間(jian)到后,緩慢均勻(yun)降下(xia)電(dian)壓(ya)(ya)。絕不允許(xu)不降壓(ya)(ya)就先跳開電(dian)源開關。
(7)試驗中發(fa)現表針擺動或(huo)被(bei)試品有異常(chang)聲響(xiang)、冒煙等應立即降(jiang)下電壓(ya),拉(la)開電源(yuan),在(zai)高壓(ya)側掛上(shang)接地(di)線后,再(zai)查(cha)明原(yuan)因。
(8)耐壓試(shi)驗前后均應(ying)測量被試(shi)品(pin)的(de)絕緣(yuan)電(dian)阻。
2、操(cao)作步驟(zou)
(1) 按試(shi)驗要求將控制部(bu)分、試(shi)驗變(bian)壓(ya)器(qi)、被試(shi)品正(zheng)確接(jie)好線,必須可靠接(jie)地,請參考圖(tu)1、圖(tu)2、圖(tu)3、圖(tu)4、圖(tu)5。
(2) 根(gen)據試驗的要求,整(zheng)定“時間(jian)繼電器”及“過流繼電器”。
A 時間繼(ji)電(dian)器設置:
T1,T2,T3,T4設置(zhi)(zhi)0~9任意(yi)數(shu)字,T可(ke)設置(zhi)(zhi)為(wei)H(小時),M(分鐘),S(秒)。
根據試驗要(yao)求,在1S~99H內(nei)可(ke)以任意設置(zhi)定時時間(jian)。
B 過流(liu)繼電器設(she)置:
過(guo)流(liu)動作設定(ding)值(zhi)=過(guo)流(liu)繼電(dian)器(qi)(qi)(qi)刻度盤(pan)讀(du)數×測量(liang)變(bian)(bian)比×K,其中K為(wei)(wei)電(dian)流(liu)倍(bei)率(lv)/切除開關(guan)的狀態值(zhi),分別為(wei)(wei)X1,X2,OFF,電(dian)流(liu)倍(bei)率(lv)/切除開關(guan)處于(yu)×1,×2位置(zhi)時(shi),K值(zhi)分別為(wei)(wei)1、2,切換為(wei)(wei)OFF擋(dang)時(shi),K值(zhi)為(wei)(wei)+∞。(注:不要使(shi)(shi)用(yong)OFF檔,因為(wei)(wei)會使(shi)(shi)變(bian)(bian)壓器(qi)(qi)(qi)失(shi)去過(guo)流(liu)保護(hu)功能而導致設備(bei)損壞(huai)。測量(liang)變(bian)(bian)比為(wei)(wei)電(dian)流(liu)互感器(qi)(qi)(qi)的變(bian)(bian)比,沒(mei)有電(dian)流(liu)互感器(qi)(qi)(qi)時(shi)為(wei)(wei)1)。
(3) 接入電(dian)(dian)(dian)源,此(ci)時,“電(dian)(dian)(dian)源燈(deng)”亮(liang),表(biao)示外部電(dian)(dian)(dian)源已引(yin)入。如“零(ling)位(wei)(wei)燈(deng)”亮(liang),表(biao)示調壓器在零(ling)位(wei)(wei)。如“零(ling)位(wei)(wei)燈(deng)”不亮(liang),應逆時針(zhen)旋轉(zhuan)調節(jie)調壓器手(shou)柄至“零(ling)位(wei)(wei)燈(deng)”亮(liang),表(biao)示可進(jin)行調壓操作。
(4)按“啟(qi)動(dong)按鈕”。此(ci)時,“送(song)電(dian)燈(deng)”,“電(dian)源燈(deng)”和“零位燈(deng)”亮(liang);進(jin)入送(song)電(dian)狀態。
(5)以2kV/S勻速順(shun)時(shi)(shi)針旋(xuan)轉調壓器手柄至(zhi)被試(shi)(shi)品規定(ding)的耐壓值,并(bing)密切注(zhu)視電流(liu)表(biao)(直流(liu)耐壓試(shi)(shi)驗時(shi)(shi),同(tong)時(shi)(shi)密切注(zhu)視直流(liu)微(wei)安表(biao))。此時(shi)(shi),“電源燈(deng)”,“工作燈(deng)”亮;“零位(wei)燈(deng)”滅。
(6)根(gen)據試驗(yan)啟動“計(ji)時(shi)按鈕”,計(ji)時(shi)開始,并注意被試品的(de)情況。
(7)當(dang)耐壓計(ji)時到時,操(cao)作(zuo)臺自動聲光報警。應立即逆時針旋(xuan)轉(zhuan)調壓器(qi)手柄至(zhi)零(ling)位(wei)(wei),按(an)下停止(zhi)按(an)鈕和解除計(ji)時按(an)鈕自鎖(suo)狀態。此時“電源(yuan)燈(deng)(deng)”, “零(ling)位(wei)(wei)燈(deng)(deng)”亮,“工作(zuo)燈(deng)(deng)”滅。試驗即告完畢
(8)拔掉電(dian)源,拆除接線,試驗結束。
(9)在升(sheng)壓或耐壓過(guo)程中,如發生(sheng)短路(lu)、閃絡、擊穿過(guo)流時,過(guo)流繼(ji)電器動作,切斷(duan)(duan)主回路(lu)。此時應(ying)將調壓器逆時針旋轉至(zhi)零位,切斷(duan)(duan)電源,并查明原因,并作詳(xiang)細(xi)記錄。
(10)試(shi)驗完畢(bi),降壓,切斷電源后應用放**將被試(shi)品及(ji)試(shi)驗裝置本(ben)身充分放電。
七、產品維護
1、開箱驗收時,應檢查主控(kong)回路(lu)接線是否(fou)松動,調壓(ya)器電刷是否(fou)接觸良好;
2、長期不用(yong)時,使用(yong)前應用(yong)500V兆歐表測量絕緣電阻,其阻值不低于0.5MΩ;
3、電源電壓應符合控制箱(臺)銘牌上的輸入電壓值;
4、本裝(zhuang)置設(she)有過電流(liu)保護(hu),出廠已調整為額定電流(liu)的50%。用于小負載時,應根據被(bei)試品的額定容量電流(liu)重新設(she)定;
5、使用完畢后,應關好控(kong)制箱(臺(tai))門,以保持控(kong)制箱(臺(tai))內部清潔(jie)。
八、注(zhu)意事項
1、按照您所進(jin)行的(de)試(shi)(shi)驗(yan)接(jie)(jie)好工(gong)作(zuo)線(xian)路(lu)。試(shi)(shi)驗(yan)變(bian)壓(ya)器(qi)的(de)外殼以及操作(zuo)系統的(de)外殼必須可靠接(jie)(jie)地(di)。試(shi)(shi)驗(yan)變(bian)壓(ya)器(qi)的(de)高(gao)壓(ya)繞(rao)組的(de)X端(高(gao)壓(ya)尾)以及測(ce)量(liang)繞(rao)組的(de)F端必須可靠接(jie)(jie)地(di)。
2、做串級(ji)試(shi)(shi)驗時,**級(ji)、第(di)(di)三級(ji)試(shi)(shi)驗變壓(ya)器的低壓(ya)繞(rao)組成X端,測量繞(rao)組的F端以(yi)及高壓(ya)繞(rao)組的X端(高壓(ya)端)均接本級(ji)試(shi)(shi)驗變壓(ya)器具外(wai)殼。**級(ji)、第(di)(di)三級(ji)試(shi)(shi)驗變壓(ya)器的外(wai)殼必(bi)須通過絕緣支架(jia)接地。
3、接(jie)(jie)通(tong)電源前,操作(zuo)系統的(de)調壓(ya)(ya)器必須(xu)調到(dao)零位后(hou)方(fang)可(ke)接(jie)(jie)通(tong)電源,合閘,開始升(sheng)壓(ya)(ya)。從零開始勻速(su)(su)旋轉調壓(ya)(ya)器手(shou)輪升(sheng)壓(ya)(ya)。升(sheng)壓(ya)(ya)方(fang)式(shi)有:快速(su)(su)升(sheng)壓(ya)(ya)法(fa),即20s逐級(ji)(ji)升(sheng)壓(ya)(ya)法(fa);慢速(su)(su)升(sheng)壓(ya)(ya)法(fa),即60s逐級(ji)(ji)升(sheng)壓(ya)(ya)法(fa);極慢速(su)(su)升(sheng)壓(ya)(ya)法(fa)供選用。電壓(ya)(ya)從零開始按一定(ding)的(de)升(sheng)壓(ya)(ya)方(fang)式(shi)和(he)速(su)(su)度上(shang)升(sheng)到(dao)您所(suo)需(xu)的(de)額定(ding)試驗電壓(ya)(ya)的(de)75%后(hou),再以每秒2%額定(ding)試驗電壓(ya)(ya)的(de)速(su)(su)度升(sheng)到(dao)您所(suo)需(xu)的(de)試驗電壓(ya)(ya),并密切(qie)注意測(ce)量儀(yi)表的(de)及被試品(pin)的(de)情(qing)(qing)況(kuang)。升(sheng)壓(ya)(ya)過(guo)(guo)程(cheng)中(zhong)或試驗過(guo)(guo)程(cheng)中(zhong)如發現測(ce)量儀(yi)表的(de)指(zhi)示及被試品(pin)情(qing)(qing)況(kuang)異常,應立即降壓(ya)(ya),切(qie)斷電源,查明情(qing)(qing)況(kuang)。
4、試驗(yan)完畢后,應在(zai)數秒內勻(yun)速(su)的將調壓器返回至零位,然后切斷電源。本產(chan)品不得(de)超過額定(ding)參數使用(yong)。
5、使(shi)用本產品做高(gao)壓(ya)試(shi)(shi)驗(yan)時,除熟(shu)悉本說明書外,還(huan)必須嚴格執行(xing)國家有關標準和操(cao)作(zuo)規(gui)程(cheng)。可參照GB311.1 – 97《高(gao)壓(ya)輸變設備的絕(jue)緣配合,高(gao)壓(ya)試(shi)(shi)驗(yan)技術》;《電氣設備預防性試(shi)(shi)驗(yan)規(gui)程(cheng)》等(deng)
一、概(gai)述
智能(neng)(neng)耐壓試(shi)驗(yan)裝(zhuang)置是根據國(guo)家(jia)*新電(dian)(dian)(dian)(dian)力(li)行業標準而設計(ji)的(de)、性能(neng)(neng)先(xian)進(jin)的(de)智能(neng)(neng)型耐壓試(shi)驗(yan)設備,用于(yu)對各(ge)種電(dian)(dian)(dian)(dian)器產(chan)品(pin)、電(dian)(dian)(dian)(dian)氣元件、絕緣材(cai)料等進(jin)行規定電(dian)(dian)(dian)(dian)壓下的(de)絕緣強度試(shi)驗(yan),以(yi)考核(he)產(chan)品(pin)的(de)絕緣水平,發現(xian)被試(shi)品(pin)的(de)絕緣缺陷,衡量過電(dian)(dian)(dian)(dian)壓的(de)能(neng)(neng)力(li)。廣泛應(ying)用于(yu)電(dian)(dian)(dian)(dian)工(gong)制造部(bu)門(men)、電(dian)(dian)(dian)(dian)力(li)運行部(bu)門(men)、科研單位和高等院校。
二、產品(pin)特點(dian)
1. 320×240液晶顯示器、高速熱敏(min)打印(yin)機。
2. 高壓(ya)電(dian)壓(ya)、高壓(ya)電(dian)流(liu)、低(di)壓(ya)電(dian)壓(ya)、低(di)壓(ya)電(dian)流(liu)4路(lu)測量方式,高精度傳(chuan)感(gan)器和(he)高性能14位AD采(cai)集(ji)芯片。
3. 人機(ji)對話全鍵(jian)盤操作(zuo)方式,智能化工(gong)作(zuo)全過程,任(ren)選(xuan)自動方式和手動方式。
4. 實時顯示高(gao)壓電壓、高(gao)壓電流、低壓電壓、低壓電流,時間及耐壓結果,顯示直觀明了。
5. 完善(shan)的過(guo)壓(ya)、過(guo)流保(bao)護,任意設定輸出(chu)電(dian)壓(ya)、高壓(ya)電(dian)流上限、低壓(ya)電(dian)流上限和計時(shi)時(shi)間。
6. 具有(you)回零檢(jian)測功能(neng),回零確定后才可進行(xing)試(shi)驗(yan),**可靠(kao)。
7. 具(ju)有絕(jue)緣(yuan)電阻測試(shi)功能,直接反映被試(shi)品絕(jue)緣(yuan)強度。
8. 逼(bi)近式調(diao)壓(ya)算法,到達設定電壓(ya)后(hou)自(zi)動(dong)耐壓(ya)計時,計時結束后(hou)自(zi)動(dong)降壓(ya)回零。
9. 超過設定高(gao)壓(ya)(ya)(ya)電流(liu)(liu)或低壓(ya)(ya)(ya)電流(liu)(liu)時自動切斷電壓(ya)(ya)(ya)輸出(chu),降壓(ya)(ya)(ya)回零,并(bing)發(fa)生(sheng)聲光報警。
10. 精良的軟硬(ying)件抗干擾設計,多種抗干擾手段,適應惡劣電(dian)磁環境(jing)。
11. 自(zi)動錯(cuo)誤診斷,易于發現和解決問題。
12. 可選配無(wu)線(xian)遙(yao)控(kong)控(kong)制功(gong)能、遠程通信(xin)、門聯(lian)鎖警鈴、外接分壓器校(xiao)驗(yan)接口(kou)等。
三(san)、設備組(zu)成
1、選型(xing)配(pei)置
標(biao)準配置(zhi)
|
□ 分體式
|
操作部分:
□箱式(不大于5kVA) / □臺式
容量(liang): kVA(小(xiao)于200kVA)
輸入:□AC220V / □AC380V
|
試驗(yan)變(bian)壓(ya)器:
□交流 / □交直流
□油變(bian) / □干變(bian) / □氣變(bian)
容量(liang): kVA(小于(yu)200kVA)
輸出(chu):AC kV(小于(yu)300kVA)
|
□ 一體(ti)式
|
□箱式(不(bu)大于(yu)(yu)20kV) / □臺式(不(bu)大于(yu)(yu)30kV)
容量: kVA(小(xiao)于300kVA)
輸入(ru):□AC220V / □AC380V 輸出:AC kV(不大于30kV)
|
客戶選配
|
□標準高壓(ya)分壓(ya)器
|
□保護球隙
|
□直流微安(an)表
|
□放**
|
□保護水阻(zu)
|
□高壓濾(lv)波電容(rong)
|
其它:
|
2、對應(ying)實物
四、技術指標(biao)
1、使用條(tiao)件(jian):
(1)工作場所應無嚴重影響絕緣的氣體、蒸汽、化學性塵(chen)埃及(ji)其(qi)它爆炸性和(he)腐蝕性介質。
(2)環境溫度 -20~+50℃
(3)環境濕度 ≤85% RH(無(wu)凝(ning)結(jie)水(shui))
2、控(kong)制箱(臺)參數:(常規參數見下表)
(1)計時范圍:0-999S
(3)電壓精(jing)度 ≤1.5% ±1個字(F.S)
(4)電(dian)流精度 ≤1.5% ±1個字(F.S)
規格
|
容量
|
輸(shu) 入 電 源(yuan)
|
輸(shu) 出(chu) 電 壓
|
重量(liang)(kg)
|
相數
|
(V)
|
(A)
|
(V)
|
(A)
|
2/220
|
2
|
1
|
220
|
10
|
0-250
|
8
|
14
|
3/220
|
3
|
1
|
220
|
15
|
0-250
|
12
|
16
|
5/220
|
5
|
1
|
220
|
25
|
0-250
|
20
|
18
|
10/220
|
10
|
1
|
220
|
50
|
0-250
|
40
|
80
|
15/380
|
15
|
2
|
380
|
37.5
|
0-430
|
34.8
|
90
|
20/380
|
20
|
2
|
380
|
50
|
0-430
|
46.5
|
100
|
25/380
|
25
|
2
|
380
|
62.5
|
0-430
|
58.1
|
120
|
30/380
|
30
|
2
|
380
|
75
|
0-430
|
69.7
|
140
|
50/380
|
50
|
2
|
380
|
125
|
0-430
|
116.2
|
160
|
100/380
|
100
|
2
|
380
|
250
|
0-430
|
232.5
|
250
|
說明:如有特(te)殊(shu)參(can)數要(yao)求,可按用戶的技術參(can)數進行(xing)設計制作。
3、試(shi)驗變壓器(qi)參(can)數(shu):(常規參(can)數(shu)見下表(biao))
規格
|
容量
kVA
|
低壓側
|
高壓(ya)側
|
高壓(ya)(ya)側(交直(zhi)流(liu)變壓(ya)(ya)器)
|
測量變比
|
60分鐘溫升℃
|
阻抗(kang)電(dian)壓(ya)%
|
空(kong)載電流(liu)
%
|
質(zhi)量
kg
|
電壓
V
|
電流
A
|
交流(liu)輸出
|
直流輸(shu)出
|
電(dian)壓(ya)kV
|
電流
|
電壓kV
|
電流
|
1.5/50
|
1.5
|
200
|
7.5
|
50
|
30
|
70
|
21.4
|
500
|
50
|
10
|
<4
|
19.5
|
3/50
|
3
|
200
|
15
|
50
|
60
|
70
|
42.9
|
500
|
50
|
10
|
<4
|
27
|
5/50
|
5
|
200
|
25
|
50
|
100
|
70
|
71.4
|
500
|
50
|
10
|
<4
|
52
|
10/50
|
10
|
200
|
50
|
50
|
200
|
70
|
142.9
|
500
|
50
|
10
|
<4
|
80
|
15/50
|
15
|
400
|
37.5
|
50
|
300
|
70
|
214.3
|
500
|
50
|
8
|
<4
|
120
|
20/50
|
20
|
400
|
50
|
50
|
400
|
70
|
285.7
|
500
|
50
|
8
|
<4
|
140
|
30/50
|
30
|
400
|
75
|
50
|
600
|
70
|
428.6
|
500
|
50
|
8
|
<4
|
155
|
50/50
|
50
|
400
|
125
|
50
|
1000
|
70
|
714.3
|
500
|
50
|
8
|
<4
|
184
|
10/100
|
10
|
200
|
50
|
100
|
100
|
140
|
71.4
|
1000
|
50
|
10
|
<4
|
135
|
15/100
|
15
|
400
|
37.5
|
100
|
150
|
140
|
107.1
|
1000
|
50
|
8
|
<4
|
150
|
20/100
|
20
|
400
|
50
|
100
|
200
|
140
|
142.9
|
1000
|
50
|
8
|
<4
|
215
|
30/100
|
30
|
400
|
75
|
100
|
300
|
140
|
214.3
|
1000
|
50
|
8
|
<4
|
250
|
50/100
|
50
|
400
|
125
|
100
|
500
|
140
|
357.1
|
1000
|
50
|
8
|
<4
|
290
|
10/150
|
10
|
200
|
50
|
100
|
66.7
|
140
|
47.6
|
1500
|
50
|
10
|
<4
|
180
|
15/150
|
15
|
400
|
37.5
|
150
|
100
|
210
|
71.4
|
1500
|
50
|
8
|
<4
|
200
|
20/150
|
30
|
400
|
50
|
150
|
133.3
|
210
|
95.2
|
1500
|
50
|
8
|
<4
|
220
|
30/150
|
30
|
400
|
75
|
150
|
200
|
210
|
142.9
|
1500
|
50
|
8
|
<4
|
280
|
50/150
|
50
|
400
|
125
|
150
|
333.3
|
210
|
238.1
|
1500
|
50
|
8
|
<4
|
340
|
說明:如(ru)有(you)特殊參(can)數(shu)要求(qiu),可按用戶的(de)技(ji)術參(can)數(shu)進行(xing)設計制作。
上表的重量以油浸式試(shi)驗變(bian)壓(ya)器為(wei)例(li),干式試(shi)驗變(bian)壓(ya)器和(he)充氣式試(shi)驗變(bian)壓(ya)器稍有不(bu)同。
五、接線及工作原理
1、調壓部分接線(xian)及原(yuan)理
調(diao)壓部分(fen)由(you)控(kong)制部分(fen)和試驗變壓器(qi)組(zu)成(cheng)。控(kong)制部分(fen)是(shi)由(you)接觸式調(diao)壓器(qi)、單(dan)片(pian)機控(kong)制系統、液晶、打印機、信號測量、電路(lu)保護組(zu)成(cheng)。試驗變壓器(qi)由(you)低壓繞(rao)組(zu)、高壓繞(rao)組(zu)、儀表繞(rao)組(zu)三部分(fen)組(zu)成(cheng)。
試(shi)驗(yan)變(bian)壓(ya)器為(wei)交直流(liu)兩用(yong)時(shi),試(shi)驗(yan)變(bian)壓(ya)器配置(zhi)了高壓(ya)硅(gui)(gui)堆(油(you)變(bian)、氣變(bian)為(wei)內(nei)置(zhi),干變(bian)為(wei)外置(zhi)),高壓(ya)可輸出(chu)(chu)交流(liu)和直流(liu)。輸出(chu)(chu)交流(liu)時(shi),要求接入短路桿(gan)(油(you)變(bian)、氣變(bian))或去掉外置(zhi)硅(gui)(gui)堆(干變(bian));輸出(chu)(chu)直流(liu)時(shi),要求擰出(chu)(chu)短路桿(gan)(油(you)變(bian)、氣變(bian))或加上(shang)外置(zhi)硅(gui)(gui)堆(干變(bian))
通(tong)過接(jie)入工(gong)頻電(dian)源,調節調壓器,以獲得所需要(yao)的試驗高壓電(dian)壓值(zhi)。其工(gong)作原理見圖1:
2、試驗部(bu)分接線及原(yuan)理(li)
做耐壓(ya)(ya)(ya)試(shi)驗(yan)時(shi),控制(zhi)部(bu)分(fen)、變壓(ya)(ya)(ya)器的接(jie)地端及(ji)高壓(ya)(ya)(ya)尾必須可靠接(jie)地。有條件(jian)的情況下(xia),做工頻耐壓(ya)(ya)(ya)試(shi)驗(yan)請加上限流電阻(zu)、標準高壓(ya)(ya)(ya)分(fen)壓(ya)(ya)(ya)器、球(qiu)隙保護(hu)電阻(zu)及(ji)保護(hu)球(qiu)隙,如(ru)圖3。
做直流(liu)耐壓(ya)(ya)試(shi)(shi)驗(yan)請(qing)另外加上(shang)微(wei)安表,微(wei)安表必須(xu)接(jie)在硅堆和被(bei)試(shi)(shi)器(qi)之(zhi)間(jian),油(you)變(bian)或氣變(bian)一般擰(ning)在高壓(ya)(ya)頭上(shang)面(mian)(要求擰(ning)出短路桿),干變(bian)擰(ning)在外置(zhi)硅堆上(shang)面(mian);為(wei)了更準確顯示(shi)高壓(ya)(ya)直流(liu)泄(xie)漏電(dian)流(liu),請(qing)將分壓(ya)(ya)器(qi)的高壓(ya)(ya)線接(jie)在微(wei)安表和硅堆之(zhi)間(jian),(油(you)變(bian)、氣變(bian))如圖4,(干變(bian))如圖5。
耐壓(ya)試(shi)驗(yan)(yan)(yan)中(zhong)限(xian)流(liu)電(dian)(dian)(dian)阻(zu)R1應根(gen)據試(shi)驗(yan)(yan)(yan)變壓(ya)器的(de)(de)額定(ding)容量來選(xuan)擇(ze)。如高(gao)(gao)壓(ya)側額定(ding)輸出(chu)電(dian)(dian)(dian)流(liu)在100~300mA時,可取0.5~1Ω/V(試(shi)驗(yan)(yan)(yan)電(dian)(dian)(dian)壓(ya));高(gao)(gao)壓(ya)側額定(ding)輸出(chu)電(dian)(dian)(dian)流(liu)為1A以上(shang)時,可取1Ω/V(試(shi)驗(yan)(yan)(yan)電(dian)(dian)(dian)壓(ya))。常用水(shui)電(dian)(dian)(dian)阻(zu)作(zuo)為限(xian)流(liu)電(dian)(dian)(dian)阻(zu),管子(zi)長度(du)可按150kV/m考慮,管子(zi)粗(cu)細應具有足夠的(de)(de)熱容量(水(shui)阻(zu)液配(pei)制方(fang)法:用蒸(zheng)餾水(shui)加入適(shi)量硫酸銅配(pei)制成各種不(bu)同的(de)(de)阻(zu)值(zhi))。
球間隙及保護(hu)電(dian)(dian)阻:當(dang)電(dian)(dian)壓(ya)(ya)超過球間隙整(zheng)定值時(shi)(一般取試(shi)驗電(dian)(dian)壓(ya)(ya)的110%~120%),球間隙放(fang)電(dian)(dian),對(dui)被(bei)試(shi)品起到保護(hu)作用(yong)。球間隙保護(hu)電(dian)(dian)阻可按(an)1Ω/V(試(shi)驗電(dian)(dian)壓(ya)(ya))選取。
在工頻耐壓(ya)(ya)試(shi)(shi)驗(yan)中,低電(dian)(dian)(dian)壓(ya)(ya)側(ce)測量(liang)電(dian)(dian)(dian)壓(ya)(ya)(儀表電(dian)(dian)(dian)壓(ya)(ya))不是(shi)非常準確的(de),其原(yuan)因是(shi)由于(yu)試(shi)(shi)驗(yan)變壓(ya)(ya)器存(cun)在著(zhu)漏(lou)抗(kang),在這個漏(lou)抗(kang)上必(bi)然存(cun)在著(zhu)壓(ya)(ya)降(jiang)或(huo)(huo)容(rong)升,使試(shi)(shi)品上的(de)電(dian)(dian)(dian)壓(ya)(ya)低于(yu)或(huo)(huo)高(gao)于(yu)低壓(ya)(ya)側(ce)測量(liang)電(dian)(dian)(dian)壓(ya)(ya)表上反映出(chu)來的(de)電(dian)(dian)(dian)壓(ya)(ya)。工頻耐壓(ya)(ya)試(shi)(shi)驗(yan)時,被(bei)試(shi)(shi)品上的(de)電(dian)(dian)(dian)壓(ya)(ya)高(gao)于(yu)試(shi)(shi)驗(yan)變壓(ya)(ya)器的(de)輸出(chu)電(dian)(dian)(dian)壓(ya)(ya),也就是(shi)所(suo)謂(wei)容(rong)升現(xian)象(xiang)。感應(ying)耐壓(ya)(ya)試(shi)(shi)驗(yan)時,試(shi)(shi)驗(yan)變壓(ya)(ya)器的(de)漏(lou)抗(kang)必(bi)然存(cun)在著(zhu)壓(ya)(ya)降(jiang)。為了準確測量(liang)被(bei)試(shi)(shi)品上所(suo)施加(jia)的(de)電(dian)(dian)(dian)壓(ya)(ya),因此常在高(gao)壓(ya)(ya)側(ce)接入標準高(gao)壓(ya)(ya)分壓(ya)(ya)器來測量(liang)電(dian)(dian)(dian)壓(ya)(ya)。
六(liu)、操作(zuo)要點
1、試(shi)驗前(qian),應(ying)了解被試(shi)品(pin)的試(shi)驗電壓,同時(shi)了解被試(shi)品(pin)的其(qi)他試(shi)驗項目(mu)及以前(qian)的試(shi)驗結果。若被試(shi)品(pin)有(you)缺陷或(huo)異常,應(ying)在消(xiao)除后再進行耐壓試(shi)驗。
2、試驗現場(chang)應圍(wei)好(hao)遮攔(lan)或圍(wei)繩,掛(gua)好(hao)標示牌,并派專(zhuan)人(ren)監(jian)護。
3、試驗前,被試品(pin)表面(mian)應擦拭干(gan)凈,將(jiang)被試品(pin)的(de)(de)(de)外殼(ke)和非(fei)被試繞組(zu)可靠接地。被試品(pin)為新沖油(you)(you)設備時(shi)(shi),應按《規(gui)程》規(gui)定(ding)使(shi)油(you)(you)靜(jing)止(zhi)一(yi)定(ding)時(shi)(shi)間(jian)(jian)再(zai)升壓,對110kV及(ji)以下的(de)(de)(de)充油(you)(you)電(dian)力設備,在注滿油(you)(you)后靜(jing)置時(shi)(shi)間(jian)(jian)應不少于24小時(shi)(shi),對220kV及(ji)330kV的(de)(de)(de)充油(you)(you)電(dian)力設備,靜(jing)置時(shi)(shi)間(jian)(jian)應不少于48小時(shi)(shi)。
4、接好試驗接線(xian)后,應由有(you)經驗的人員檢查,確認無誤(wu)后方可升壓。
5、升壓(ya)前,首先檢查調壓(ya)器是否在零位(wei)。調壓(ya)器在零位(wei)方可升壓(ya)。
6、升壓(ya)過程中不(bu)(bu)僅要監視電壓(ya)的變化(hua)(hua),還應(ying)監視電流(liu)的變化(hua)(hua),以及被(bei)試品(pin)泄漏電流(liu)的變化(hua)(hua)。升壓(ya)時(shi)要均勻升壓(ya),不(bu)(bu)能太快(kuai)。升至(zhi)規定試驗電壓(ya)時(shi),開(kai)始計時(shi),時(shi)間(jian)到(dao)后,緩慢均勻降下(xia)電壓(ya)。絕不(bu)(bu)允許不(bu)(bu)降壓(ya)就先跳(tiao)開(kai)電源開(kai)關。
7、試驗中發(fa)現被試品(pin)(pin)有異常聲響、冒煙等應立(li)即降(jiang)下(xia)電壓,拉(la)開電源(yuan),在高壓側掛上(shang)接地線后(hou),再查明原因。耐壓試驗前(qian)后(hou)均應測量被試品(pin)(pin)的絕緣(yuan)電阻。
七、面(mian)板功能說明
打印機:打印機是熱敏打印機,當試驗(yan)完成后按鍵盤上的“打印”按鈕打印試驗(yan)結果(guo)。
RS232:RS232是與計算機相連的串(chuan)口(kou)(kou)通信(xin)接口(kou)(kou),是用(yong)戶選配接口(kou)(kou),本裝置(zhi)沒有配置(zhi)這個接口(kou)(kou)。
LCD對比度:因為液晶顯示屏(ping)在溫度和光(guang)線有所(suo)不(bu)同時稍有些變(bian)化,可以通(tong)過LCD對比度調(diao)節(jie)背(bei)光(guang)到適合亮(liang)度。
液晶: 320x240像(xiang)素(su)點陣白色背光液晶,在強光和陰暗環境下都十分清楚。
指示燈(deng):由啟動(dong)燈(deng)、零位燈(deng)、指示燈(deng)三個燈(deng)組成,啟動(dong)燈(deng)和警示燈(deng)是(shi)高亮七彩燈(deng)。
操(cao)作提(ti)示:有一些簡(jian)短的提(ti)示語句和安(an)裝接線圖。
緊急開(kai)關:在(zai)緊急情況下按(an)此開(kai)關,即可以切斷(duan)變壓器電源,也可以切斷(duan)工(gong)作電源。(箱式(shi)安(an)裝在(zai)面(mian)板上,臺式(shi)安(an)裝在(zai)柜體上)
鍵盤:由上(shang)、下、左(zuo)、右、設(she)置、打印(yin)、確定、取消8個鍵組(zu)成(cheng),是用(yong)戶和設(she)備(bei)交互的終端。
電(dian)源開關:工作電(dian)源,帶通(tong)電(dian)指示(shi)燈。
八、軟件(jian)使(shi)用說明
按試(shi)(shi)(shi)驗要求將控制部分、試(shi)(shi)(shi)驗變壓器(qi)、被試(shi)(shi)(shi)品正確(que)接好(hao)線,必須(xu)可靠接地(di),請參考圖(tu)(tu)(tu)1、圖(tu)(tu)(tu)2、圖(tu)(tu)(tu)3、圖(tu)(tu)(tu)4、圖(tu)(tu)(tu)5。
1、開機使用
開機處于(yu)“歡迎界面”,如(ru)圖7:
根(gen)據鍵盤(pan)的示圖8,按上↑、下↓、左(zuo)←,右→可以切換“自動(dong)耐(nai)壓(ya)(ya)試(shi)驗(yan)(yan)”或“手(shou)動(dong)耐(nai)壓(ya)(ya)試(shi)驗(yan)(yan)”,在“自動(dong)試(shi)驗(yan)(yan)”或“手(shou)動(dong)試(shi)驗(yan)(yan)”里面選擇“交流(liu)試(shi)驗(yan)(yan)方(fang)式”或“直流(liu)試(shi)驗(yan)(yan)方(fang)式”。如圖9
說明:
(1)當配置的(de)是交(jiao)直(zhi)(zhi)流(liu)兩用控制部分時(shi),使用直(zhi)(zhi)流(liu)輸出(chu)時(shi)軟件操(cao)作請(qing)進入直(zhi)(zhi)流(liu)試驗方式,交(jiao)流(liu)輸出(chu)時(shi)軟件操(cao)作請(qing)進入交(jiao)流(liu)試驗方式,如果(guo)選擇錯誤(wu)會導(dao)致儀(yi)器顯(xian)示電(dian)壓會和輸出(chu)實(shi)際電(dian)壓不一致。
(2)當配(pei)置的(de)是交直流(liu)兩用(yong)變(bian)壓器(qi)時(shi),使用(yong)直流(liu)時(shi)請將變(bian)壓器(qi)的(de)短路桿取出,當使用(yong)交流(liu)時(shi)請將短路桿插入擰緊。
(3)如果配置的是交(jiao)流控制部分時,軟件界面(mian)里就(jiu)沒有交(jiao)直流試驗方式(如圖9)的選擇項。
選中(zhong)試(shi)驗方式后,按(an)確(que)定(ding)可以進入(ru)主界面,如圖10:
動(dong)態(tai)顯示(shi)區:一直(zhi)處于采集信(xin)號,并顯示(shi)高(gao)(gao)壓(ya)電(dian)壓(ya)、高(gao)(gao)壓(ya)電(dian)流、低(di)(di)壓(ya)電(dian)壓(ya)、低(di)(di)壓(ya)電(dian)流。
結果(guo)(guo)顯示區:如果(guo)(guo)試(shi)驗(yan)沒有被擊穿時,顯示平(ping)均(jun)高壓(ya)(ya)(ya)電(dian)(dian)壓(ya)(ya)(ya),平(ping)均(jun)高壓(ya)(ya)(ya)電(dian)(dian)流(liu)(liu),平(ping)均(jun)低(di)壓(ya)(ya)(ya)電(dian)(dian)壓(ya)(ya)(ya),平(ping)均(jun)低(di)壓(ya)(ya)(ya)電(dian)(dian)流(liu)(liu),絕緣電(dian)(dian)阻;否(fou)之,顯示峰值電(dian)(dian)壓(ya)(ya)(ya),峰值電(dian)(dian)流(liu)(liu),低(di)壓(ya)(ya)(ya)電(dian)(dian)壓(ya)(ya)(ya),低(di)壓(ya)(ya)(ya)電(dian)(dian)流(liu)(liu)。
設(she)(she)置數據區:設(she)(she)置試驗中(zhong)需要的(de)(de)參數數據輸出(chu)電壓(ya)(ya)(ya)(ya)為(wei)(wei)在自動(dong)方式(shi)下的(de)(de)升壓(ya)(ya)(ya)(ya)目(mu)標耐(nai)壓(ya)(ya)(ya)(ya)值耐(nai)壓(ya)(ya)(ya)(ya)時間(jian)為(wei)(wei)耐(nai)壓(ya)(ya)(ya)(ya)過程的(de)(de)時間(jian)長度(du)電流(liu)上限(xian)為(wei)(wei)高壓(ya)(ya)(ya)(ya)電流(liu)峰(feng)值的(de)(de)上限(xian),高壓(ya)(ya)(ya)(ya)電流(liu)超過電流(liu)上限(xian)將(jiang)認為(wei)(wei)擊(ji)穿過流(liu)保護(hu)為(wei)(wei)低(di)壓(ya)(ya)(ya)(ya)電流(liu)峰(feng)值的(de)(de)上限(xian),低(di)壓(ya)(ya)(ya)(ya)電流(liu)超過過流(liu)保護(hu)將(jiang)認為(wei)(wei)擊(ji)穿
信息(xi)顯示(shi)區:顯示(shi)試(shi)驗過程(cheng)中的試(shi)驗狀態和提示(shi)信息(xi)。
試驗操(cao)作區(qu):選擇設置、試驗、回零命令。
2、設(she)置(zhi)參數
在主界面上,選(xuan)中“設置”,然后按確定(ding)后進入設置界面,如圖11:
按左←,右(you)→時(shi)切換光標(biao)(biao)移動位置,按上↑、下(xia)↓時(shi)更改光標(biao)(biao)位置數據的值(zhi)。光標(biao)(biao)位置和設(she)置的數值(zhi)全部可以自(zi)動循環,前且(qie)在使用時(shi)有默(mo)認的標(biao)(biao)準(zhun)值(zhi)。如果所(suo)有的參數都設(she)置完成,按取消退(tui)出設(she)置回(hui)到主界面(mian)開始(shi)狀態。
3、手動試驗
零(ling)位檢查(cha)—當(dang)選(xuan)中(zhong)“試(shi)(shi)驗(yan)”后,按確定就進入提示(shi)試(shi)(shi)驗(yan)狀態。如果調壓器不在零(ling)位,將提示(shi)“試(shi)(shi)驗(yan)前請先回零(ling)”,退出試(shi)(shi)驗(yan)并且切換到回零(ling)命令(ling)。
試驗(yan)(yan)過程(cheng)—回(hui)零(ling)確認后(hou),可(ke)以進行(xing)試驗(yan)(yan)。選中“試驗(yan)(yan)”后(hou)按確定,接(jie)觸器合閘,這時輸出電壓(ya)幾乎為(wei)0,如圖12:
按上↑,高壓(ya)電壓(ya)將(jiang)不斷升(sheng)壓(ya),松開就停止升(sheng)壓(ya),如果到上限就提示滿量(liang)程;
按下(xia)↓,高(gao)壓(ya)電壓(ya)將(jiang)不斷降(jiang)壓(ya),松(song)開就(jiu)停止降(jiang)壓(ya),如(ru)果到下(xia)限就(jiu)提示已回零(ling);
按計時(shi)←,計時(shi)開始工作,到耐壓時(shi)間(jian)計時(shi)結束(shu)完成試驗;
按(an)取消→,取消試驗過程;
在(zai)升壓(ya)(ya)過程中,如果高壓(ya)(ya)電(dian)(dian)流(liu)峰值(zhi)(zhi)(zhi)超(chao)過“電(dian)(dian)流(liu)上限”值(zhi)(zhi)(zhi)或低(di)壓(ya)(ya)電(dian)(dian)流(liu)峰值(zhi)(zhi)(zhi)超(chao)過“過流(liu)保護”值(zhi)(zhi)(zhi)將認(ren)為被(bei)(bei)試(shi)(shi)品(pin)被(bei)(bei)擊穿(chuan),接觸器(qi)(qi)立(li)刻分(fen)閘并顯示試(shi)(shi)驗結果,包(bao)括峰值(zhi)(zhi)(zhi)電(dian)(dian)壓(ya)(ya)、峰值(zhi)(zhi)(zhi)電(dian)(dian)流(liu)、低(di)壓(ya)(ya)電(dian)(dian)流(liu)等,調壓(ya)(ya)器(qi)(qi)開始回(hui)零,回(hui)零完成試(shi)(shi)驗結束。如果在(zai)耐(nai)壓(ya)(ya)過程中,高壓(ya)(ya)電(dian)(dian)流(liu)和(he)低(di)壓(ya)(ya)電(dian)(dian)流(liu)峰值(zhi)(zhi)(zhi)沒有超(chao)設置上限值(zhi)(zhi)(zhi),認(ren)為被(bei)(bei)試(shi)(shi)品(pin)未(wei)擊穿(chuan),結果顯示區(qu)就顯示耐(nai)壓(ya)(ya)電(dian)(dian)壓(ya)(ya)、高壓(ya)(ya)電(dian)(dian)流(liu)、低(di)壓(ya)(ya)電(dian)(dian)流(liu)、絕緣(yuan)電(dian)(dian)阻等,調壓(ya)(ya)器(qi)(qi)開始回(hui)零,回(hui)零完成后接觸器(qi)(qi)分(fen)閘試(shi)(shi)驗結束。
4、自(zi)動試驗(yan)
自動試(shi)(shi)驗和手動試(shi)(shi)驗的(de)試(shi)(shi)驗過程類似,首(shou)先也進行回零檢(jian)查(cha),確認后進入如下界(jie)面,如圖13:
按上方法切(qie)換到“開始”確定(ding)后進(jin)行(xing)試(shi)(shi)驗,與(yu)手動(dong)試(shi)(shi)驗不同之(zhi)處就是升(sheng)壓(ya)過(guo)程將自動(dong)升(sheng)壓(ya)到“輸出電壓(ya)”值,然后進(jin)行(xing)計時。
升壓過程為(wei)(wei)逼近方式,首(shou)先升到(dao)到(dao)接近目標值,然后再進行微調,保證高壓電壓值幾乎為(wei)(wei)輸出電壓值。
5、功(gong)能選擇
按(an)鍵盤(pan)上(shang)的“設置”就(jiu)進入功能(neng)界(jie)面,如圖14:
進入功能界面后,可(ke)以選擇“時鐘設置(zhi)”、“注(zhu)意事項”等(deng)界面。
時(shi)鐘設置:設置時(shi)鐘的時(shi)間(jian),為打(da)印報表提供時(shi)間(jian)依據(ju)。
注意(yi)事(shi)項(xiang):為(wei)用戶提供一些操作(zuo)規范和**注意(yi)事(shi)項(xiang)。
6、打印
按鍵盤“打(da)印(yin)”按鍵可(ke)以打(da)印(yin)試驗果,在(zai)此(ci)不贅述。
七、產品維護
1、開箱驗收(shou)時,應檢查主控回路接線(xian)是否松動,調壓(ya)器電刷是否接觸(chu)良好。
2.、長(chang)期不用(yong)時,使用(yong)前(qian)應用(yong)500V兆歐表測量絕(jue)緣電阻,其阻值不低于0.5MΩ。
3、電源電壓應符合控制箱(臺)說明書上(shang)的輸(shu)入電壓值(zhi)要(yao)求。
4、本控制(zhi)箱(臺(tai))設有過電流保(bao)護(hu),出(chu)廠已調整為額定電流的50%。用于小負載(zai)時,應根據被試品的額定容量電流重(zhong)新設定;
5、使用(yong)完畢后,應關好控制箱(xiang)(臺)門蓋,以保持(chi)內部清潔。
八(ba)、注(zhu)意(yi)事項(xiang)
1、按照您所進(jin)行(xing)的試(shi)驗接(jie)好工作(zuo)(zuo)線路(lu)。試(shi)驗變壓(ya)器(qi)的外殼以及操(cao)作(zuo)(zuo)系統的外殼必(bi)須可靠接(jie)地。試(shi)驗變壓(ya)器(qi)的測量繞組的F端和外殼必(bi)須可靠接(jie)地。
2、做串級(ji)試(shi)驗(yan)時,**級(ji)、第三(san)(san)級(ji)試(shi)驗(yan)變壓器(qi)的低壓繞組(zu)成(cheng)X端(duan),測量繞組(zu)的F端(duan)以(yi)及高壓繞組(zu)的X端(duan)(高壓端(duan))均接本級(ji)試(shi)驗(yan)變壓器(qi)具外(wai)(wai)殼。**級(ji)、第三(san)(san)級(ji)試(shi)驗(yan)變壓器(qi)的外(wai)(wai)殼必須(xu)通過絕緣支架接地。
接(jie)(jie)通電源前,控(kong)制箱(臺)的調壓器必須調到(dao)零位(wei)后方可接(jie)(jie)通電源,合(he)閘(zha),開(kai)始(shi)升(sheng)壓。
3、從零開始(shi)勻(yun)速(su)(su)(su)旋轉調壓(ya)(ya)(ya)器(qi)手輪(lun)升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)。升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)方(fang)式有:快速(su)(su)(su)升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)法(fa),即20s逐(zhu)級(ji)升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)法(fa);慢速(su)(su)(su)升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)法(fa),即60s逐(zhu)級(ji)升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)法(fa);極慢速(su)(su)(su)升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)法(fa)供選用。電(dian)壓(ya)(ya)(ya)從零開始(shi)按一定的(de)(de)升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)方(fang)式和速(su)(su)(su)度上升(sheng)(sheng)(sheng)(sheng)到(dao)您(nin)(nin)所需的(de)(de)額(e)定試(shi)(shi)(shi)(shi)驗(yan)電(dian)壓(ya)(ya)(ya)的(de)(de)75%后(hou),再以每秒2%額(e)定試(shi)(shi)(shi)(shi)驗(yan)電(dian)壓(ya)(ya)(ya)的(de)(de)速(su)(su)(su)度升(sheng)(sheng)(sheng)(sheng)到(dao)您(nin)(nin)所需的(de)(de)試(shi)(shi)(shi)(shi)驗(yan)電(dian)壓(ya)(ya)(ya),并(bing)密切注意(yi)測量儀(yi)表的(de)(de)及(ji)(ji)被試(shi)(shi)(shi)(shi)品的(de)(de)情況。升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)過(guo)程(cheng)中(zhong)或試(shi)(shi)(shi)(shi)驗(yan)過(guo)程(cheng)中(zhong)如發現測量儀(yi)表的(de)(de)指示及(ji)(ji)被試(shi)(shi)(shi)(shi)品情況異常,應(ying)立即降(jiang)壓(ya)(ya)(ya),切斷電(dian)源,查(cha)明情況。
4、試驗完畢(bi)后(hou),應(ying)在等調壓器返回至零位,然后(hou)切斷電(dian)源。
5、本(ben)產品不(bu)得(de)超過額定(ding)參(can)數使(shi)用。
6、使(shi)用(yong)本(ben)產品做高壓試(shi)驗時,除熟悉本(ben)說明書外,還必須嚴格執行國家有關(guan)標準(zhun)和操作規程(cheng)。可(ke)參照GB311.1 – 97《高壓輸(shu)變設(she)備的絕(jue)緣配合(he),高壓試(shi)驗技(ji)術》;《電氣設(she)備預防(fang)性試(shi)驗規程(cheng)》等。
7、控(kong)制箱(臺(tai))應(ying)與試驗變壓器配(pei)套使用,控(kong)制箱(臺(tai))的使用方法,請詳(xiang)細參閱(yue)控(kong)制器的使用說明書。