一、WBYD2000變頻串并聯諧振耐壓試驗機基本原理
耐壓(ya)(ya)(ya)試(shi)驗是(shi)利用電(dian)(dian)抗器的電(dian)(dian)感與被(bei)試(shi)品(pin)電(dian)(dian)容組(zu)成LC串聯回路,調節變頻(pin)電(dian)(dian)源輸出的電(dian)(dian)壓(ya)(ya)(ya)頻(pin)率(lv),在被(bei)試(shi)品(pin)上獲得(de)高電(dian)(dian)壓(ya)(ya)(ya),是(shi)當前高電(dian)(dian)壓(ya)(ya)(ya)試(shi)驗的一(yi)種新(xin)方法,深受(shou)專(zhuan)家(jia)好評,在國內外已經得(de)到廣泛(fan)的使(shi)用。
根據諧振(zhen)原理,我們知道當電(dian)(dian)抗(kang)器(qi)(qi)L的感抗(kang)值Xl與回(hui)(hui)(hui)路(lu)中的容(rong)抗(kang)值Xc相等時(shi),回(hui)(hui)(hui)路(lu)達到(dao)諧振(zhen)狀(zhuang)態(tai),此時(shi)回(hui)(hui)(hui)路(lu)中僅(jin)回(hui)(hui)(hui)路(lu)電(dian)(dian)阻R消耗有功(gong)(gong)功(gong)(gong)率,而無功(gong)(gong)功(gong)(gong)率則(ze)在電(dian)(dian)抗(kang)器(qi)(qi)與試(shi)品電(dian)(dian)容(rong)之(zhi)間來(lai)回(hui)(hui)(hui)振(zhen)蕩(dang),從而在試(shi)品上產生高壓。
二、WBYD2000變頻串并聯諧振耐壓試驗機系統構成
全套試驗(yan)系(xi)統(tong)由調頻(pin)電(dian)源主機、電(dian)抗器(qi)(qi)、分壓器(qi)(qi)、激勵變壓器(qi)(qi)和補償(chang)電(dian)容(rong)器(qi)(qi)(可選器(qi)(qi)件(jian))組(zu)成(cheng),接(jie)入被試品(pin)后組(zu)成(cheng)一個(ge)諧振(zhen)系(xi)統(tong)進行交流耐壓實驗(yan)。
主(zhu)機: 就是一臺幅值和頻(pin)率可調的正弦波交流調頻(pin)電源(yuan),給(gei)諧振回路提(ti)供激勵源(yuan),同(tong)時提(ti)供電壓顯示、電流顯示、計(ji)時、保(bao)護、報(bao)警(jing)等功能。
電(dian)(dian)(dian)抗器(qi)(qi)(qi):就(jiu)是(shi)一個大電(dian)(dian)(dian)感(gan)線圈(quan),與(yu)被試品(相當于電(dian)(dian)(dian)容)構成(cheng)回路(lu),可配置電(dian)(dian)(dian)抗器(qi)(qi)(qi)多節電(dian)(dian)(dian)抗器(qi)(qi)(qi),使用時通過不(bu)同的串聯(lian)、并聯(lian)組(zu)合、實(shi)現不(bu)同的電(dian)(dian)(dian)感(gan)量(liang)以適用不(bu)同的試驗條件。
分(fen)壓(ya)器(qi):內部通過電容器(qi)分(fen)壓(ya),從(cong)試品(pin)上高電壓(ya)分(fen)得低電壓(ya)供主機測(ce)量、控制使用。
勵磁變(bian)壓器:隔離主機電源(yuan)與諧振回路電源(yuan),并升高主機的輸(shu)出電壓。
補償電(dian)(dian)容(rong)(rong)器(qi)(qi):當試(shi)品(pin)電(dian)(dian)容(rong)(rong)量(liang)很小時,如果要實現系統(tong)諧振可能要求的電(dian)(dian)源頻(pin)率(lv)超出試(shi)驗(yan)標準的規(gui)定(ding),可在試(shi)品(pin)上(shang)并聯一個補償電(dian)(dian)容(rong)(rong),以實現試(shi)驗(yan)要求,稱此(ci)電(dian)(dian)容(rong)(rong)器(qi)(qi)為補償電(dian)(dian)容(rong)(rong)器(qi)(qi)。
三、WBYD2000變頻串并聯諧振耐壓試驗機主要技術性能
功率電源電壓:AC380V±10%、50Hz;
儀器電源:220V±10%、50Hz;
諧(xie)振輸出(chu)容(rong)量:200kVA;
儀器額定電壓:0~200kV;
輸出(chu)頻率范圍(wei):30~300Hz;
輸出電壓波(bo)形(xing)(xing):正弦波(bo),波(bo)形(xing)(xing)畸變率<0.5%;
頻(pin)率調節(jie)靈敏度(du):0.1Hz,不穩(wen)定度(du)≤0.05%;
系統噪聲:≤60db;
9、系統(tong)測量精度:<1級;
10.輸(shu)出電壓不穩(wen)定(ding):<0.5%;
11.保護響應(ying)時間:1us;
12.電感(gan)非線性度(du):≤0.05%;;
13.滿功率輸出下(xia),連續工作時間(jian)為60min
14.環(huan)境(jing)溫度:-15℃~+50℃;
15.相對濕度(du):≤90%RH;
16.海拔高度(du):≤2000米。
四、WBYD2000變頻串并聯諧振耐壓試驗機面板及部件名稱
五、WBYD2000變頻串并聯諧振耐壓試驗機操作步驟
1、正確連線,檢查無誤后方可送電。
必要時工作電源的跳過現(xian)場漏(lou)電保安器,以免(mian)不必要的跳閘(zha)。
2、打開(kai)電(dian)源開(kai)關,主機開(kai)始工作,液晶屏顯示版權頁(ye),該(gai)頁(ye)標(biao)明本裝置的軟件版本號。
觸按(an)確認(ren)鍵(jian),進入(ru)系統(tong)菜(cai)(cai)單,該主菜(cai)(cai)單下(xia)有:試驗(yan)方案(an)、開始試驗(yan)、試驗(yan)幫(bang)助(zhu)、系統(tong)設置、實用工具(ju)和試驗(yan)記錄等六個子菜(cai)(cai)單項。
3、 系(xi)(xi)統(tong)(tong)設(she)置(zhi)(zhi)(zhi)菜(cai)單(dan)(dan)下(xia)有電抗(kang)器電感(gan)、日期(qi)時間設(she)置(zhi)(zhi)(zhi)和(he)采(cai)樣系(xi)(xi)數設(she)置(zhi)(zhi)(zhi)等三個子(zi)菜(cai)單(dan)(dan)項。按(an)上下(xia)鍵,上下(xia)移(yi)動光(guang)標系(xi)(xi)統(tong)(tong)參數設(she)置(zhi)(zhi)(zhi)菜(cai)單(dan)(dan)項,觸按(an)確定鈕后,進(jin)入系(xi)(xi)統(tong)(tong)參數設(she)置(zhi)(zhi)(zhi)菜(cai)單(dan)(dan),可以分(fen)別設(she)定電抗(kang)器的電感(gan)—H、-年-月-日、-時-分(fen)-秒和(he)電壓和(he)電流的采(cai)樣系(xi)(xi)數也就(jiu)是采(cai)樣倍率,設(she)定完(wan)成后,觸按(an)返還鍵返回(hui)上**菜(cai)單(dan)(dan)。
電抗(kang)器電感量(liang)的(de)(de)設(she)定:按(an)確(que)定鍵(jian)(jian)選擇到此項,按(an)左右鍵(jian)(jian)移動(dong)光標需要改變的(de)(de)數位,按(an)上下(xia)鍵(jian)(jian)改變數值(zhi),達(da)到所要達(da)到的(de)(de)數值(zhi)按(an)確(que)定鍵(jian)(jian)確(que)認。
日期時間的(de)設(she)定(ding):按(an)確(que)定(ding)鍵選擇到此(ci)項,按(an)左(zuo)右鍵移動光(guang)標(biao)需要(yao)改變(bian)的(de)數(shu)位,按(an)上下鍵改變(bian)數(shu)值(zhi),按(an)照所要(yao)設(she)置(zhi)的(de)年月日時間數(shu)值(zhi)按(an)確(que)定(ding)鍵確(que)認。
采(cai)樣(yang)系數的設(she)定(ding)(ding)(ding):按確定(ding)(ding)(ding)鍵選擇(ze)到(dao)高(gao)壓/電(dian)流采(cai)樣(yang)系數項,此項為電(dian)壓或電(dian)流采(cai)樣(yang)倍(bei)率的設(she)定(ding)(ding)(ding)。一般(ban)出廠前設(she)定(ding)(ding)(ding)好了。如需修改,要輸入密碼(ma)。(密碼(ma)廠家與設(she)備(bei)一起提供一般(ban)設(she)定(ding)(ding)(ding)為:188888)
警告:系統(tong)默認上一(yi)次電(dian)抗器(qi)(qi)電(dian)感、日期時間(jian)和采樣系數設定值。如果需改變要(yao)重新設定。電(dian)抗器(qi)(qi)電(dian)感量(liang)設定值與實際使(shi)用(yong)的電(dian)抗器(qi)(qi)電(dian)感量(liang)不(bu)對,會(hui)導致試驗報告中的被試品(pin)電(dian)容量(liang)不(bu)準(zhun)。其他并不(bu)會(hui)影響。采樣系數設置不(bu)正(zheng)確,會(hui)導致顯(xian)示電(dian)壓電(dian)流不(bu)準(zhun)將很有可能會(hui)對被試品(pin)或試驗設備造成損(sun)壞。
4、試驗(yan)方(fang)案菜單下有(you)預(yu)置保護電流(liu)、找(zhao)頻起始(shi)頻率(lv)(lv)、找(zhao)頻結束(shu)(shu)頻率(lv)(lv)、預(yu)定起始(shi)功(gong)率(lv)(lv)四個子菜單項,分別設定本次試驗(yan)的保護電流(liu)、找(zhao)頻起始(shi)頻率(lv)(lv)、找(zhao)頻結束(shu)(shu)頻率(lv)(lv)、輸出起始(shi)功(gong)率(lv)(lv),全部(bu)設定完成后,觸按返還鍵進入預(yu)置試驗(yan)電壓和預(yu)置試驗(yan)時(shi)間(jian)設置菜單。
可以(yi)分(fen)3段時間設置試驗(yan)電壓(ya)和試驗(yan)時間, 實(shi)際試驗(yan)時,若設定(ding)為自動(dong)試驗(yan), 裝(zhuang)置將按(an)設定(ding)的3段電壓(ya)及(ji)時間,按(an)順序分(fen)別加壓(ya), 全部完成后自動(dong)退出.
如果**段電壓(ya)設為0, 或時間設為0, 那么(me)執行完**段試(shi)(shi)驗電壓(ya)加壓(ya)后退出試(shi)(shi)驗, 只加壓(ya)**段設定的電壓(ya).
如(ru)果第三(san)段電壓設為0, 或時(shi)間(jian)設為0, 不執行第三(san)段加壓.
試驗(yan)方(fang)案設(she)置的(de)設(she)定:在(zai)試驗(yan)電壓(ya)項中,按(an)確定單鈕,移動左右光標到需要改變的(de)數(shu)(shu)位,按(an)上下單鈕以改變當前(qian)數(shu)(shu)位的(de)數(shu)(shu)值(zhi)大小,觸按(an)返回鈕完成當前(qian)數(shu)(shu)位的(de)數(shu)(shu)值(zhi)設(she)定,依次(ci)選(xuan)擇下一項數(shu)(shu)值(zhi)的(de)設(she)定,直至分別(bie)完成試驗(yan)時間、起(qi)始頻(pin)率(lv)、起(qi)始功率(lv)的(de)設(she)置,方(fang)可(ke)完成本(ben)次(ci)試驗(yan)的(de)試驗(yan)方(fang)案設(she)置的(de)設(she)定。
出(chu)廠默認值(zhi):試(shi)驗電(dian)壓 20kV、加壓時間 2min、激勵強度 2%、輸出(chu)電(dian)流(liu)20A、頻(pin)率范圍30-300Hz。
5、實用工具(ju)菜(cai)單(dan)下有
頻率(lv)(lv)計算(suan):在實驗(yan)前可對諧振頻率(lv)(lv)進行計算(suan)。只需輸入具(ju)體參與試驗(yan)的電感、電容值并按確定鍵試驗(yan)頻率(lv)(lv)即直(zhi)接生(sheng)成。
6、開始試(shi)驗(yan)菜(cai)單(dan)下(xia)有(you)自動(dong)試(shi)驗(yan)模式和手動(dong)試(shi)驗(yan)模式兩種子菜(cai)單(dan)可供選(xuan)擇(ze)。
按確認鍵進入所(suo)選(xuan)試驗步驟.
自動試驗模式(shi)(shi)的(de)操作:選中自動試驗模式(shi)(shi)后,觸按菜(cai)單鈕進入正在(zai)(zai)自動尋(xun)找(zhao)諧振(zhen)(zhen)點菜(cai)單項,裝(zhuang)置在(zai)(zai)設(she)定的(de)頻(pin)率(lv)范圍(wei)(wei)內自動尋(xun)找(zhao)諧振(zhen)(zhen)點(如(ru)果被試品電容C和電抗(kang)器(qi)電感(gan)L的(de)實(shi)際諧振(zhen)(zhen)頻(pin)率(lv)不在(zai)(zai)設(she)定的(de)頻(pin)率(lv)范圍(wei)(wei)內,將(jiang)找(zhao)不到(dao)諧振(zhen)(zhen)點,此時(shi)根據需要調(diao)整頻(pin)率(lv)范圍(wei)(wei)或(huo)調(diao)整被試品回路的(de)LC參(can)數(shu))。當找(zhao)到(dao)諧振(zhen)(zhen)點時(shi),會有聲音提示。
找(zhao)到(dao)諧振點后,裝(zhuang)(zhuang)置自(zi)動(dong)進入正在自(zi)動(dong)升壓(ya)(ya)菜單項,當升到(dao)試驗電壓(ya)(ya)設(she)定的電壓(ya)(ya)時,裝(zhuang)(zhuang)置停止加(jia)壓(ya)(ya)。
當裝置升到(dao)試驗(yan)(yan)電壓(ya)設(she)(she)定的(de)(de)電壓(ya)時,設(she)(she)備(bei)停(ting)止加(jia)壓(ya),自動進入(ru)正在加(jia)壓(ya)試驗(yan)(yan)菜(cai)單項,并自動記錄試驗(yan)(yan)的(de)(de)加(jia)壓(ya)時間,當加(jia)壓(ya)時間到(dao)達設(she)(she)定時間時,設(she)(she)備(bei)逐(zhu)步降壓(ya)退出試驗(yan)(yan),完成本(ben)次試驗(yan)(yan),進入(ru)試驗(yan)(yan)結束(shu)菜(cai)單項。并可選擇保存試驗(yan)(yan)數據(ju)或(huo)打印試驗(yan)(yan)數據(ju)。
試驗時間的一行顯(xian)示(shi)末(mo)端,會顯(xian)示(shi)[一段(duan)]或(huo)[二段(duan)]或(huo)[三段(duan)]字樣,表示(shi)當前正在進行的加(jia)壓試驗是預置的一段(duan),二段(duan)或(huo)三段(duan).
手(shou)動(dong)試驗(yan)(yan)模式的(de)(de)操作:選中手(shou)動(dong)試驗(yan)(yan)模式后觸按(an)確(que)定鈕(niu),進入(ru)正在(zai)試驗(yan)(yan)菜單項(xiang);手(shou)動(dong)按(an)調(diao)頻(pin)鈕(niu),對(dui)應的(de)(de)光(guang)標隨(sui)之改(gai)變到輸出頻(pin)率(lv)(lv)項(xiang),可(ke)以通過上下(xia)(xia)左右鍵改(gai)變頻(pin)率(lv)(lv)大小使其試驗(yan)(yan)電壓(ya)逐(zhu)(zhu)步升高(gao)(gao),當升到*高(gao)(gao)電壓(ya)時,繼續向上或向下(xia)(xia)調(diao)整(zheng)頻(pin)率(lv)(lv)按(an)鈕(niu),直至試驗(yan)(yan)電壓(ya)開始下(xia)(xia)降;這時反調(diao)頻(pin)率(lv)(lv),試驗(yan)(yan)電壓(ya)又(you)逐(zhu)(zhu)步回升,上下(xia)(xia)回調(diao)頻(pin)率(lv)(lv),從頻(pin)率(lv)(lv)的(de)(de)高(gao)(gao)位(wei)到低位(wei)逐(zhu)(zhu)位(wei)調(diao)整(zheng)*高(gao)(gao)電壓(ya)值時的(de)(de)頻(pin)率(lv)(lv)就是當前(qian)的(de)(de)諧振(zhen)頻(pin)率(lv)(lv)。
找到(dao)(dao)諧振點后,手(shou)動按(an)電壓(ya)(ya)鈕(niu),光(guang)標到(dao)(dao)了輸(shu)出(chu)功率,隨之按(an)上(shang)下鍵增加(jia)輸(shu)出(chu)功率,試(shi)驗(yan)電壓(ya)(ya)也(ye)逐步升(sheng)高,當(dang)升(sheng)到(dao)(dao)試(shi)驗(yan)電壓(ya)(ya)設定電壓(ya)(ya)值(zhi)時(shi)(shi),裝置停(ting)止加(jia)壓(ya)(ya),并有屏幕顯示提示和聲音提示;自動進入正在加(jia)壓(ya)(ya)試(shi)驗(yan)菜單(dan)項,并自動記錄試(shi)驗(yan)的加(jia)壓(ya)(ya)時(shi)(shi)間,當(dang)到(dao)(dao)達加(jia)壓(ya)(ya)時(shi)(shi)間設定時(shi)(shi)間時(shi)(shi),設備逐步降(jiang)壓(ya)(ya)退出(chu)試(shi)驗(yan),完成(cheng)本次試(shi)驗(yan),進入試(shi)驗(yan)結束菜單(dan)項。
注意:在(zai)調(diao)(diao)(diao)(diao)(diao)節頻(pin)(pin)率調(diao)(diao)(diao)(diao)(diao)整鈕(niu)(niu)的(de)(de)(de)過程中(zhong),觸按左(zuo)右(you)鈕(niu)(niu),可(ke)以改變頻(pin)(pin)率調(diao)(diao)(diao)(diao)(diao)節的(de)(de)(de)速(su)度實現(xian)(xian)粗細調(diao)(diao)(diao)(diao)(diao)的(de)(de)(de)切(qie)(qie)換。在(zai)調(diao)(diao)(diao)(diao)(diao)節電壓(ya)(ya)調(diao)(diao)(diao)(diao)(diao)整鈕(niu)(niu)的(de)(de)(de)過程中(zhong),向下觸按左(zuo)右(you)鈕(niu)(niu),可(ke)以改變電壓(ya)(ya)的(de)(de)(de)升(sheng)降的(de)(de)(de)速(su)度實現(xian)(xian)粗細調(diao)(diao)(diao)(diao)(diao)的(de)(de)(de)切(qie)(qie)換。觸按調(diao)(diao)(diao)(diao)(diao)頻(pin)(pin)、調(diao)(diao)(diao)(diao)(diao)壓(ya)(ya)鈕(niu)(niu),實現(xian)(xian)調(diao)(diao)(diao)(diao)(diao)頻(pin)(pin)與(yu)調(diao)(diao)(diao)(diao)(diao)壓(ya)(ya)間的(de)(de)(de)切(qie)(qie)換。
7、進入試(shi)驗記(ji)錄查(cha)詢菜單項,查(cha)詢以往和當前(qian)試(shi)驗數據。選(xuan)(xuan)擇(ze)上下鍵翻看(kan)前(qian)一組數據后一組數據;選(xuan)(xuan)擇(ze)左(zuo)右鍵可選(xuan)(xuan)擇(ze)打印或刪除當前(qian)頁的內容(rong)。
125/456為試(shi)驗(yan)數(shu)據(ju)庫(ku)(ku)指針,分子(zi)是試(shi)驗(yan)數(shu)據(ju)的在數(shu)據(ju)庫(ku)(ku)的順序數(shu),分母是當前的數(shu)據(ju)總數(shu),*多可儲存999組試(shi)驗(yan)數(shu)據(ju)。
8、裝置(zhi)和試(shi)(shi)驗狀態菜單提示(shi):設(she)備(bei)的(de)使用和升(sheng)壓和耐壓試(shi)(shi)驗過(guo)程中,如果(guo)出現影(ying)響(xiang)試(shi)(shi)驗設(she)備(bei)、被試(shi)(shi)驗設(she)備(bei)以及操作人的(de)**情況,設(she)備(bei)可能出現自動保護轉臺,并(bing)在屏幕有相應的(de)提示(shi)。
不(bu)能諧振(zhen):如果諧振(zhen)點不(bu)在諧振(zhen)頻率設置(zhi)的(de)范圍內;系統連線不(bu)正確(que)等現象,裝置(zhi)將找不(bu)到諧振(zhen)點,這時裝置(zhi)和試驗狀態(tai)菜單(dan)中的(de)不(bu)能諧振(zhen)項(xiang)被反白并閃(shan)爍。
輸出(chu)保(bao)(bao)護:如果裝(zhuang)置的(de)電源輸出(chu)電流大于輸出(chu)保(bao)(bao)護設定(ding)的(de)電流值,裝(zhuang)置自動保(bao)(bao)護,這時裝(zhuang)置和試(shi)驗(yan)狀態(tai)菜單中的(de)輸出(chu)保(bao)(bao)護項(xiang)被反(fan)白并(bing)閃爍。
試(shi)驗中(zhong)止:如果在試(shi)驗升壓(ya)或加壓(ya)過程出(chu)現(xian)閃絡現(xian)象,裝置(zhi)(zhi)自動保護(hu),這時(shi)裝置(zhi)(zhi)和(he)試(shi)驗狀(zhuang)態菜單(dan)中(zhong)的輸出(chu)保護(hu)項被(bei)反白并閃爍。
9、試驗幫(bang)助內容包括五(wu)大項(xiang)分別為:1.版本信息2.接線(xian)示(shi)意3.使用說明4.常(chang)見問(wen)(wen)題5.參考資料.如常(chang)見問(wen)(wen)題FAQ分五(wu)幅畫面(mian)顯示(shi)、各種被試品電(dian)力電(dian)纜、變壓器(qi)、發電(dian)機電(dian)容參數的(de)查詢:
接線示意圖:
10、設(she)(she)(she)備(bei)出(chu)廠(chang)參(can)(can)數設(she)(she)(she)置是生(sheng)產(chan)廠(chang)家的出(chu)廠(chang)設(she)(she)(she)置參(can)(can)術和(he)校驗(yan)參(can)(can)數,不適當的設(she)(she)(she)置和(he)修改會影響設(she)(she)(she)備(bei)性(xing)能和(he)高壓試驗(yan)的**性(xing),未經廠(chang)家授權(quan)密碼,無(wu)法(fa)修改。
警告(gao):正(zheng)常試(shi)(shi)驗(yan)狀態下(xia),按返回鍵即可中(zhong)止(zhi)試(shi)(shi)驗(yan)。中(zhong)止(zhi)或結束試(shi)(shi)驗(yan)后,應分離刀閘(zha)切(qie)斷電源。在升壓(ya)或加壓(ya)過(guo)程中(zhong),非緊急情(qing)況,不要按下(xia)急停(ting)鍵。
六、本(ben)說明書(shu)的專(zhuan)屬名詞的定義
自(zi)動試(shi)驗:高壓(ya)試(shi)驗全過程由主(zhu)機按程序和預置參(can)數自(zi)動完成。
自動調諧:調諧由主(zhu)機按程序自動完(wan)成,升壓手動完(wan)成。
手(shou)動(dong)試驗:尋(xun)找諧振點和(he)升(sheng)壓均為手(shou)動(dong),通過(guo)面板旋鈕(niu)完成。
系統參數設置是指對設備(bei)部件參數的設置。
試(shi)驗(yan)參數(shu)(shu)設(she)置是指對試(shi)驗(yan)過程參數(shu)(shu)的設(she)置。
試驗(yan)(yan)模式選擇(ze)是指對(dui)試驗(yan)(yan)模式的選擇(ze)。
試驗結果查(cha)詢是指對試驗數據的查(cha)詢。
分(fen)壓器變比是指對分(fen)壓器的分(fen)壓比設置。
電(dian)抗器(qi)電(dian)感是指對(dui)電(dian)抗器(qi)電(dian)抗值(zhi)的(de)設置。
激(ji)勵變變比是(shi)指對(dui)勵磁變壓器的變比設置(zhi)。
設置(zhi)電壓(ya)是高(gao)壓(ya)試驗(yan)時的(de)保護(hu)電壓(ya)設置(zhi)。
試驗(yan)(yan)電壓(ya)是高壓(ya)試驗(yan)(yan)時的試驗(yan)(yan)電壓(ya)。
加(jia)壓(ya)時間(jian)是施加(jia)試驗電壓(ya)的時間(jian)。
激勵強(qiang)度是指主機電源(yuan)輸(shu)出(chu)的大小。
輸出電(dian)(dian)流是主機電(dian)(dian)源的輸出電(dian)(dian)流。
頻(pin)率(lv)范圍是試驗的頻(pin)率(lv)范圍。
自動試驗模式是(shi)指試驗過程全部(bu)自動完成(cheng)。
自動調(diao)諧模式(shi)是指自動尋找諧振點后(hou),手(shou)動加壓(ya)完成(cheng)試(shi)驗(yan)。
手動試(shi)驗模式全部由人工完(wan)成(cheng)試(shi)驗過程。
未接(jie)地線主機電源(yuan)為(wei)接(jie)地。
不(bu)能諧振未能找(zhao)到諧振點。
輸(shu)出保護主機電(dian)源輸(shu)出電(dian)流大于整定電(dian)流。
試驗中止指在升壓或加(jia)壓過(guo)程裝置自動保護(hu)。
設備出(chu)廠參(can)數設置是廠家(jia)對設備有關參(can)數的(de)設置。
確(que)認鍵:確(que)認當(dang)前操作(zuo)。
返(fan)回(hui)鍵(jian):返(fan)回(hui)上**菜單。
七、變頻電源(yuan)技術參(can)數:
1.額定輸出容量:15kvA;
2.儀器電源:220v±10% 50Hz;
功率(lv)電源(yuan):380v±10% 50Hz;
3.額定輸入電流:39.5A;
4.額定輸出電壓:0-340v可調、單相、輸出電壓不穩定度0.05%;
5.額定輸出電流:44A;
6.頻率調(diao)節范圍:25~320Hz;
7.額定容(rong)量下(xia)連續運行為規(gui)定工(gong)作(zuo)時(shi)間下(xia)*高溫升(sheng)≤60K;
8.顯示以下(xia)參數(shu):
a.經變頻輸出的頻率、電(dian)壓、電(dian)流;
b.過壓(ya)保(bao)護(hu)(hu)電(dian)壓(ya)值,并(bing)可(ke)任(ren)意整(zheng)(zheng)定,當(dang)成套(tao)(tao)裝置(zhi)的(de)輸出(chu)電(dian)壓(ya)值達(da)到保(bao)護(hu)(hu)整(zheng)(zheng)定時,可(ke)自動切除成套(tao)(tao)裝置(zhi);
c.過流(liu)保(bao)護(hu)(hu):當調(diao)頻電源的輸出電流(liu)達(da)到保(bao)護(hu)(hu)整定值時,可自動(dong)切除成套(tao)裝置;
d.擊(ji)穿保(bao)護:當高壓側發生對地閃(shan)絡時(shi),可自動切除成套裝(zhuang)置,裝(zhuang)置帶有隔(ge)離裝(zhuang)置,可確保(bao)設備和人身(shen)不受(shou)損害;
e.具有全電壓(ya)輸出保護,在調(diao)壓(ya)過程中,一旦(dan)調(diao)壓(ya)失控,調(diao)頻電源立即閉鎖;
9.可(ke)實現以下(xia)操(cao)作:
a.頻(pin)率的調(diao)節,上升和(he)下降頻(pin)率調(diao)節分粗(cu)調(diao)和(he)細調(diao)兩種,并可自動尋(xun)找試(shi)驗諧振點,保證諧振頻(pin)率在整個試(shi)驗過程(cheng)中(zhong)不(bu)發生漂移;
b.帶有設置電(dian)壓(ya)、設置時(shi)間,電(dian)壓(ya)自(zi)動上升(sheng)到設置值而停止(zhi)并自(zi)動計時(shi);
c.帶(dai)有各種保護功能的整(zheng)定按鈕,可(ke)在(zai)面板上對各種保護值(zhi)進(jin)行整(zheng)定;
d.帶有手動試驗功能(neng)和自動試驗功能(neng);
e.帶(dai)有試驗數據打印功能。
八(ba)、勵磁變壓器技(ji)術參數:
1.結構形式(shi):干(gan)式(shi);
2.額定容量:15kVA;
3.輸(shu)入電壓:0~340V;
4.輸出電壓:四組并聯3.75KV;四組串(chuan)聯15KV;二串(chuan)二并7.5KV;
5.輸出電(dian)流:四組(zu)并聯4A;四組(zu)串聯1A;二串二并2A;
6.工(gong)作頻率范圍:30~300Hz;
勵磁變壓器的(de)接線(xian)端子,如(ru)圖所示(shi):
1.輸出(chu)端尾—與接地端連接。
2.輸出端頭—與(yu)電抗器(qi)連接(jie)。
3.接地(di)端—與(yu)變頻電源(yuan)、分壓器及被(bei)試品共同接地(di)。
4.輸(shu)入(ru)端(duan)—接調頻電源功率輸(shu)出端(duan)。
九、諧振電抗器技術參數(shu):
額定容(rong)量:55KVA;
額定電壓(ya):55kV;
額定電流:1.5A;
電 感 量:160H;
品(pin)質因數:Q≥30
采用環(huan)氧干式。
7.接線端了如圖所(suo)示:
a.高壓側接(jie)線端(duan)子(zi)—與被(bei)試品高壓端(duan)連接(jie)。
b.低壓側(ce)接線端子—與勵磁變輸(shu)出端連接。
c.多臺(tai)電抗器(qi)串(chuan)聯(lian)時上節的低(di)壓(ya)側(ce)與下(xia)節高壓(ya)側(ce)連接。諧振電抗器(qi)采用多臺(tai)串(chuan)聯(lian)或并聯(lian)的連接方式(shi)。
8.額(e)定(ding)(ding)容量下連續運行為規定(ding)(ding)工作時間下,電(dian)抗(kang)器對(dui)空氣(qi)的溫升不大于60K;
9.性能及特點(dian):電(dian)(dian)抗器(qi)設計干式、環氧澆鑄(zhu),電(dian)(dian)抗器(qi)可以自由方便疊裝(zhuang)。環氧樹脂(zhi)絕緣筒外殼(ke),具有足夠的電(dian)(dian)氣、機械強度,必要的散熱能力以及油(you)熱脹冷縮(suo)的裕度。外殼(ke)上下蓋板,顏色(se)為(wei)橘紅(hong)色(se)。
十、電(dian)容分(fen)壓器技(ji)術參(can)數:
額定(ding)電壓:200kV;
工作(zuo)頻率:30~300Hz;
分壓比:2000:1;
分壓比誤差(cha):1%;
電容分壓器(qi)接線端子如圖所示(shi):
高壓(ya)端—與電抗(kang)器高壓(ya)側(ce)及被試品高壓(ya)側(ce)相連。
測(ce)量(liang)插座—采用專配(pei)的測(ce)量(liang)電纜與控制(zhi)箱背板測(ce)量(liang)輸入端連(lian)接。
接(jie)(jie)地端—采用專配接(jie)(jie)地線按接(jie)(jie)線圖指示接(jie)(jie)地。
4.性能及(ji)特點:
a.額定(ding)電壓下可(ke)連續運行2小時。
b.在30~300Hz范圍內,其(qi)精度和穩定(ding)度保持(chi)不變(bian)。
c.在20℃溫度下電容分壓器(qi)介質損耗值≤0.0025
d.電容分壓器配有(you)支撐底架,具有(you)足(zu)夠的穩(wen)定性。
e.電(dian)壓測量(liang)通(tong)過專用測試引(yin)線引(yin)至調頻電(dian)源(yuan)進行測量(liang)。
試驗接(jie)線圖(tu):
110kv主(zhu)變、GIS試驗接線
35kv電纜(lan)試(shi)驗接線圖
10kv電纜(lan)試驗接線(xian)圖
十二、設備保(bao)存和維護
1、存放于干(gan)燥(zao)、清潔場(chang)地,防止雨水(shui)、灰塵進(jin)入(ru)部件內部;
2、如若長期不(bu)(bu)使用,正常(chang)天氣至少2個(ge)月(yue)應通電(dian)一(yi)(yi)次時(shi)間不(bu)(bu)少于半(ban)(ban)小時(shi),雨季(ji)及(ji)潮濕期應每隔(ge)一(yi)(yi)個(ge)月(yue)通電(dian)一(yi)(yi)次,通電(dian)時(shi)間半(ban)(ban)小時(shi),以(yi)驅除設備(bei)內(nei)的潮氣防(fang)止電(dian)子元(yuan)器件(jian)的銹(xiu)蝕,影響正常(chang)使用。
3、定期檢查(cha)裝(zhuang)置各部件,確(que)保各接頭(tou)緊固無松(song)動(dong);
4、更換(huan)打(da)(da)印紙,機器采用熱敏(min)打(da)(da)印紙并(bing)且是(shi)前換(huan)紙式當(dang)需要(yao)換(huan)紙時只要(yao)按POST鍵鈕打(da)(da)印紙艙(cang)門(men)就(jiu)會打(da)(da)開(kai)可以(yi)將(jiang)新打(da)(da)印紙裝入;
十三、常見故障排除
故(gu)障現象
|
發(fa) 生 原 因
|
排 除 方 法(fa)
|
找不(bu)到諧(xie)振點
|
接線有誤。
輸出開關未開,;
3、做GIS時PT二次回路(lu)未打開;
4、試品Q值太低;
5、起始激勵功率太低;
6、試驗(yan)回路有短路現象(xiang);
7、找頻范圍不(bu)對。
|
退出試(shi)驗狀態,合上輸出開(kai)關,檢查接線;打開(kai)PT二次回(hui)路;
調高起始(shi)功率(∠30%);
用兆歐表(biao)測量(liang)試品絕緣(yuan)
重(zhong)新設置找(zhao)頻范(fan)圍
|
諧振(zhen)后,電壓升(sheng)不上去
|
1、試品Q值太低(di);
2、激勵電(dian)壓(ya)不夠(gou);
3、電抗器底部有鐵磁物體;
4、3次諧波諧振。
|
檢查試品;
改(gai)變激勵(li)(li)變壓器繞組(zu)接法,提(ti)高勵(li)(li)磁電壓
絕緣(yuan)筒架高電抗(kang)器或離開鐵(tie)磁物體(ti)。
|
主機自動(dong)復位(wei)
|
供電(dian)電(dian)源容量不(bu)夠(gou);
電(dian)源(yuan)引線過(guo)長(chang)或線徑(jing)過(guo)小(xiao);
接頭處接觸**;
供電電壓波動(dong);
按鍵死接(jie)觸。
|
增加供(gong)電(dian)電(dian)源容量;
換較粗(cu)導(dao)線(xian),減小導(dao)線(xian)長(chang)度;
檢查(cha)接頭;
減小供電(dian)電(dian)壓波動。
|
開機后線路跳閘
|
線路(lu)漏(lou)電保護(hu)器較(jiao)為敏感;
空氣開(kai)關容量(liang)不夠。
|
跨(kua)過漏電保護器或空氣開關(guan)的接(jie)線;
改換較(jiao)大容(rong)量的空氣開關。
|
電(dian)壓(ya)跌落(luo)
|
試(shi)品放電(dian)或(huo)擊穿(chuan)
|
檢查試品
|
輸出短路
|
電(dian)流超過本機限流值(zhi)。
|
檢查接線和(he)試品(pin)。
|
試(shi)品電(dian)壓不準(zhun)
|
分壓比設置錯誤(wu)或分壓器信號傳輸有(you)問題。
|
重設分(fen)壓比(bi)或檢(jian)查(cha)分(fen)壓器接線。
|
電壓閃變(bian)
|
試驗(yan)電壓劇烈波動,變化率超過本機限(xian)定(ding)值。
|
檢(jian)查供電(dian)電(dian)源電(dian)壓(ya)穩定(ding)性(xing)或試(shi)品參數的變(bian)化。
|
回路無電(dian)流
|
|
檢查接線和試品。
|
未(wei)接好地線
|
|
檢查(cha)接地線和地樁,按(an)說明書要(yao)求連接。
|
試品(pin)過電(dian)壓(ya)
|
手(shou)動升壓太快或失控。
|
改變調(diao)壓步距或改用自動升壓 。
|
系(xi)統不諧振
|
接線(xian)有(you)誤(wu)或試品(pin)Q值太低。
|
檢查接線和試(shi)品
|
十四、常用設備(bei)資料(liao)參考
交聯聚乙烯電纜單(dan)位長度電容(rong)量(liang)
電纜導體截面積(平方毫米)
|
電 容 (μ/km)
|
YJV、YJLV
|
YJV、YJLV
|
YJV、YJV、YJLV
|
YJV、YJLV
|
YJV、YJLV
|
6/6kV、6/10kV
|
8.7/10kV、8.7/15kV
|
12/35kV
|
21/35kV
|
26/35kV
|
1×35
|
0.212
|
0.173
|
0.152
|
|
|
1×50
|
0.237
|
0.192
|
0.166
|
0.118
|
0.114
|
1×70
|
0.270
|
0.217
|
0.187
|
0.131
|
0.125
|
1×95
|
0.301
|
0.240
|
0.206
|
0.143
|
0.135
|
1×120
|
0.327
|
0.261
|
0.223
|
0.153
|
0.143
|
1×150
|
0.358
|
0.284
|
0.241
|
0.164
|
0.153
|
1×185
|
0.388
|
0.307
|
0.267
|
0.180
|
0.163
|
1×240
|
0.430
|
0.339
|
0.291
|
0.194
|
0.176
|
1×300
|
0.472
|
0.370
|
0.319
|
0.211
|
0.190
|
1×400
|
0.531
|
0.418
|
0.352
|
0.231
|
0.209
|
1×500
|
0.603
|
0.438
|
0.388
|
0.254
|
0.232
|
1×600
|
0.667
|
0.470
|
0.416
|
0.287
|
0.256
|
2、交聯聚乙烯(xi)電纜單位長度電容量
電纜導(dao)體截面積(平方毫(hao)米)
|
電 容 (μF/km)
|
YJV、YJLV
|
YJV、YJLV
|
YJV、YJV、YJLV
|
YJV、YJLV
|
YJV、YJLV
|
6/6kV、6/10kV
|
8.7/10kV、8.7/15kV
|
12/35kV
|
21/35kV
|
26/35kV
|
3×35
|
0.212
|
0.173
|
0.152
|
|
|
3×50
|
0.237
|
0.192
|
0.166
|
0.118
|
0.114
|
3×70
|
0.270
|
0.217
|
0.187
|
0.131
|
0.125
|
3×95
|
0.301
|
0.240
|
0.206
|
0.143
|
0.135
|
3×120
|
0.327
|
0.261
|
0.223
|
0.153
|
0.143
|
3×150
|
0.358
|
0.284
|
0.241
|
0.164
|
0.153
|
3×185
|
0.388
|
0.307
|
0.267
|
0.180
|
0.163
|
3×240
|
0.430
|
0.339
|
0.291
|
0.194
|
0.176
|
3×300
|
0.472
|
0.370
|
0.319
|
0.211
|
0.190
|
3×400
|
0.531
|
0.418
|
0.352
|
0.231
|
0.209
|
3×500
|
0.603
|
0.438
|
0.388
|
0.254
|
0.232
|
3×600
|
0.667
|
0.470
|
0.416
|
0.287
|
0.256
|
3、交聯聚乙烯電纜(lan)單位長度電容量
電纜導(dao)體(ti)截(jie)面積(平方毫(hao)米(mi))
|
電 容 (μF/km)
|
YJV、YJLV
|
YJV、YJLV
|
64/110kV
|
128/220kV
|
3×240
|
0.129
|
|
3×300
|
0.139
|
|
3×400
|
0.156
|
0.118
|
3×500
|
0.169
|
0.124
|
3×630
|
0.188
|
0.138
|
3×800
|
0.214
|
0.155
|
3×1000
|
0.231
|
0.172
|
3×1200
|
0.242
|
0.179
|
3×1400
|
0.259
|
0.190
|
3×1600
|
0.273
|
0.198
|
3×1800
|
0.284
|
0.297
|
3×2000
|
0.296
|
0.215
|
3×2200
|
|
0.221
|
3×2500
|
|
0.232
|
4、60kV級(ji)全絕緣變壓器的電容(rong)(pF)
類(lei) 型
|
變 壓 器 容 量(liang) kVA
|
630
|
2000
|
3150
|
6300
|
8000
|
1600
|
高壓-地
|
2700
|
4100
|
4600
|
5900
|
7000
|
8200
|
低(di)壓(ya)-地
|
4200
|
6600
|
7900
|
10000
|
11000
|
15300
|
對于表中沒有的產品,可根據表中的上、下容(rong)量近似地估算(suan)。同容(rong)量的雙繞組變壓器,其繞組電容(rong)要比三繞組產品小。
5、110kV級中性點分(fen)級絕緣變(bian)壓器(qi)的電容(pF)
類 型(xing)
|
變(bian) 壓 器 容 量kVA
|
50000
|
31500
|
20000
|
10000
|
5600
|
高壓-中壓、低壓、地
|
14200
|
11400
|
8700
|
6150
|
4200
|
中壓(ya)(ya)-高壓(ya)(ya)、低壓(ya)(ya)、地
|
24800
|
11800
|
13200
|
9600
|
-
|
低壓(ya)-高(gao)壓(ya)、中壓(ya)、地
|
19300
|
19300
|
12000
|
9400
|
6800
|
6、220kV級中性點非全級絕(jue)緣部分變(bian)壓器(qi)的電容(pF)
試 品 型 號
|
SEPSL-63000
|
SSPSL-120000
|
SSPSL-240000
|
類 型
|
高壓(ya)-中壓(ya)、低(di)壓(ya)及地
|
12100
|
13500
|
17050
|
中壓-高壓、低壓及地
|
18500
|
19700
|
23260
|
低(di)壓(ya)-高壓(ya)、中(zhong)壓(ya)及地
|
18200
|
23600
|
29940
|
試 品 型 號
|
SFPL-240000
|
SFP-360000
|
SFPSZL-120000
|
類 型
|
高(gao)壓(ya)-中(zhong)壓(ya)、低壓(ya)及地
|
32230
|
33910
|
38020
|
中壓-高壓、低(di)壓及地(di)
|
-
|
-
|
23260
|
低壓-高(gao)壓、中壓及地
|
22470
|
23790
|
22160
|
7、油浸式電力(li)變壓(ya)器交流試驗電壓(ya)
額(e)定電(dian)壓
(k V)
|
*高工作
電(dian)壓(ya)(k V)
|
線端交流試(shi)驗電壓值(zhi)(kV)
|
中性點交(jiao)流試驗電壓值(kV)
|
全部更換繞組
|
部分更換(huan)繞組(zu)或交接
|
全部更(geng)換繞組
|
部分更換繞組(zu)或交接
|
<1
|
≤1
|
3
|
2.5
|
3
|
2.5
|
3
|
3.5
|
18
|
15
|
18
|
15
|
6
|
6.9
|
25
|
21
|
25
|
21
|
10
|
11.5
|
35
|
30
|
35
|
30
|
15
|
17.5
|
45
|
38
|
45
|
38
|
20
|
23.0
|
55
|
47
|
55
|
47
|
35
|
40.5
|
85
|
72
|
85
|
72
|
110
|
126.0
|
200
|
170(195)
|
95
|
80
|
220
|
252.0
|
360
|
306
|
85
|
72
|
395
|
336
|
(200)
|
(170)
|
500
|
550.0
|
630
|
536
|
85
|
72
|
680
|
578
|
140
|
120
|
8、部(bu)分型號發電(dian)機(ji)定(ding)子(zi)繞組的(de)單相對地電(dian)容量
類(lei)別
|
發(fa) 電(dian) 機
|
型號
|
生產廠家
|
額定容量(MW)
|
額定電壓(kV)
|
相電(dian)容(mF)
|
火
力(li)
發
電
機(ji)
|
QFS-125-2
|
上海電(dian)機廠
|
125
|
13.8
|
0.08-0.12
|
QFSN-200-2
|
哈(ha)爾濱(bin)電機廠(chang)
|
200
|
15.75
|
0.19-0.21
|
QFQS-200-2
|
東方(fang)電機廠
|
200
|
15.75
|
0.1928-0.21
|
QFQS-200-2
|
北(bei)京重型電機廠
|
200
|
15.75
|
0.18-0.19
|
QFS-300-2
|
上海電機廠(chang)
|
300
|
18.0
|
0.16-0.20
|
QFSN-300-2
|
上海電機廠(chang)
|
300
|
18.0
|
0.18-0.20
|
ATB-2
|
美國GE公司
|
352
|
23.0
|
0.268(設計值(zhi))
|
TBB-320-2
|
(前蘇(su)聯)
|
320
|
20.0
|
0.31
|
2-105×234
|
美(mei)國西(xi)屋公司(si)
|
600
|
20.0
|
0.2(工廠試驗值)
|
50WT23E-138
|
ABB
|
600
|
22.0
|
0.253(設計(ji)值)
|
水 發
力 電
機(ji)
|
|
|
72.5 - 85
|
10.5
|
0.694
|
|
|
300
|
15.75
|
1.7-2.5
|
|
|
400
|
18.0
|
2-2.5
|
9、同(tong)步發(fa)電機定子繞組交流試(shi)驗(yan)電壓
1
|
全(quan)部更換(huan)定子繞組并修好后的試驗(yan)電壓(ya)
|
容量kW或kVA
|
小于10000
|
10000及以上
|
額定電壓Un (V)
|
36以上
|
6000以(yi)下
|
6000~18000
|
18000以上
|
試驗電壓(ya)V
|
2Un+1000但*低為1500
|
2.5Un
|
2Un
+3000
|
按(an)專門協議
|
2
|
大修前(qian)或局部更(geng)換定子繞組并修好后的試驗電(dian)壓(ya)
|
運(yun)行20年及以下者(zhe)
|
1.5 Un
|
運行(xing)20年(nian)以上與(yu)架空(kong)線路(lu)直接連接者
|
1.5 Un
|
運行20年以上不與架空線(xian)路直接連接者(zhe)
|
(1.3~1.5)Un
|
十五、設備成套性:
變頻電(dian)源 1臺
勵磁變壓器(qi) 1臺
電(dian)抗器 4臺
電容(rong)分壓器 1臺(tai)
附件及測試線 1套
支架(jia) 15KV 1只
均壓罩 200KV 2只
絕緣(yuan)底板 2塊
一、產品概述(shu)
YDQC系列(lie)輕型交(jiao)直(zhi)(zhi)流高(gao)壓(ya)(ya)(ya)試(shi)驗(yan)變壓(ya)(ya)(ya)器是在同類(lei)產(chan)(chan)品YDJ(G)型高(gao)壓(ya)(ya)(ya)試(shi)驗(yan)變壓(ya)(ya)(ya)器的(de)基礎上,按試(shi)驗(yan)變壓(ya)(ya)(ya)器國家標準ZBK41006—89要求(qiu),經(jing)改進后生產(chan)(chan)的(de)一種新型產(chan)(chan)品,本系列(lie)產(chan)(chan)品具(ju)有(you)體(ti)積(ji)小(xiao)、重(zhong)量輕、結構緊湊、功能齊(qi)全、使用(yong)方便(bian)等特點。實(shi)用(yong)于電(dian)力、工礦、科研(yan)等部門(men),對各種高(gao)壓(ya)(ya)(ya)電(dian)氣設備、電(dian)氣元件、絕(jue)緣材(cai)料進行工頻耐壓(ya)(ya)(ya)試(shi)驗(yan)和直(zhi)(zhi)流泄漏試(shi)驗(yan),是高(gao)壓(ya)(ya)(ya)試(shi)驗(yan)中必(bi)不可少的(de)儀器。
二、產(chan)品結構
YDQC系列(lie)輕型高(gao)(gao)壓試驗變壓器(qi)鐵(tie)芯(xin)為單(dan)框式。線(xian)圈采用同芯(xin)圓筒多(duo)層塔式結(jie)構,初級低壓繞(rao)(rao)組繞(rao)(rao)在鐵(tie)芯(xin)上(shang),次級高(gao)(gao)壓繞(rao)(rao)組繞(rao)(rao)在低壓繞(rao)(rao)組外(wai)(wai)側,這種同軸布置(zhi)減(jian)少了繞(rao)(rao)組間的藕合損耗。高(gao)(gao)壓硅堆用特殊(shu)工藝封裝(zhuang)在套管內,產品的外(wai)(wai)殼制(zhi)成(cheng)與器(qi)芯(xin)配合較佳的八角形(xing)結(jie)構,整體外(wai)(wai)型美觀大方(fang)。其內外(wai)(wai)部結(jie)構見圖1。
1-均壓球(qiu);2-硅(gui)堆短路桿;3-高(gao)壓套管;4-油(you)閥;5-殼(ke)體(ti);6、7-調整電壓輸(shu)入a、x端子(zi)(zi)(zi);8、9-儀表測量(liang)E、F端子(zi)(zi)(zi);10-高(gao)壓尾X端子(zi)(zi)(zi);11-變(bian)壓器(qi)外殼(ke)接地端;12-高(gao)壓輸(shu)出A端子(zi)(zi)(zi);13-高(gao)壓整流硅(gui)堆;14-內部(bu)均壓環(huan);15-變(bian)壓器(qi)鐵芯;16-初級(ji)低壓繞(rao)組;17-測量(liang)儀表繞(rao)組;18-二次級(ji)高(gao)壓繞(rao)組;19-變(bian)壓器(qi)油(you)。
三、工(gong)作原理
YDQC系列輕型高壓(ya)(ya)(ya)試(shi)(shi)驗(yan)變(bian)(bian)壓(ya)(ya)(ya)器(qi)(qi)為單相變(bian)(bian)壓(ya)(ya)(ya)器(qi)(qi),聯結組(zu)標號II。單臺(tai)(tai)高壓(ya)(ya)(ya)試(shi)(shi)驗(yan)變(bian)(bian)壓(ya)(ya)(ya)器(qi)(qi)的工作過程(cheng),用交流(liu)220V(10KVA以上(shang)(shang)為380V)電(dian)壓(ya)(ya)(ya)接入(ru)電(dian)源控(kong)制箱(臺(tai)(tai)),經(jing)電(dian)源控(kong)制箱(臺(tai)(tai))內自藕調(diao)壓(ya)(ya)(ya)器(qi)(qi)(50KVA以上(shang)(shang)調(diao)壓(ya)(ya)(ya)器(qi)(qi)外附)調(diao)節(jie)0~200V(10KVA以上(shang)(shang)0~400V)電(dian)壓(ya)(ya)(ya)至(zhi)試(shi)(shi)驗(yan)變(bian)(bian)壓(ya)(ya)(ya)器(qi)(qi)的初級繞組(zu),根據電(dian)磁感應原理(li),在試(shi)(shi)驗(yan)變(bian)(bian)壓(ya)(ya)(ya)器(qi)(qi)高壓(ya)(ya)(ya)繞組(zu)可獲得試(shi)(shi)驗(yan)所需的高電(dian)壓(ya)(ya)(ya)。其(qi)工作原理(li)圖見(jian)圖2所示。
1、單臺YDQC高(gao)壓(ya)試驗變壓(ya)器工作原理(li)示意圖(tu)
在試驗變壓器中:a、x為低(di)壓輸(shu)入端;A、X 為高壓輸(shu)出端;E、F為儀表(biao)測量端。
2、單臺交直流兩用型高壓試驗變壓器工作原理見圖3。圖中所示:高壓套管內裝有高壓硅堆,串接在高壓回路中作高壓整流,以獲得直流高電壓。當用一短路桿將高壓硅堆短接時,可獲得交流高電壓,其狀態為交流輸出;反之在抽出短路桿時,其狀態為直流輸出。
3、三臺高壓試驗變壓器串激獲得更高電壓原理見圖4,串激高壓試驗變壓器有很大的優越性,因為整個試驗裝置由多個單臺串激式試驗變壓器組成,單臺試驗變壓器有著體積小、重量輕、便于運輸的特點,它既可以串接成高出幾倍的單臺試驗變壓器輸出電壓組合使用,又可以分開單獨使用。整套試驗裝置投資小、經濟實惠。圖3所示:在三臺串激式試驗變壓器串激使用中,單臺試驗變壓器B1、B2、B3的輸出電壓都是U,**、二級的試驗變壓器內部都有一個激磁繞組,分別為A1、C1 和A2、C2。當控制電壓加在第**試驗變壓器B1的初級繞組a1、x1上,激磁繞組A1、C1給予試驗變壓器B2初級繞組供電,**級試驗變壓器B2的激磁繞組A2、C2給試驗變壓器B3的初級繞組供電。由于第**試驗變壓器B1的高壓尾及殼體接地,**、三級的試驗變壓器B2和B3對地有絕緣支架的隔離,這樣試驗變壓器B1、B2、B3對地輸出電壓分別為1U、2U、3U。
B1、B2、B3- 串激式高壓(ya)(ya)變壓(ya)(ya)器;1U、2U、3U-各級對地電(dian)壓(ya)(ya);
PV- 高(gao)壓(ya)示(shi)值(zhi)表(KV); ZJ1、ZJ2-絕(jue)緣支架。
四、使用方法及注(zhu)意(yi)事項(xiang)
1、YDQC高壓試(shi)(shi)(shi)驗(yan)(yan)(yan)變壓器做工(gong)頻耐壓試(shi)(shi)(shi)驗(yan)(yan)(yan)使用(yong)接(jie)(jie)線方法見(jian)圖(tu)5。做工(gong)頻耐壓試(shi)(shi)(shi)驗(yan)(yan)(yan)前,先根據(ju)試(shi)(shi)(shi)驗(yan)(yan)(yan)變壓器的額定容量選擇好限流電(dian)(dian)阻,(水電(dian)(dian)阻)的阻值,再(zai)根據(ju)被試(shi)(shi)(shi)品需加的高壓電(dian)(dian)壓值調(diao)整好放電(dian)(dian)球隙的球間距,為了提高對(dui)被試(shi)(shi)(shi)品施加電(dian)(dian)壓的測量精度(du),應在高壓側接(jie)(jie)入FRC阻容分(fen)壓器來測量電(dian)(dian)壓。
R1、R2- 限流電阻; Qx- 放電球隙(xi); Zx- 被試品;
FRC- 阻容分壓器; V- 分壓器高壓表。
按照圖4、結合圖2所進行的工頻耐壓試驗接好工作線路,試驗變壓器的高壓繞阻的X端(高壓尾)、儀表測量繞組的F端、試驗變壓器的外殼以及電源控制箱(臺)的外殼必須可靠接地。
用三臺試驗變壓器串激做工頻耐壓試驗時、**、三級試驗變壓器的初級繞組X端,儀表測量繞組的F端,以及高壓繞組的X端(高壓尾)均接本級試驗變壓器的外殼,**、三級試驗變壓器的主體必須放置在絕緣支架上。除第**以外、**、三級試驗變壓器的主體不要接地線。其接線方式見圖3所示。
接電源前,電源控制箱(臺)的調壓器必須調到零位。接通電源后,綠色指示燈亮,按一下啟動按鈕,紅色指示燈亮,表示試驗變壓器已接通控制電源,開始升壓。
從零位開始按順時針方向勻速旋轉調壓器手輪升壓。(升壓方式有:快速升壓法,即20S逐級升壓法,慢速升壓法,即60S逐級升壓法,極慢速升壓法供選用)電壓從零開始按選定的升壓速度升到您所需額定試驗電壓的75%后,再以每秒2%額定試驗電壓的速度升到您所需試驗電壓,并密切注意測量儀表的指示以及被試品的情況,被試品施加電壓的時間到后。應在數秒內勻速將調壓器返回,高壓降至1/3試驗電壓以下,按一下停止按鈕,高壓、低壓輸出停止,然后切斷電源線,試驗完畢。
工頻耐壓試驗操作過程注(zhu)意事項
1、試驗人員應做好責任分工,設定好試驗現場的**距離,仔細檢查好被試品及試驗變壓器的接地情況,并設有專人監護**及觀察被試品狀態工作。
2、被試品主要部位應**干凈,保持**干燥,以免損壞被試品和帶來試驗數值的誤差。
3、對大型設備的試驗,一般都應先進行試驗變壓器的空升試驗,即不接試品時升壓至試驗電壓,以便校對好儀表的指示精度,調整好放電球隙的球間距。
4、做耐壓試驗時升壓速度不能過快,并防止突然加壓,例如調壓器不在零位的突然合閘,也不能突然斷電,一般應在調壓器降至零位時分閘。
5、在升壓或耐壓試驗過程中,如發現下列不正常情況,1 電壓、電流表指針擺動很大,2 被試品發出不正常響聲,3 發現絕緣有燒焦或冒煙現象,應立即降壓,切斷電源,停止試驗并查明原因。
6、使用本產品做高壓試驗時,除熟悉本說明書外,還必須嚴格執行國家有關標準和操作規程。
2、YDQ交直(zhi)(zhi)流(liu)(liu)(liu)兩(liang)用(yong)高(gao)壓(ya)(ya)(ya)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)壓(ya)(ya)(ya)器(qi)(qi)做直(zhi)(zhi)流(liu)(liu)(liu)耐(nai)壓(ya)(ya)(ya)和(he)泄漏(lou)(lou)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)使(shi)用(yong)接線方(fang)法見(jian)圖5。由于是交直(zhi)(zhi)流(liu)(liu)(liu)兩(liang)用(yong)高(gao)壓(ya)(ya)(ya)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)壓(ya)(ya)(ya)器(qi)(qi),應把高(gao)壓(ya)(ya)(ya)硅(gui)堆短路(lu)桿從套管中抽出,使(shi)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)壓(ya)(ya)(ya)器(qi)(qi)為直(zhi)(zhi)流(liu)(liu)(liu)輸出狀態(tai)。做直(zhi)(zhi)流(liu)(liu)(liu)泄漏(lou)(lou)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)前,先根(gen)據泄漏(lou)(lou)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)中輸出端斷路(lu)電(dian)流(liu)(liu)(liu)不超過高(gao)壓(ya)(ya)(ya)硅(gui)堆的*大整流(liu)(liu)(liu)為宜,選(xuan)擇好(hao)限流(liu)(liu)(liu)電(dian)阻(zu)(水電(dian)阻(zu))的阻(zu)值,再根(gen)據被試(shi)(shi)(shi)(shi)(shi)(shi)品(pin)對直(zhi)(zhi)流(liu)(liu)(liu)高(gao)壓(ya)(ya)(ya)波形的要求選(xuan)擇好(hao)高(gao)壓(ya)(ya)(ya)濾波電(dian)容的電(dian)容值。為了提高(gao)對被試(shi)(shi)(shi)(shi)(shi)(shi)品(pin)施加電(dian)壓(ya)(ya)(ya)的測量精度,應在高(gao)壓(ya)(ya)(ya)側接入FRC阻(zu)容分壓(ya)(ya)(ya)器(qi)(qi)來測量電(dian)壓(ya)(ya)(ya)。
R- 限流電(dian)阻(zu); C- 高壓濾波電(dian)容; Zx- 被試品; G- 硅堆短(duan)路桿;
FRC- 阻容分壓器;V- 分壓器高壓表;uA- 微安表;D- 高壓整流硅堆。
按照圖5、結合圖3所進行的直流泄漏試驗接好工作線路。試驗變壓器的高壓繞組的X端(高壓尾)、儀表測量繞組的F 端、試驗變壓器的外殼以及電源控制箱(臺)的外殼必須可靠接地。
接電(dian)源前、電(dian)源控(kong)(kong)制箱(臺)的調(diao)壓器(qi)必須調(diao)到(dao)零位。接通電(dian)源后,綠(lv)色(se)指(zhi)示燈亮(liang),按一下(xia)啟動按鈕,紅(hong)色(se)指(zhi)示燈亮(liang),表示試驗變壓器(qi)已接通控(kong)(kong)制電(dian)源,開始升(sheng)壓。
從零位開(kai)始(shi)按(an)順時針方(fang)向(xiang)勻(yun)速(su)(su)旋(xuan)轉調壓(ya)(ya)(ya)器手(shou)輪升(sheng)(sheng)壓(ya)(ya)(ya)。(升(sheng)(sheng)壓(ya)(ya)(ya)方(fang)式(shi)有:快速(su)(su)升(sheng)(sheng)壓(ya)(ya)(ya)法(fa)即20S逐級(ji)升(sheng)(sheng)壓(ya)(ya)(ya)法(fa);慢速(su)(su)升(sheng)(sheng)壓(ya)(ya)(ya)法(fa),即60S逐級(ji)升(sheng)(sheng)壓(ya)(ya)(ya)法(fa);級(ji)慢速(su)(su)升(sheng)(sheng)壓(ya)(ya)(ya)法(fa)供選用)電(dian)(dian)壓(ya)(ya)(ya)從零開(kai)始(shi)按(an)選定(ding)(ding)的(de)(de)升(sheng)(sheng)壓(ya)(ya)(ya)速(su)(su)度升(sheng)(sheng)到您(nin)所需額定(ding)(ding)試(shi)驗電(dian)(dian)壓(ya)(ya)(ya)或額定(ding)(ding)直流電(dian)(dian)流下(xia)(xia)的(de)(de)參(can)考電(dian)(dian)壓(ya)(ya)(ya)。試(shi)驗中應嚴密注意直流高(gao)(gao)壓(ya)(ya)(ya)表、泄漏(lou)電(dian)(dian)流表指(zhi)示(shi)以及被試(shi)品的(de)(de)情況。試(shi)驗完畢后,應訊(xun)速(su)(su)均勻(yun)將高(gao)(gao)壓(ya)(ya)(ya)降至零位,按(an)一下(xia)(xia)停(ting)止(zhi)按(an)鈕,高(gao)(gao)壓(ya)(ya)(ya)、低壓(ya)(ya)(ya)輸出停(ting)止(zhi),然后切斷電(dian)(dian)源。此時應用直流高(gao)(gao)壓(ya)(ya)(ya)放**給被試(shi)品及試(shi)驗裝置(zhi)本身(shen)充分放電(dian)(dian)。
直流泄(xie)漏試驗操(cao)作(zuo)過程注意(yi)事項
(1)試驗人員應做好責任分工,設定好試驗現場的**距離,仔細檢查好被試品及試驗變壓器的接地情況,并設有專人監護**及觀察被試品狀態工作。
(2)被試品做試驗前,應拆除所有對外連線,并充分放電,主要部位應**干凈,保持**干燥,以免損壞被試品及帶來試驗數值的誤差。
(3)對于大容量試品(電容器、超長電纜等)試驗時應緩慢升壓,防止被試品的充電電流過大而燒壞微安表,必要時應分級加壓分別讀取各電壓下微安表的穩定讀數。
(4)試驗過程中,應嚴密監視被試品、微安表及試驗裝置等,一旦發生閃爍、擊穿等現象應立即降壓,切斷電源,并查明原因。
五、配套選購產品
下列產品僅供選擇,購買時需另行計價。
1.KZX系列電源控制箱 容量:1KVA-5KVA、輸入電壓:220V
2.KZT系列電源控制臺 容量:10KVA~300KVA輸入電壓:220V或380V
3.數字微安表:SWB-II
4.高壓濾波電容: 0.01MF、40 ~ 100KV
5.高壓直流放**: FBR— 70、140、210KV
6.放電球隙: Q—50、100、150、200、250、500
7.標準試油杯: 400ml
8.折疊式手推車: 150、300型
9.絕緣支架: 50、100、200、300、400KV
10.阻容分壓器: FRC —50、100、150、200KV
11.高壓硅堆: 2DL—150、300、450KV
12.水 電 阻: 50、100
六(liu)、主要試驗設備(bei)的選擇
1、試驗變壓器
其高壓側額定電壓應不小于被試品的*高試驗電壓,額定電流不小于被試品的*大電容電流。被試品的電容電流和試驗變壓器所需容量計算式為:
被試(shi)品電容(rong)量Cx可由交(jiao)流電橋測出。常用的被試(shi)品電容(rong)量按表1選取。
幾種(zhong)常用被試品的電容量(pF) 表1
2、調(diao)壓設備
(1)自藕調壓器。其調壓范圍廣、功率損耗小、波形畸變小、選擇這種調壓方式為*好。自藕調壓器的容量按0.75 ~ 1倍的試驗變壓器的容量選擇,適用于容量為100KVA以下的試驗變壓器的調壓。
(2)感應調壓器。其調壓范圍大,波形畸形小、但結構復雜、價格較貴,當試驗變壓器的容量較大時(如100KVA以上)使用。
3、限流電阻
限流電阻的作用是,當被試品擊穿時,限制斷路電流,從而保護試驗變壓器,防止故障的擴大。其數值以*高試驗電壓為準,按0.5 ~ 1 Ω / V(有效值)選擇,限流電阻可用水電阻。注意水不能充滿玻璃管,應留有余地,以防爆裂。
4、放電球隙
放電球隙的布置方式有垂直和水平兩種,球隙間距S和球的直徑D的關系應保護在0.05D ≤S ≤0.5D范圍內,球隙上的水電阻阻值一般按0.1 ~ 1Ω/V選取,設置放電球隙的目的是為了對重要的被試品起保護作用,可以將由于誤操作或被試品擊穿引起的過電壓限制在允許的范圍內。
七(qi)、試驗變壓(ya)器(qi)技術指示
型號
|
容量
|
高壓電壓
|
高壓電(dian)流
|
低壓(ya)輸入
|
變(bian)比
|
溫升℃
|
(KVA)
|
(KV)
|
(mA)
|
電壓(V)
|
電(dian)流(A)
|
高/儀
|
30分鐘
|
YDQC-1.5/50
|
1.5
|
50
|
30
|
200
|
7.5
|
500
|
10
|
YDQC-3/50
|
3
|
50
|
60
|
200
|
15
|
500
|
10
|
YDQC-5/50
|
5
|
50
|
100
|
200
|
25
|
500
|
10
|
YDQC-10/50
|
10
|
50
|
200
|
200
|
50
|
500
|
10
|
YDQC-15/50
|
15
|
50
|
300
|
200
|
75
|
500
|
10
|
YDQC-20/50
|
20
|
50
|
400
|
380
|
53
|
500
|
10
|
YDQC-30/50
|
30
|
50
|
600
|
380
|
79
|
500
|
10
|
YDQC-50/50
|
50
|
50
|
1000
|
380
|
12
|
500
|
10
|
YDQC-5/100
|
5
|
100
|
50
|
200
|
25
|
1000
|
10
|
YDQC-10/100
|
10
|
100
|
100
|
200
|
50
|
1000
|
10
|
YDQC-20/100
|
20
|
100
|
200
|
400
|
50
|
1000
|
10
|
YDQC-30/100
|
30
|
100
|
300
|
400
|
75
|
1000
|
10
|
YDQC-50/100
|
50
|
100
|
500
|
400
|
125
|
1000
|
10
|
YDQC-20/150
|
20
|
150
|
133
|
400
|
50
|
1500
|
10
|
YDQC-30/150
|
30
|
150
|
200
|
400
|
75
|
1500
|
10
|
YDQC-50/150
|
50
|
150
|
333
|
400
|
125
|
1500
|
10
|
YDQC-100/150
|
100
|
150
|
667
|
400
|
250
|
1500
|
10
|
YDQC-50/200
|
50
|
200
|
250
|
400
|
125
|
2000
|
10
|
YDQC-100/200
|
100
|
200
|
500
|
400
|
250
|
2000
|
10
|
YDQC-150/200
|
150
|
200
|
750
|
400
|
375
|
2000
|
10
|
YDQC-200/200
|
200
|
200
|
1000
|
400
|
500
|
2000
|
10
|
YDQC-300/200
|
300
|
200
|
1500
|
400
|
600
|
2000
|
10
|
YDQC-50/300
|
50
|
300
|
170
|
400
|
125
|
3000
|
10
|
YDQC-100/300
|
100
|
300
|
333
|
400
|
250
|
3000
|
10
|
YDQC-150/300
|
150
|
300
|
500
|
400
|
375
|
3000
|
10
|
YDQC-200/300
|
200
|
300
|
667
|
400
|
500
|
3000
|
10
|
YDQC-300/300
|
300
|
300
|
3000
|
500
|
600
|
3000
|
10
|
1、使用環境條件
環境溫度不高于+40℃、不低于—20℃;空氣相對濕度不大于90%;海拔高度不超過2000米;
2、工作電壓
電源控制箱(臺)輸入電壓為工頻220V或380V、相對誤差不超過±10%;(具體使用電壓根據用戶所定試驗變壓器規格選取)
八、隨貨文件
YDQC 系列試驗變壓器產品說明書 1份
產品出廠試驗報告 1份
產品合格證 1份
裝箱單 1份
一、概(gai)述
YDQ系(xi)列高壓(ya)(ya)(ya)(ya)試驗變(bian)壓(ya)(ya)(ya)(ya)器是(shi)(shi)根據《試驗變(bian)壓(ya)(ya)(ya)(ya)器》標(biao)準,在(zai)油浸式(shi)試驗變(bian)壓(ya)(ya)(ya)(ya)器的(de)(de)(de)(de)基礎(chu)上(shang)而設(she)計(ji)生產的(de)(de)(de)(de)。SF6氣(qi)(qi)(qi)體具有良好的(de)(de)(de)(de)電(dian)(dian)氣(qi)(qi)(qi)絕緣(yuan)(yuan)(yuan)性(xing)能及優異(yi)的(de)(de)(de)(de)滅(mie)弧性(xing)能,其(qi)耐壓(ya)(ya)(ya)(ya)強(qiang)度為同一(yi)(yi)壓(ya)(ya)(ya)(ya)力下(xia)氮氣(qi)(qi)(qi)的(de)(de)(de)(de)2.5倍,擊(ji)穿電(dian)(dian)壓(ya)(ya)(ya)(ya)的(de)(de)(de)(de)空氣(qi)(qi)(qi)的(de)(de)(de)(de)2.5倍。在(zai)0.25MPa下(xia)與(yu)油的(de)(de)(de)(de)擊(ji)穿電(dian)(dian)壓(ya)(ya)(ya)(ya)相等(deng),在(zai)0.45MPa壓(ya)(ya)(ya)(ya)力下(xia)是(shi)(shi)油的(de)(de)(de)(de)擊(ji)穿電(dian)(dian)壓(ya)(ya)(ya)(ya)的(de)(de)(de)(de)2倍,是(shi)(shi)一(yi)(yi)種優于(yu)油的(de)(de)(de)(de)新一(yi)(yi)代(dai)超高壓(ya)(ya)(ya)(ya)絕緣(yuan)(yuan)(yuan)介質材料。該產品技術要求完全符合《ZBK-41006-89》標(biao)準,它是(shi)(shi)油浸式(shi)輕型試驗變(bian)壓(ya)(ya)(ya)(ya)器的(de)(de)(de)(de)換(huan)代(dai)產品。該產品具有體積(ji)小、重(zhong)量輕、不(bu)受氣(qi)(qi)(qi)候變(bian)化影響(xiang)、電(dian)(dian)暈小、現場搬運(yun)無需靜止可使用,使用壽(shou)命長、免(mian)維(wei)修等(deng)特點。適(shi)用于(yu)電(dian)(dian)力系(xi)統(tong)、工礦企業、科研部門等(deng)對(dui)各種高壓(ya)(ya)(ya)(ya)電(dian)(dian)氣(qi)(qi)(qi)設(she)備、電(dian)(dian)氣(qi)(qi)(qi)元件、絕緣(yuan)(yuan)(yuan)材料進行工頻或直流高壓(ya)(ya)(ya)(ya)下(xia)的(de)(de)(de)(de)絕緣(yuan)(yuan)(yuan)強(qiang)度試驗。
二、產品結構
YDQ系列高壓試驗變壓器采(cai)用單框(kuang)芯(xin)式鐵芯(xin)結(jie)構(gou),初(chu)級繞組繞在鐵芯(xin)上(shang)(shang),高壓繞組在外,這種同軸布置減少了漏磁(ci)通(tong),因而增大(da)了繞組間的耦(ou)合(he)。產品的外殼(ke)為圓(yuan)柱灌式容器結(jie)構(gou),能耐受0.8MPa以上(shang)(shang)壓力。其結(jie)構(gou)見圖1:
三、工(gong)作原理
YDQ系(xi)列高壓(ya)試(shi)(shi)驗變壓(ya)器為單相變壓(ya)器,聯(lian)結組(zu)標號Ⅰ.Ⅰ. 用(yong)工頻220V(10kVA以上為380V)電(dian)源接(jie)入 (為本公(gong)司(si)生產的(de)試(shi)(shi)驗變壓(ya)器配套專用(yong)設備,詳(xiang)細資料請見其具體(ti)使用(yong)說明(ming)書)系(xi)列操(cao)作箱(臺),經操(cao)作箱內自偶調壓(ya)器(50kVA以上調壓(ya)器外(wai)附)調節(jie)至0~200V(或(huo)0~400V)電(dian)壓(ya)輸出至YDQ試(shi)(shi)驗變壓(ya)器的(de)初(chu)級(ji)繞組(zu),根據電(dian)磁(ci)感應(ying)原理,在試(shi)(shi)驗變壓(ya)器高壓(ya)繞組(zu)可獲得試(shi)(shi)驗所需(xu)的(de)高電(dian)壓(ya)。
單臺(tai)YDQ系列交直(zhi)流(liu)高(gao)壓(ya)試驗變(bian)壓(ya)器的(de)工作原理圖(tu)見圖(tu)3,圖(tu)中(zhong)高(gao)壓(ya)套(tao)管中(zhong)裝有高(gao)壓(ya)硅堆,串接在高(gao)壓(ya)回路(lu)中(zhong)作半波(bo)整流(liu),以(yi)獲得直(zhi)流(liu)高(gao)電壓(ya)。當用一(yi)短(duan)路(lu)桿將高(gao)壓(ya)硅堆短(duan)接時,可獲得工頻高(gao)電壓(ya),作為交流(liu)輸(shu)出(chu)狀(zhuang)(zhuang)態;取消(xiao)短(duan)路(lu)桿時,作為直(zhi)流(liu)輸(shu)出(chu)狀(zhuang)(zhuang)態。
圖中:D—短路桿 VD—高壓硅堆
試驗變壓(ya)器高壓(ya)套管中的高壓(ya)硅堆未畫出,其原理(li)與上圖(tu)相同。
三(san)(san)臺(tai)(tai)(tai)試(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)串級(ji)獲得(de)更高(gao)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)的(de)接線原理(li)見(jian)圖4。串級(ji)高(gao)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)試(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)有(you)很大的(de)優越性,因為(wei)(wei)整(zheng)個試(shi)(shi)(shi)驗(yan)(yan)裝(zhuang)置(zhi)由幾臺(tai)(tai)(tai)單(dan)臺(tai)(tai)(tai)試(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)組(zu)成(cheng),單(dan)臺(tai)(tai)(tai)試(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)容(rong)量(liang)小、電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)低、重量(liang)輕,便于運輸(shu)(shu)和安(an)裝(zhuang)。它(ta)既然(ran)可串接成(cheng)高(gao)出幾倍的(de)單(dan)臺(tai)(tai)(tai)試(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)輸(shu)(shu)出電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)組(zu)合使(shi)用(yong),又可分開成(cheng)幾套(tao)單(dan)臺(tai)(tai)(tai)試(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)單(dan)獨使(shi)用(yong)。整(zheng)套(tao)裝(zhuang)置(zhi)投資(zi)小,經(jing)濟實惠。圖5中(zhong),在第(di)(di)(di)**和**級(ji)的(de)每(mei)個單(dan)元試(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)中(zhong)都(dou)有(you)一(yi)個勵(li)磁繞組(zu)A1、C1和A2、C2。在三(san)(san)臺(tai)(tai)(tai)串級(ji)試(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)基本原理(li)中(zhong),低壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)電(dian)(dian)源加在試(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)Ⅰ的(de)初(chu)級(ji)繞組(zu)a1x1上,單(dan)臺(tai)(tai)(tai)試(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)Ⅰ、Ⅱ、Ⅲ的(de)輸(shu)(shu)出電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)都(dou)是(shi)(shi)(shi)V。勵(li)磁繞組(zu)A1、C1給(gei)**級(ji)試(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)Ⅱ的(de)初(chu)級(ji)繞組(zu)供電(dian)(dian);**級(ji)試(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)Ⅱ的(de)勵(li)磁繞組(zu)A2、C2給(gei)第(di)(di)(di)三(san)(san)級(ji)試(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)Ⅲ的(de)初(chu)級(ji)繞組(zu)供電(dian)(dian)。**級(ji)試(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)Ⅱ和第(di)(di)(di)三(san)(san)級(ji)試(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)Ⅲ的(de)箱(xiang)體分別處在對(dui)地為(wei)(wei)1V和2V的(de)高(gao)電(dian)(dian)位上,所(suo)以箱(xiang)體對(dui)地是(shi)(shi)(shi)絕(jue)緣的(de),試(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)Ⅰ的(de)箱(xiang)體是(shi)(shi)(shi)接地的(de)。這樣(yang)第(di)(di)(di)**、**級(ji)、第(di)(di)(di)三(san)(san)級(ji)試(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)對(dui)地的(de)額定(ding)(ding)輸(shu)(shu)出電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)分別為(wei)(wei)1V、2V、3V;其(qi)額定(ding)(ding)容(rong)量(liang)分別為(wei)(wei)3P、2P、1P。
YDQ系列(lie)高(gao)壓試(shi)驗(yan)變壓器做被(bei)試(shi)品的工頻耐(nai)壓試(shi)驗(yan)使用接線原理圖見圖5。
圖中(zhong):R1—限流(liu)電阻 FRC—阻容分壓器 RF—球(qiu)(qiu)間隙保(bao)護(hu)電阻 G—球(qiu)(qiu)間隙 CX—被試品
注:高壓尾必(bi)須可(ke)靠接(jie)地
工(gong)頻耐壓(ya)試(shi)驗(yan)(yan)中限(xian)流(liu)電阻(zu)R1應根(gen)據試(shi)驗(yan)(yan)變壓(ya)器(qi)的(de)額(e)(e)定容(rong)量來選(xuan)擇。如(ru)高壓(ya)側額(e)(e)定輸出電流(liu)在100~300mA時,可(ke)(ke)取0.5~1Ω/V(試(shi)驗(yan)(yan)電壓(ya));高壓(ya)側額(e)(e)定輸出電流(liu)為(wei)1A以(yi)上時,可(ke)(ke)取1Ω/V(試(shi)驗(yan)(yan)電壓(ya))。常用(yong)水電阻(zu)作為(wei)限(xian)流(liu)電阻(zu),管子長(chang)度可(ke)(ke)按150kV/m考(kao)慮(lv),管子粗細(xi)應具有足夠(gou)的(de)熱(re)容(rong)量(水阻(zu)液配(pei)制方法(fa):用(yong)蒸餾水加入適量硫酸銅配(pei)制成(cheng)各種不(bu)同的(de)阻(zu)值)。
球間隙及保(bao)護電(dian)阻(zu):當(dang)電(dian)壓(ya)超(chao)過球間隙整定值時(一般取試驗(yan)電(dian)壓(ya)的(de)110%~120%),球間隙放電(dian),對被試品起到保(bao)護作用。球間隙保(bao)護電(dian)阻(zu)可按(an)1Ω/V(試驗(yan)電(dian)壓(ya))選取。
在工頻耐壓(ya)(ya)(ya)(ya)(ya)(ya)試(shi)(shi)驗(yan)(yan)中,低(di)電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)側(ce)測量(liang)(liang)電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(儀表電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya))不(bu)是非常(chang)準確的(de)(de),其原因(yin)是由于試(shi)(shi)驗(yan)(yan)變壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)存(cun)在著(zhu)漏抗(kang),在這個漏抗(kang)上必然存(cun)在著(zhu)壓(ya)(ya)(ya)(ya)(ya)(ya)降(jiang)或(huo)容(rong)升,使試(shi)(shi)品(pin)(pin)上的(de)(de)電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)低(di)于或(huo)高(gao)(gao)于低(di)壓(ya)(ya)(ya)(ya)(ya)(ya)側(ce)測量(liang)(liang)電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)表上反映出(chu)來的(de)(de)電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)。工頻耐壓(ya)(ya)(ya)(ya)(ya)(ya)試(shi)(shi)驗(yan)(yan)時,被試(shi)(shi)品(pin)(pin)上的(de)(de)電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)高(gao)(gao)于試(shi)(shi)驗(yan)(yan)變壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)的(de)(de)輸(shu)出(chu)電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya),也就(jiu)是所謂容(rong)升現象(xiang)。感應耐壓(ya)(ya)(ya)(ya)(ya)(ya)試(shi)(shi)驗(yan)(yan)時,試(shi)(shi)驗(yan)(yan)變壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)的(de)(de)漏抗(kang)必然存(cun)在著(zhu)壓(ya)(ya)(ya)(ya)(ya)(ya)降(jiang)。為了準確測量(liang)(liang)被試(shi)(shi)品(pin)(pin)上所施加(jia)的(de)(de)電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya),因(yin)此(ci)常(chang)在高(gao)(gao)壓(ya)(ya)(ya)(ya)(ya)(ya)側(ce)接入FRC阻(zu)容(rong)分(fen)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)來測量(liang)(liang)電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(見圖5)。
工頻耐壓試驗操作注意事項(xiang)
1)試驗(yan)人員應做(zuo)好分工(gong),明確相互間聯系方法。并有專門人監護現場**及觀察試品(pin)狀態。
2)被(bei)試(shi)品應(ying)先清(qing)掃干(gan)凈(jing),并**干(gan)燥,以免損壞被(bei)試(shi)品和試(shi)驗帶來的誤差。
3)對于大型試驗,一般都(dou)應先進行空(kong)升(sheng)試驗。即不接試品時升(sheng)壓(ya)至試驗電壓(ya),校對各種表計,調整球間隙。
4)升(sheng)壓(ya)速度不(bu)能(neng)太快,并必須防止(zhi)突(tu)(tu)然加(jia)壓(ya)。例如調壓(ya)器不(bu)在(zai)零(ling)位(wei)時突(tu)(tu)然合閘(zha)(zha)。也不(bu)能(neng)突(tu)(tu)然切斷電(dian)源,一般應在(zai)調壓(ya)器降至零(ling)位(wei)時拉(la)閘(zha)(zha)。
5)當(dang)電壓(ya)(ya)升至(zhi)試(shi)驗電壓(ya)(ya)時,開(kai)始計(ji)時,到(dao)1min后,迅速降壓(ya)(ya)到(dao)1/3試(shi)驗電壓(ya)(ya)以下時,才能拉開(kai)電源。
6)在升壓(ya)(ya)或耐壓(ya)(ya)試驗過程中,如(ru)發(fa)現下列不正(zheng)常(chang)情況時,應立即降壓(ya)(ya),切斷電源(yuan)。停止試驗并查明原因:①電壓(ya)(ya)表指針擺(bai)動很大;②發(fa)現絕(jue)緣燒(shao)焦(jiao)或冒煙(yan);③被試品內有不正(zheng)常(chang)的聲音。
7)耐壓(ya)試(shi)驗前后應(ying)測(ce)量絕緣電阻,檢查(cha)絕緣情況。
試驗(yan)變壓器(qi)在做被(bei)試品的直流(liu)耐壓或泄露試驗(yan)時(shi)接線(xian)原理圖如(ru)圖6。
注:此試驗(yan)應先抽出(chu)短(duan)路(lu)桿“D”,圖6中所示。
圖中:VD—高壓硅(gui)堆 R1—限流電阻(zu) C1—高壓濾波電容 FRC—阻(zu)容分壓器 CX—被試(shi)品 μA—帶保護微安表
泄(xie)露試驗中(zhong)(zhong)限(xian)流電阻(zu)R1選(xuan)擇在額定輸(shu)出電壓時,輸(shu)出端短路(lu)電流不超過高(gao)壓硅(gui)(gui)堆的(de)*大整(zheng)(zheng)流。如電壓硅(gui)(gui)堆的(de)*大整(zheng)(zheng)流電流為(wei)100mA時用于60kV的(de)試驗裝(zhuang)置中(zhong)(zhong),限(xian)流電阻(zu)按R1=60/0.1=600kΩ選(xuan)擇。限(xian)流電阻(zu)還應(ying)具(ju)有足(zu)夠的(de)容量和沿面放電距離。
高壓濾(lv)波電容(rong)C1一般選擇在0.01~0.1μF,當被試品的電容(rong)量(liang)很大時,C1可(ke)省略不用。
泄露試驗的操作及注意事項
1)試驗前應先檢查(cha)被試品是否停電,接地放電,一切對(dui)外連線是否擦干凈。要嚴防將試驗電壓(ya)加到有人工作的(de)部位上(shang)去。
2)接(jie)(jie)好試驗裝(zhuang)置的接(jie)(jie)線后(hou),應復查(cha)無誤(wu)后(hou)才可加(jia)壓。應特別注(zhu)意(yi)檢查(cha)高壓設備及引(yin)線與地、與操作人(ren)員的**距離,被試品的外殼是否(fou)可靠接(jie)(jie)地,要(yao)按(an)**規(gui)程中所(suo)規(gui)定的內容進行試驗。
3)對于(yu)大電(dian)容量設備(bei)應(ying)緩慢升壓,防止被試品的充電(dian)電(dian)流燒壞微安表。必要(yao)時(shi)應(ying)分級加(jia)壓,分別讀取各(ge)級電(dian)壓下微安表的穩(wen)定讀數。
4)試(shi)驗過程(cheng)中,應密切監視被試(shi)品(pin)、試(shi)驗裝置(zhi)、微安(an)表(biao),一旦發(fa)生擊穿、閃爍等異(yi)常現象應立(li)即降壓(ya),切斷電源,并(bing)查(cha)明原因,詳細(xi)記錄。
5)試驗完畢(bi),降壓,切斷(duan)電(dian)源后應(ying)將(jiang)被試品及試驗裝(zhuang)置本身充分放電(dian)。
四、注意事項
1、按照您所進行的(de)試(shi)驗接好工作線路。試(shi)驗變壓(ya)(ya)器(qi)的(de)外(wai)殼(ke)以及(ji)操作系(xi)統(tong)的(de)外(wai)殼(ke)必須可(ke)靠(kao)接地。試(shi)驗變壓(ya)(ya)器(qi)高壓(ya)(ya)繞組(zu)的(de)X端(duan)(高壓(ya)(ya)尾)以及(ji)測量繞組(zu)的(de)F端(duan)必須可(ke)靠(kao)接地。
2、做串級(ji)試(shi)驗(yan)時,**級(ji)、第三級(ji)試(shi)驗(yan)變(bian)壓(ya)器的低壓(ya)繞(rao)組的X端,測量繞(rao)組的F端以及高壓(ya)繞(rao)組的X端(高壓(ya)尾)均接(jie)本級(ji)試(shi)驗(yan)變(bian)壓(ya)器的外殼(ke)。**級(ji)、第三級(ji)試(shi)驗(yan)變(bian)壓(ya)器的外殼(ke)必須通過絕緣支架接(jie)地。
3、接通電(dian)源前,操作系統的(de)調壓(ya)器必(bi)須調到(dao)零位后(hou)方可接通電(dian)源,合閘,開始升(sheng)壓(ya)。
4、從零開始(shi)均勻旋(xuan)轉調(diao)壓(ya)(ya)(ya)(ya)(ya)器(qi)手輪升(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)。升(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)方法(fa)有(you):快(kuai)速升(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)法(fa),即(ji)20s逐級升(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)法(fa);慢(man)速升(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)法(fa),即(ji)60s逐級升(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)法(fa);極慢(man)速升(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)法(fa)供選用。電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)從零開始(shi)按一定(ding)的(de)升(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)方式和速度上(shang)升(sheng)(sheng)到您所需的(de)額定(ding)試(shi)驗電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)的(de)75%后(hou),在以每秒(miao)2%額定(ding)試(shi)驗電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)的(de)速度升(sheng)(sheng)到您所需的(de)額定(ding)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya),并密切(qie)注(zhu)意測量(liang)儀(yi)表(biao)的(de)指示以及被(bei)試(shi)品的(de)情況。升(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)過程中(zhong)(zhong)或(huo)試(shi)驗過程中(zhong)(zhong)如發現測量(liang)儀(yi)表(biao)的(de)指示及被(bei)試(shi)品情況異常,應立即(ji)降壓(ya)(ya)(ya)(ya)(ya),切(qie)斷電(dian)(dian)源,查明(ming)情況。
5、試驗完畢后,應(ying)在數秒內勻(yun)速的(de)將(jiang)調壓器返回至零位,然后切斷(duan)電源。
6、本(ben)產品不得超過額定參(can)數使用。除試(shi)驗必須外,決不允許(xu)全電壓通(tong)電或(huo)斷電。
7、 再升壓(ya)或(huo)耐壓(ya)試驗過程中,如發(fa)現以下(xia)不正常(chang)情況時,應立即(ji)降壓(ya),切斷電源,停止試驗并查明原因(yin)。
⑴電(dian)壓表指針擺動(dong)(或數字跳動(dong))很大
⑵電流表直(zhi)線上升
被試品(pin)內有不正常(chang)的聲(sheng)音
8、圖1中第9項系壓力閥及壓力表,為長期關閉(bi)(bi)狀態。每6個月開閥一次,以檢查SF6壓力,應(ying)不小于0.2MPa(檢查壓力后立即關閉(bi)(bi)閥門),低于0.2MPa時應(ying)加(jia)SF6氣體,以增加(jia)氣絕緣。
9、耐壓實驗前(qian)后應測量被試設備的(de)絕緣(yuan)電阻,檢查(cha)絕緣(yuan)情況。
10、當試驗變壓器長期(qi)不使用時,應放置于通(tong)風、干燥、無(wu)陽光直射的地方。
11、該產品不允(yun)許在高于45℃的溫度下長期(qi)存放(fang)、使用、放(fang)氣(qi)。
12、運輸搬運途中不得重力沖擊。
13、產(chan)品緊固件(jian)及壓力閥(fa)、壓力表不(bu)得(de)擅自松動。
14、使用本產(chan)品(pin)做(zuo)高壓(ya)試驗(yan)時,出熟悉本說明書(shu)外,還(huan)必須嚴格執(zhi)行(xing)國家(jia)有關標準和操作規程。可參照GB311-83《高壓(ya)輸(shu)變設備的絕(jue)緣配(pei)合,高壓(ya)試驗(yan)技術》;《電氣設備預防性試驗(yan)規程》等。
五、試驗變壓(ya)器的容量選(xuan)擇
標稱(cheng)試驗變壓(ya)器容量Pn的(de)確定公(gong)式(shi):Pn=kVn 2ωCt×10-9
式中:
Pn——標稱試驗變壓器容量(kVA)
Vn——試驗變壓(ya)器的額定輸出(chu)高壓(ya)的有效值(kV)
k ——**系數。k≥1,標稱電(dian)壓(ya)(ya)Vn≥1MV時,k=2;標稱電(dian)壓(ya)(ya)較低時,k值可取(qu)高(gao)一些。
Ct——被試(shi)品的電(dian)容(rong)量(pF)
ω——角頻(pin)率,ω=2πf,f——試驗電源的頻(pin)率
被試(shi)設備的電(dian)容量(liang)Ct可由交(jiao)流電(dian)橋測出。Ct的變化很(hen)大,
可由設備的類(lei)型而定。
典型數據如下:
簡(jian)單的棒式或(huo)懸式絕緣子 幾(ji)十微法
簡單的分(fen)級套(tao)管 100~1000pF
電壓互感器 200 ~ 500pF
電力變壓器 < 1000kVA~1000pF
> 1000kVA 1000~10000pF
高壓(ya)電力電纜和油浸紙絕緣(yuan) 250~300pF/m
氣體絕緣(yuan) ~60pF/m
封(feng)閉變電站,SF6氣(qi)體絕(jue)緣(yuan) 100~10000Pf;
對于不(bu)同的(de)試驗電壓Vn,選(xuan)擇不(bu)同的(de)(適當的(de))**系(xi)數k。
以(yi)下(xia)列出不同的Vn所選用(yong)的k值供參考(kao)。
Vn =50~100kV k = 4
Vn =150~300kV k = 3
Vn > 300kV k = 2
一、概述
工頻耐壓(ya)試驗是(shi)鑒(jian)定(ding)電力設(she)備絕(jue)緣強(qiang)度的(de)(de)(de)*嚴格、*有效和*直接(jie)的(de)(de)(de)方法。它能檢查出那些(xie)危(wei)險性(xing)較(jiao)大的(de)(de)(de)集中缺陷,對判斷電力設(she)備能否(fou)繼續參加運行具(ju)有決定(ding)性(xing)作用,是(shi)保證設(she)備絕(jue)緣水平、避免發(fa)生絕(jue)緣事故的(de)(de)(de)重要手段。
本裝置(zhi)是根(gen)據(ju)國家*新電(dian)力行業標準而(er)設計的(de)(de)(de)、性能先進(jin)的(de)(de)(de)耐壓(ya)試驗設備,用(yong)于對各種電(dian)器產(chan)品(pin)、電(dian)氣元件(jian)、絕(jue)緣(yuan)材料等(deng)進(jin)行規(gui)定電(dian)壓(ya)下(xia)的(de)(de)(de)絕(jue)緣(yuan)強度試驗,以考核產(chan)品(pin)的(de)(de)(de)絕(jue)緣(yuan)水平,發現被試品(pin)的(de)(de)(de)絕(jue)緣(yuan)缺陷,衡(heng)量(liang)過(guo)電(dian)壓(ya)的(de)(de)(de)能力。
二、產品(pin)特點
監視功能:高壓(ya)電(dian)壓(ya) 低(di)壓(ya)電(dian)流 零(ling)位(wei)指示(shi)(shi) 電(dian)源指示(shi)(shi) 工作指示(shi)(shi) 計(ji)時指示(shi)(shi)
保護功能(neng):過流保護、零位啟動保護、聲光(guang)語言報警提醒(xing)
采用新型時間繼電器,計時范圍更廣(1S~99H)
采用新型電流繼電器,更**、更可靠,確保人身及設備**。
試驗變壓(ya)器高壓(ya)線(xian)圈為圓筒(tong)多(duo)層(ceng)塔式(shi),由上(shang)等聚酯(zhi)漆(qi)包線(xian)及(ji)高耐壓(ya)值絕緣材料(liao)繞制而成。
試驗變壓(ya)器(5kVA以上(shang))裝有(you)可(ke)移動(dong)的鐵(tie)輪。具(ju)有(you)重(zhong)量輕(qing)、體積小、移動(dong)方(fang)便、性能優越(yue)等特點。
三、設備組成
1、選型配置
標準配置(zhi)
|
□ 分體式
|
操(cao)作部分:
□箱式(不大于5kVA) / □臺式
容量(liang): kVA(小(xiao)于200kVA)
輸入:□AC220V / □AC380V
|
試驗變壓(ya)器(qi):
□交流 / □交直流
□油變(bian) / □干(gan)變(bian) / □氣變(bian)
容量: kVA(小于200kVA)
輸出:AC kV(小(xiao)于300kVA)
|
□ 一體式(shi)
|
□箱(xiang)式(shi)(不大于20kV) / □臺式(shi)(不大于30kV)
容量: kVA(小于300kVA)
輸入:□AC220V / □AC380V 輸出:AC kV(不大于(yu)30kV)
|
客(ke)戶選配
|
□標準高壓分(fen)壓器(qi)
|
□保護球(qiu)隙
|
□直流(liu)微安(an)表
|
□放**
|
□保護水阻
|
□高壓(ya)濾(lv)波電(dian)容
|
其它(ta):
|
2、對應實物
四、技術(shu)指標
1、使用條件(jian):
(1)工作場所應無嚴重影(ying)響絕緣的(de)氣體、蒸汽(qi)、化(hua)學性塵埃及其它爆炸性和腐蝕性介質。
(2)環境溫度 -20~+50℃
(3)環境濕(shi)度 ≤85% RH(無凝(ning)結水)
2、控(kong)制箱(臺(tai))參(can)數:(常規(gui)參(can)數見下表)
規格(ge)
|
容量(liang)
|
輸 入 電(dian) 源
|
輸 出 電(dian) 壓
|
重量(liang)(kg)
|
相數
|
(V)
|
(A)
|
(V)
|
(A)
|
2/220
|
2
|
1
|
220
|
10
|
0-250
|
8
|
14
|
3/220
|
3
|
1
|
220
|
15
|
0-250
|
12
|
16
|
5/220
|
5
|
1
|
220
|
25
|
0-250
|
20
|
18
|
10/220
|
10
|
1
|
220
|
50
|
0-250
|
40
|
80
|
15/380
|
15
|
2
|
380
|
37.5
|
0-430
|
34.8
|
90
|
20/380
|
20
|
2
|
380
|
50
|
0-430
|
46.5
|
100
|
25/380
|
25
|
2
|
380
|
62.5
|
0-430
|
58.1
|
120
|
30/380
|
30
|
2
|
380
|
75
|
0-430
|
69.7
|
140
|
50/380
|
50
|
2
|
380
|
125
|
0-430
|
116.2
|
160
|
100/380
|
100
|
2
|
380
|
250
|
0-430
|
232.5
|
250
|
說(shuo)明:如有特殊參數(shu)要求(qiu),可(ke)按用戶(hu)的技術參數(shu)進(jin)行設計制作。
3、試(shi)驗變壓器參(can)數(shu)(shu):(常規參(can)數(shu)(shu)見下(xia)表)
規格
|
容(rong)量
kVA
|
低壓側
|
高壓側
|
高(gao)壓側(ce)(交直(zhi)流變(bian)壓器)
|
測量變比
|
60分鐘溫(wen)升℃
|
阻抗電壓(ya)%
|
空載電流
%
|
質量(liang)
kg
|
電壓
V
|
電流
A
|
交流輸出
|
直(zhi)流輸(shu)出(chu)
|
電壓kV
|
電流(liu)
|
電壓kV
|
電(dian)流
|
1.5/50
|
1.5
|
200
|
7.5
|
50
|
30
|
70
|
21.4
|
500
|
50
|
10
|
<4
|
19.5
|
3/50
|
3
|
200
|
15
|
50
|
60
|
70
|
42.9
|
500
|
50
|
10
|
<4
|
27
|
5/50
|
5
|
200
|
25
|
50
|
100
|
70
|
71.4
|
500
|
50
|
10
|
<4
|
52
|
10/50
|
10
|
200
|
50
|
50
|
200
|
70
|
142.9
|
500
|
50
|
10
|
<4
|
80
|
15/50
|
15
|
400
|
37.5
|
50
|
300
|
70
|
214.3
|
500
|
50
|
8
|
<4
|
120
|
20/50
|
20
|
400
|
50
|
50
|
400
|
70
|
285.7
|
500
|
50
|
8
|
<4
|
140
|
30/50
|
30
|
400
|
75
|
50
|
600
|
70
|
428.6
|
500
|
50
|
8
|
<4
|
155
|
50/50
|
50
|
400
|
125
|
50
|
1000
|
70
|
714.3
|
500
|
50
|
8
|
<4
|
184
|
10/100
|
10
|
200
|
50
|
100
|
100
|
140
|
71.4
|
1000
|
50
|
10
|
<4
|
135
|
15/100
|
15
|
400
|
37.5
|
100
|
150
|
140
|
107.1
|
1000
|
50
|
8
|
<4
|
150
|
20/100
|
20
|
400
|
50
|
100
|
200
|
140
|
142.9
|
1000
|
50
|
8
|
<4
|
215
|
30/100
|
30
|
400
|
75
|
100
|
300
|
140
|
214.3
|
1000
|
50
|
8
|
<4
|
250
|
50/100
|
50
|
400
|
125
|
100
|
500
|
140
|
357.1
|
1000
|
50
|
8
|
<4
|
290
|
10/150
|
10
|
200
|
50
|
100
|
66.7
|
140
|
47.6
|
1500
|
50
|
10
|
<4
|
180
|
15/150
|
15
|
400
|
37.5
|
150
|
100
|
210
|
71.4
|
1500
|
50
|
8
|
<4
|
200
|
20/150
|
30
|
400
|
50
|
150
|
133.3
|
210
|
95.2
|
1500
|
50
|
8
|
<4
|
220
|
30/150
|
30
|
400
|
75
|
150
|
200
|
210
|
142.9
|
1500
|
50
|
8
|
<4
|
280
|
50/150
|
50
|
400
|
125
|
150
|
333.3
|
210
|
238.1
|
1500
|
50
|
8
|
<4
|
340
|
說(shuo)明:如(ru)有特殊參數要求,可按用戶的(de)技術參數進行設計制作。
上表(biao)的重量以油浸式(shi)試驗變(bian)壓器為例,干式(shi)試驗變(bian)壓器和充氣式(shi)試驗變(bian)壓器稍有(you)不同。
五、接線及工作原理(li)
1、調壓(ya)部(bu)分接線及原理
調(diao)壓(ya)部(bu)(bu)分(fen)由(you)(you)控(kong)制部(bu)(bu)分(fen)和試驗變壓(ya)器(qi)組成(cheng)(cheng)。控(kong)制部(bu)(bu)分(fen)是由(you)(you)接觸式(shi)調(diao)壓(ya)器(qi)及其(qi)控(kong)制、保護、測量、信號電(dian)路(lu)組成(cheng)(cheng)。試驗變壓(ya)器(qi)由(you)(you)低壓(ya)繞組、高壓(ya)繞組、儀表繞組三部(bu)(bu)分(fen)組成(cheng)(cheng)。
試驗(yan)變(bian)(bian)(bian)(bian)(bian)壓(ya)器(qi)為交直流兩用時,試驗(yan)變(bian)(bian)(bian)(bian)(bian)壓(ya)器(qi)配置(zhi)了高(gao)壓(ya)硅堆(油變(bian)(bian)(bian)(bian)(bian)、氣變(bian)(bian)(bian)(bian)(bian)為內置(zhi),干(gan)變(bian)(bian)(bian)(bian)(bian)為外(wai)(wai)置(zhi)),高(gao)壓(ya)可輸(shu)出交流和(he)直流。輸(shu)出交流時,要(yao)(yao)求接入短路(lu)桿(油變(bian)(bian)(bian)(bian)(bian)、氣變(bian)(bian)(bian)(bian)(bian))或去掉外(wai)(wai)置(zhi)硅堆(干(gan)變(bian)(bian)(bian)(bian)(bian));輸(shu)出直流時,要(yao)(yao)求擰出短路(lu)桿(油變(bian)(bian)(bian)(bian)(bian)、氣變(bian)(bian)(bian)(bian)(bian))或加(jia)上外(wai)(wai)置(zhi)硅堆(干(gan)變(bian)(bian)(bian)(bian)(bian))
通(tong)過接入工頻電源,調節調壓器,以獲(huo)得所需要的試(shi)驗(yan)高壓電壓值。其工作原理(li)見圖1:
2、試驗部分接線及原(yuan)理
做耐(nai)壓(ya)試(shi)驗時,控制(zhi)部分(fen)、變壓(ya)器的接地端及(ji)高壓(ya)尾必(bi)須可靠接地。有條(tiao)件(jian)的情(qing)況下,做工頻(pin)耐(nai)壓(ya)試(shi)驗請加上限流電(dian)阻、標準高壓(ya)分(fen)壓(ya)器、球隙(xi)(xi)保(bao)護電(dian)阻及(ji)保(bao)護球隙(xi)(xi),如圖(tu)3。
做直(zhi)流(liu)耐壓(ya)(ya)試驗請另外(wai)加上微安表,微安表必須接在(zai)(zai)硅(gui)堆和被試器(qi)(qi)之間(jian),油變或氣變一(yi)般擰(ning)在(zai)(zai)高壓(ya)(ya)頭上面(mian)(要求擰(ning)出短路(lu)桿),干(gan)變擰(ning)在(zai)(zai)外(wai)置硅(gui)堆上面(mian);為了(le)更準確顯示高壓(ya)(ya)直(zhi)流(liu)泄漏電流(liu),請將分壓(ya)(ya)器(qi)(qi)的高壓(ya)(ya)線接在(zai)(zai)微安表和硅(gui)堆之間(jian),(油變、氣變)如圖4,(干(gan)變)如圖5。
耐壓試(shi)驗(yan)中限(xian)流(liu)電(dian)(dian)阻R1應(ying)根據試(shi)驗(yan)變壓器的(de)(de)額定容量來選擇。如高(gao)壓側額定輸(shu)出電(dian)(dian)流(liu)在100~300mA時,可(ke)取(qu)0.5~1Ω/V(試(shi)驗(yan)電(dian)(dian)壓);高(gao)壓側額定輸(shu)出電(dian)(dian)流(liu)為(wei)1A以上(shang)時,可(ke)取(qu)1Ω/V(試(shi)驗(yan)電(dian)(dian)壓)。常用水電(dian)(dian)阻作為(wei)限(xian)流(liu)電(dian)(dian)阻,管子長度可(ke)按150kV/m考慮,管子粗細應(ying)具有足夠的(de)(de)熱容量(水阻液(ye)配制(zhi)方法(fa):用蒸餾水加入適量硫酸(suan)銅配制(zhi)成(cheng)各種不同(tong)的(de)(de)阻值)。
球間隙(xi)及(ji)保護(hu)(hu)電(dian)阻(zu):當電(dian)壓(ya)(ya)超過(guo)球間隙(xi)整定值時(一般取試(shi)驗電(dian)壓(ya)(ya)的110%~120%),球間隙(xi)放電(dian),對被試(shi)品起到保護(hu)(hu)作用。球間隙(xi)保護(hu)(hu)電(dian)阻(zu)可按1Ω/V(試(shi)驗電(dian)壓(ya)(ya))選取。
在(zai)工頻耐(nai)壓(ya)(ya)(ya)(ya)(ya)試(shi)(shi)(shi)驗(yan)(yan)(yan)中,低(di)電(dian)壓(ya)(ya)(ya)(ya)(ya)側(ce)測量(liang)電(dian)壓(ya)(ya)(ya)(ya)(ya)(儀(yi)表(biao)(biao)電(dian)壓(ya)(ya)(ya)(ya)(ya))不(bu)是非(fei)常準(zhun)確的,其原因是由于(yu)(yu)(yu)試(shi)(shi)(shi)驗(yan)(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)存在(zai)著(zhu)漏抗,在(zai)這(zhe)個漏抗上(shang)(shang)(shang)必(bi)然存在(zai)著(zhu)壓(ya)(ya)(ya)(ya)(ya)降或容升(sheng),使試(shi)(shi)(shi)品上(shang)(shang)(shang)的電(dian)壓(ya)(ya)(ya)(ya)(ya)低(di)于(yu)(yu)(yu)或高(gao)于(yu)(yu)(yu)低(di)壓(ya)(ya)(ya)(ya)(ya)側(ce)測量(liang)電(dian)壓(ya)(ya)(ya)(ya)(ya)表(biao)(biao)上(shang)(shang)(shang)反(fan)映出來的電(dian)壓(ya)(ya)(ya)(ya)(ya)。工頻耐(nai)壓(ya)(ya)(ya)(ya)(ya)試(shi)(shi)(shi)驗(yan)(yan)(yan)時,被(bei)(bei)試(shi)(shi)(shi)品上(shang)(shang)(shang)的電(dian)壓(ya)(ya)(ya)(ya)(ya)高(gao)于(yu)(yu)(yu)試(shi)(shi)(shi)驗(yan)(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)的輸出電(dian)壓(ya)(ya)(ya)(ya)(ya),也就是所謂(wei)容升(sheng)現(xian)象。感應耐(nai)壓(ya)(ya)(ya)(ya)(ya)試(shi)(shi)(shi)驗(yan)(yan)(yan)時,試(shi)(shi)(shi)驗(yan)(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)的漏抗必(bi)然存在(zai)著(zhu)壓(ya)(ya)(ya)(ya)(ya)降。為了準(zhun)確測量(liang)被(bei)(bei)試(shi)(shi)(shi)品上(shang)(shang)(shang)所施(shi)加的電(dian)壓(ya)(ya)(ya)(ya)(ya),因此(ci)常在(zai)高(gao)壓(ya)(ya)(ya)(ya)(ya)側(ce)接入標準(zhun)高(gao)壓(ya)(ya)(ya)(ya)(ya)分壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)來測量(liang)電(dian)壓(ya)(ya)(ya)(ya)(ya)。
五、面(mian)板(ban)結構說明
1、操作(zuo)箱面(mian)板(ban)
控制箱(xiang)(xiang)為箱(xiang)(xiang)式鋁合金(jin)結構(gou),面(mian)板采用拉(la)絲鋁合金(jin)工(gong)藝,所有(you)電器元(yuan)件(jian)均裝在骨架上(shang),便于安裝和維修。面(mian)板元(yuan)件(jian)布(bu)置(zhi)如下:
2、操作臺面板(ban)
操作臺(tai)為(wei)臺(tai)式結(jie)構,殼體為(wei)冷扎(zha)鋼(gang)板(ban)結(jie)構,面(mian)板(ban)采用鋁合金(jin)拉絲工藝,面(mian)板(ban)元件布置如下:
六(liu)、操作(zuo)指南
本裝(zhuang)置(zhi)在(zai)操(cao)作之前應根據不同被試品的容量(liang)、電壓等級,先計算好*大工作電流,并調(diao)整電流保護器。其(qi)試驗接線(xian)應參(can)考本說明(ming)書中圖1、圖2、圖3、圖4、圖5,必須(xu)可靠接地。
1、操作要點
(1)試(shi)(shi)驗前,應(ying)了(le)解被試(shi)(shi)品的(de)試(shi)(shi)驗電壓(ya),同(tong)時了(le)解被試(shi)(shi)品的(de)其(qi)他試(shi)(shi)驗項目及以前的(de)試(shi)(shi)驗結(jie)果。若被試(shi)(shi)品有缺陷或異常,應(ying)在(zai)消除后(hou)再進行耐壓(ya)試(shi)(shi)驗。
(2)試(shi)驗現(xian)場應圍好遮攔或圍繩,掛好標示牌,并派(pai)專人(ren)監護。
(3)試驗前,被(bei)試品表面應(ying)(ying)擦(ca)拭干凈(jing),將被(bei)試品的外殼和(he)非(fei)被(bei)試繞組可靠(kao)接地。被(bei)試品為新沖(chong)油(you)設備(bei)(bei)時,應(ying)(ying)按《規程》規定使油(you)靜(jing)止一定時間再升壓,對110kV及以(yi)下的充油(you)電力設備(bei)(bei),在注滿油(you)后靜(jing)置時間應(ying)(ying)不(bu)少于24小時,對220kV及330kV的充油(you)電力設備(bei)(bei),靜(jing)置時間應(ying)(ying)不(bu)少于48小時。
(4)接好試驗接線后(hou),應(ying)由有經驗的人(ren)員(yuan)檢查,確認無(wu)誤后(hou)方可(ke)升壓(ya)。
(5)升(sheng)(sheng)壓(ya)(ya)前,首(shou)先檢查調(diao)壓(ya)(ya)器是否在(zai)零位。調(diao)壓(ya)(ya)器在(zai)零位方可升(sheng)(sheng)壓(ya)(ya)。
(6)升壓(ya)(ya)過程中不(bu)僅要監(jian)視電(dian)壓(ya)(ya)表的變(bian)化,還應監(jian)視電(dian)流表的變(bian)化,以(yi)及(ji)被試(shi)品電(dian)流的變(bian)化。升壓(ya)(ya)時(shi)(shi)(shi)要均(jun)(jun)勻(yun)升壓(ya)(ya),不(bu)能太(tai)快。升至規定試(shi)驗電(dian)壓(ya)(ya)時(shi)(shi)(shi),開始計算時(shi)(shi)(shi)間,時(shi)(shi)(shi)間到后,緩慢均(jun)(jun)勻(yun)降下電(dian)壓(ya)(ya)。絕(jue)不(bu)允(yun)許不(bu)降壓(ya)(ya)就先跳開電(dian)源開關。
(7)試驗中發現(xian)表針擺動或被試品有異常聲響、冒煙等應立即降下電(dian)壓,拉開電(dian)源,在(zai)高壓側(ce)掛(gua)上(shang)接地線后,再查明(ming)原因。
(8)耐壓試驗前后均應(ying)測量被試品的絕緣(yuan)電阻。
2、操作步驟
(1) 按試驗(yan)要求將控(kong)制(zhi)部分、試驗(yan)變壓器、被(bei)試品正確(que)接好線,必須可靠接地,請(qing)參考圖1、圖2、圖3、圖4、圖5。
(2) 根(gen)據試驗的要求,整(zheng)定(ding)“時(shi)間繼(ji)電器(qi)”及(ji)“過流繼(ji)電器(qi)”。
A 時間繼(ji)電器(qi)設置:
T1,T2,T3,T4設置0~9任意數字(zi),T可設置為(wei)H(小時),M(分鐘),S(秒)。
根據試(shi)驗要(yao)求,在1S~99H內(nei)可以(yi)任(ren)意設置定(ding)時時間。
B 過流繼電(dian)器設置:
過(guo)(guo)流動作(zuo)設定值(zhi)(zhi)=過(guo)(guo)流繼電(dian)器(qi)刻度盤讀數×測量變(bian)比×K,其(qi)中K為(wei)(wei)電(dian)流倍率/切(qie)除(chu)開關(guan)的狀態值(zhi)(zhi),分(fen)別為(wei)(wei)X1,X2,OFF,電(dian)流倍率/切(qie)除(chu)開關(guan)處(chu)于×1,×2位(wei)置(zhi)時,K值(zhi)(zhi)分(fen)別為(wei)(wei)1、2,切(qie)換為(wei)(wei)OFF擋時,K值(zhi)(zhi)為(wei)(wei)+∞。(注:不要(yao)使用(yong)OFF檔,因為(wei)(wei)會使變(bian)壓器(qi)失去過(guo)(guo)流保護功能而(er)導致設備損壞。測量變(bian)比為(wei)(wei)電(dian)流互感器(qi)的變(bian)比,沒有電(dian)流互感器(qi)時為(wei)(wei)1)。
(3) 接入電源(yuan),此時,“電源(yuan)燈”亮,表(biao)示外部電源(yuan)已(yi)引入。如“零位(wei)(wei)(wei)燈”亮,表(biao)示調(diao)壓(ya)(ya)器在零位(wei)(wei)(wei)。如“零位(wei)(wei)(wei)燈”不亮,應(ying)逆(ni)時針旋轉調(diao)節調(diao)壓(ya)(ya)器手柄至(zhi)“零位(wei)(wei)(wei)燈”亮,表(biao)示可進行調(diao)壓(ya)(ya)操作。
(4)按(an)(an)“啟(qi)動按(an)(an)鈕”。此時,“送電(dian)燈”,“電(dian)源燈”和“零(ling)位(wei)燈”亮(liang);進入送電(dian)狀態。
(5)以2kV/S勻速順時(shi)針旋轉調(diao)壓器手(shou)柄至(zhi)被(bei)試(shi)品(pin)規定的耐(nai)壓值,并密(mi)切注(zhu)視電流(liu)表(直流(liu)耐(nai)壓試(shi)驗時(shi),同時(shi)密(mi)切注(zhu)視直流(liu)微(wei)安(an)表)。此時(shi),“電源(yuan)燈”,“工作燈”亮;“零位燈”滅。
(6)根據試驗(yan)啟動“計(ji)時按鈕”,計(ji)時開(kai)始,并注意(yi)被試品的情況。
(7)當耐(nai)壓計時(shi)到時(shi),操作臺自(zi)動聲光報警。應立(li)即逆時(shi)針旋轉(zhuan)調壓器手(shou)柄至零位,按下(xia)停止按鈕和解除計時(shi)按鈕自(zi)鎖狀態。此時(shi)“電源燈(deng)”, “零位燈(deng)”亮,“工作燈(deng)”滅。試驗即告完畢(bi)
(8)拔掉電源,拆除接線(xian),試驗結束。
(9)在升壓或耐(nai)壓過(guo)程中(zhong),如發生短路、閃絡、擊穿過(guo)流時,過(guo)流繼電(dian)器動作,切斷(duan)主(zhu)回路。此時應將調壓器逆時針旋轉至零位,切斷(duan)電(dian)源,并(bing)查明原(yuan)因,并(bing)作詳(xiang)細記錄。
(10)試(shi)驗(yan)(yan)完畢,降(jiang)壓,切(qie)斷電源后應(ying)用放(fang)**將被試(shi)品及試(shi)驗(yan)(yan)裝置(zhi)本身充分放(fang)電。
七、產品維護
1、開箱(xiang)驗(yan)收時,應檢查主控回路接線是(shi)(shi)否(fou)松動,調壓器電刷是(shi)(shi)否(fou)接觸良好;
2、長期不用(yong)時,使(shi)用(yong)前應用(yong)500V兆歐(ou)表測(ce)量絕(jue)緣電阻,其阻值不低于(yu)0.5MΩ;
3、電(dian)(dian)源(yuan)電(dian)(dian)壓應符合(he)控(kong)制箱(臺)銘(ming)牌上(shang)的輸(shu)入電(dian)(dian)壓值;
4、本裝置設有(you)過(guo)電(dian)流(liu)保(bao)護,出廠已調整為額(e)定(ding)電(dian)流(liu)的50%。用于小負(fu)載(zai)時,應根據被(bei)試品的額(e)定(ding)容量電(dian)流(liu)重新(xin)設定(ding);
5、使用完畢后,應關好(hao)控制(zhi)箱(臺)門,以保持控制(zhi)箱(臺)內部清潔。
八(ba)、注(zhu)意(yi)事(shi)項(xiang)
1、按照您(nin)所進行的(de)(de)試驗接好工作線路。試驗變壓(ya)器的(de)(de)外(wai)殼(ke)(ke)以(yi)及操作系(xi)統的(de)(de)外(wai)殼(ke)(ke)必須可靠接地(di)(di)。試驗變壓(ya)器的(de)(de)高(gao)壓(ya)繞組的(de)(de)X端(高(gao)壓(ya)尾)以(yi)及測量繞組的(de)(de)F端必須可靠接地(di)(di)。
2、做(zuo)串(chuan)級(ji)試(shi)(shi)驗(yan)(yan)時,**級(ji)、第三級(ji)試(shi)(shi)驗(yan)(yan)變(bian)壓(ya)器(qi)的低壓(ya)繞(rao)組成X端(duan),測量(liang)繞(rao)組的F端(duan)以及(ji)高壓(ya)繞(rao)組的X端(duan)(高壓(ya)端(duan))均接本級(ji)試(shi)(shi)驗(yan)(yan)變(bian)壓(ya)器(qi)具外殼(ke)(ke)。**級(ji)、第三級(ji)試(shi)(shi)驗(yan)(yan)變(bian)壓(ya)器(qi)的外殼(ke)(ke)必須通過(guo)絕緣支架(jia)接地(di)。
3、接通電(dian)(dian)源(yuan)前(qian),操作(zuo)系統(tong)的(de)調(diao)壓(ya)器(qi)必須調(diao)到零(ling)位(wei)后(hou)方(fang)可接通電(dian)(dian)源(yuan),合(he)閘,開始(shi)升(sheng)(sheng)(sheng)壓(ya)。從零(ling)開始(shi)勻速旋轉調(diao)壓(ya)器(qi)手輪升(sheng)(sheng)(sheng)壓(ya)。升(sheng)(sheng)(sheng)壓(ya)方(fang)式有:快速升(sheng)(sheng)(sheng)壓(ya)法(fa)(fa)(fa),即(ji)20s逐(zhu)級升(sheng)(sheng)(sheng)壓(ya)法(fa)(fa)(fa);慢速升(sheng)(sheng)(sheng)壓(ya)法(fa)(fa)(fa),即(ji)60s逐(zhu)級升(sheng)(sheng)(sheng)壓(ya)法(fa)(fa)(fa);極慢速升(sheng)(sheng)(sheng)壓(ya)法(fa)(fa)(fa)供選用(yong)。電(dian)(dian)壓(ya)從零(ling)開始(shi)按一(yi)定的(de)升(sheng)(sheng)(sheng)壓(ya)方(fang)式和速度(du)上升(sheng)(sheng)(sheng)到您所需的(de)額(e)定試(shi)(shi)(shi)驗(yan)(yan)電(dian)(dian)壓(ya)的(de)75%后(hou),再以每秒2%額(e)定試(shi)(shi)(shi)驗(yan)(yan)電(dian)(dian)壓(ya)的(de)速度(du)升(sheng)(sheng)(sheng)到您所需的(de)試(shi)(shi)(shi)驗(yan)(yan)電(dian)(dian)壓(ya),并密切注意測量儀表的(de)及被(bei)(bei)試(shi)(shi)(shi)品的(de)情況。升(sheng)(sheng)(sheng)壓(ya)過程(cheng)中或試(shi)(shi)(shi)驗(yan)(yan)過程(cheng)中如發現(xian)測量儀表的(de)指(zhi)示及被(bei)(bei)試(shi)(shi)(shi)品情況異常,應立即(ji)降壓(ya),切斷(duan)電(dian)(dian)源(yuan),查明情況。
4、試驗完(wan)畢(bi)后,應在數(shu)秒內(nei)勻速的將調壓器返回至零位,然后切斷電源。本產品不得超過額定參數(shu)使(shi)用。
5、使(shi)用本產品(pin)做高壓(ya)(ya)試(shi)驗時,除(chu)熟悉本說明書外,還必須嚴(yan)格執行國家(jia)有關(guan)標準和操(cao)作(zuo)規程。可參照GB311.1 – 97《高壓(ya)(ya)輸變設(she)備的絕緣(yuan)配合,高壓(ya)(ya)試(shi)驗技術(shu)》;《電氣設(she)備預防性(xing)試(shi)驗規程》等
一(yi)、概述(shu)
智(zhi)能(neng)耐壓(ya)試驗裝(zhuang)置是根據(ju)國家*新(xin)電(dian)力行(xing)業標(biao)準而設計的、性能(neng)先進(jin)的智(zhi)能(neng)型耐壓(ya)試驗設備,用于對各種(zhong)電(dian)器產(chan)品(pin)、電(dian)氣元件、絕緣(yuan)材料等進(jin)行(xing)規定(ding)電(dian)壓(ya)下的絕緣(yuan)強度試驗,以考核產(chan)品(pin)的絕緣(yuan)水平,發(fa)現(xian)被試品(pin)的絕緣(yuan)缺陷,衡量過電(dian)壓(ya)的能(neng)力。廣泛應用于電(dian)工制(zhi)造部門、電(dian)力運行(xing)部門、科(ke)研(yan)單位和高等院(yuan)校(xiao)。
二、產品特點
1. 320×240液晶顯示(shi)器(qi)、高速熱(re)敏打印機(ji)。
2. 高(gao)壓(ya)電壓(ya)、高(gao)壓(ya)電流(liu)(liu)、低壓(ya)電壓(ya)、低壓(ya)電流(liu)(liu)4路測量方式,高(gao)精度傳感器和高(gao)性(xing)能14位AD采集芯片(pian)。
3. 人機(ji)對話全鍵(jian)盤操作(zuo)方式(shi),智(zhi)能化工(gong)作(zuo)全過(guo)程,任選自動(dong)方式(shi)和(he)手動(dong)方式(shi)。
4. 實(shi)時顯示高壓(ya)(ya)(ya)電壓(ya)(ya)(ya)、高壓(ya)(ya)(ya)電流(liu)、低(di)壓(ya)(ya)(ya)電壓(ya)(ya)(ya)、低(di)壓(ya)(ya)(ya)電流(liu),時間(jian)及耐壓(ya)(ya)(ya)結果,顯示直觀(guan)明了(le)。
5. 完(wan)善(shan)的過壓(ya)(ya)、過流保護,任意設定輸出電(dian)壓(ya)(ya)、高壓(ya)(ya)電(dian)流上(shang)限、低壓(ya)(ya)電(dian)流上(shang)限和計時時間。
6. 具有回零(ling)檢測功能,回零(ling)確定后才可(ke)進行試驗,**可(ke)靠。
7. 具有絕(jue)緣電阻(zu)測試功能(neng),直接反映被試品絕(jue)緣強度。
8. 逼近式調壓算法,到達設定電壓后(hou)自動耐壓計時(shi),計時(shi)結束后(hou)自動降壓回零。
9. 超過設定高壓(ya)電流(liu)或(huo)低壓(ya)電流(liu)時自動切斷(duan)電壓(ya)輸出,降壓(ya)回零,并發生(sheng)聲光報警。
10. 精良的軟硬件抗(kang)干擾設計,多(duo)種抗(kang)干擾手段,適(shi)應惡劣電磁環境(jing)。
11. 自(zi)動錯(cuo)誤診(zhen)斷(duan),易于發現(xian)和解決(jue)問題。
12. 可選配(pei)無線遙控(kong)控(kong)制功能、遠程通信、門聯(lian)鎖警鈴(ling)、外接分壓(ya)器校驗接口(kou)等。
三(san)、設備組成
1、選型配置
標準(zhun)配(pei)置(zhi)
|
□ 分體式
|
操(cao)作部分:
□箱式(shi)(不(bu)大于(yu)5kVA) / □臺式(shi)
容(rong)量: kVA(小于(yu)200kVA)
輸入:□AC220V / □AC380V
|
試驗變壓器:
□交(jiao)流 / □交(jiao)直流
□油變 / □干變 / □氣(qi)變
容量: kVA(小于200kVA)
輸出:AC kV(小于300kVA)
|
□ 一體式
|
□箱式(shi)(不大于20kV) / □臺式(shi)(不大于30kV)
容(rong)量(liang): kVA(小于300kVA)
輸(shu)(shu)入:□AC220V / □AC380V 輸(shu)(shu)出:AC kV(不大于30kV)
|
客戶選配
|
□標準高壓(ya)分壓(ya)器(qi)
|
□保(bao)護球隙
|
□直流(liu)微安表
|
□放**
|
□保護水阻
|
□高壓濾波電容
|
其它:
|
2、對應實(shi)物(wu)
四、技術指標
1、使用條件:
(1)工作場所應無嚴重影(ying)響絕緣的氣體、蒸汽、化學性塵(chen)埃(ai)及其它爆炸性和腐蝕性介(jie)質。
(2)環(huan)境(jing)溫(wen)度 -20~+50℃
(3)環境濕度 ≤85% RH(無凝結水)
2、控制箱(臺)參(can)數(shu):(常規(gui)參(can)數(shu)見下表)
(1)計時范圍:0-999S
(3)電壓(ya)精度 ≤1.5% ±1個字(F.S)
(4)電流精度 ≤1.5% ±1個字(F.S)
規格
|
容量
|
輸 入 電 源
|
輸 出 電 壓(ya)
|
重(zhong)量(kg)
|
相數
|
(V)
|
(A)
|
(V)
|
(A)
|
2/220
|
2
|
1
|
220
|
10
|
0-250
|
8
|
14
|
3/220
|
3
|
1
|
220
|
15
|
0-250
|
12
|
16
|
5/220
|
5
|
1
|
220
|
25
|
0-250
|
20
|
18
|
10/220
|
10
|
1
|
220
|
50
|
0-250
|
40
|
80
|
15/380
|
15
|
2
|
380
|
37.5
|
0-430
|
34.8
|
90
|
20/380
|
20
|
2
|
380
|
50
|
0-430
|
46.5
|
100
|
25/380
|
25
|
2
|
380
|
62.5
|
0-430
|
58.1
|
120
|
30/380
|
30
|
2
|
380
|
75
|
0-430
|
69.7
|
140
|
50/380
|
50
|
2
|
380
|
125
|
0-430
|
116.2
|
160
|
100/380
|
100
|
2
|
380
|
250
|
0-430
|
232.5
|
250
|
說明:如有特殊參數(shu)要求,可按用(yong)戶的技術參數(shu)進(jin)行設計(ji)制作。
3、試驗變(bian)壓器參(can)數:(常規參(can)數見(jian)下表)
規格
|
容量(liang)
kVA
|
低壓側(ce)
|
高壓(ya)側
|
高(gao)壓(ya)側(ce)(交直(zhi)流(liu)變壓(ya)器(qi))
|
測量變比
|
60分(fen)鐘(zhong)溫升(sheng)℃
|
阻抗電壓%
|
空載(zai)電(dian)流(liu)
%
|
質量(liang)
kg
|
電壓
V
|
電流
A
|
交(jiao)流輸(shu)出
|
直流(liu)輸出(chu)
|
電(dian)壓kV
|
電流
|
電(dian)壓kV
|
電(dian)流
|
1.5/50
|
1.5
|
200
|
7.5
|
50
|
30
|
70
|
21.4
|
500
|
50
|
10
|
<4
|
19.5
|
3/50
|
3
|
200
|
15
|
50
|
60
|
70
|
42.9
|
500
|
50
|
10
|
<4
|
27
|
5/50
|
5
|
200
|
25
|
50
|
100
|
70
|
71.4
|
500
|
50
|
10
|
<4
|
52
|
10/50
|
10
|
200
|
50
|
50
|
200
|
70
|
142.9
|
500
|
50
|
10
|
<4
|
80
|
15/50
|
15
|
400
|
37.5
|
50
|
300
|
70
|
214.3
|
500
|
50
|
8
|
<4
|
120
|
20/50
|
20
|
400
|
50
|
50
|
400
|
70
|
285.7
|
500
|
50
|
8
|
<4
|
140
|
30/50
|
30
|
400
|
75
|
50
|
600
|
70
|
428.6
|
500
|
50
|
8
|
<4
|
155
|
50/50
|
50
|
400
|
125
|
50
|
1000
|
70
|
714.3
|
500
|
50
|
8
|
<4
|
184
|
10/100
|
10
|
200
|
50
|
100
|
100
|
140
|
71.4
|
1000
|
50
|
10
|
<4
|
135
|
15/100
|
15
|
400
|
37.5
|
100
|
150
|
140
|
107.1
|
1000
|
50
|
8
|
<4
|
150
|
20/100
|
20
|
400
|
50
|
100
|
200
|
140
|
142.9
|
1000
|
50
|
8
|
<4
|
215
|
30/100
|
30
|
400
|
75
|
100
|
300
|
140
|
214.3
|
1000
|
50
|
8
|
<4
|
250
|
50/100
|
50
|
400
|
125
|
100
|
500
|
140
|
357.1
|
1000
|
50
|
8
|
<4
|
290
|
10/150
|
10
|
200
|
50
|
100
|
66.7
|
140
|
47.6
|
1500
|
50
|
10
|
<4
|
180
|
15/150
|
15
|
400
|
37.5
|
150
|
100
|
210
|
71.4
|
1500
|
50
|
8
|
<4
|
200
|
20/150
|
30
|
400
|
50
|
150
|
133.3
|
210
|
95.2
|
1500
|
50
|
8
|
<4
|
220
|
30/150
|
30
|
400
|
75
|
150
|
200
|
210
|
142.9
|
1500
|
50
|
8
|
<4
|
280
|
50/150
|
50
|
400
|
125
|
150
|
333.3
|
210
|
238.1
|
1500
|
50
|
8
|
<4
|
340
|
說明:如有特(te)殊參數(shu)要求,可按用(yong)戶的(de)技(ji)術參數(shu)進行設計(ji)制作。
上(shang)表的重(zhong)量以油(you)浸(jin)式試(shi)驗變(bian)壓器(qi)(qi)為例,干(gan)式試(shi)驗變(bian)壓器(qi)(qi)和充(chong)氣式試(shi)驗變(bian)壓器(qi)(qi)稍有不(bu)同。
五、接線及工作原理
1、調壓部分接線(xian)及原理
調(diao)壓部(bu)分由(you)控(kong)制(zhi)部(bu)分和(he)試驗變壓器(qi)(qi)組(zu)成。控(kong)制(zhi)部(bu)分是由(you)接觸(chu)式(shi)調(diao)壓器(qi)(qi)、單片機控(kong)制(zhi)系統(tong)、液(ye)晶、打(da)印機、信號測(ce)量、電(dian)路保護組(zu)成。試驗變壓器(qi)(qi)由(you)低壓繞組(zu)、高(gao)壓繞組(zu)、儀表(biao)繞組(zu)三部(bu)分組(zu)成。
試驗變(bian)壓器為交直流兩用時(shi),試驗變(bian)壓器配置(zhi)了高壓硅(gui)(gui)(gui)堆(dui)(油變(bian)、氣變(bian)為內置(zhi),干(gan)變(bian)為外(wai)置(zhi)),高壓可輸出(chu)交流和直流。輸出(chu)交流時(shi),要求接入短(duan)路(lu)桿(油變(bian)、氣變(bian))或去掉外(wai)置(zhi)硅(gui)(gui)(gui)堆(dui)(干(gan)變(bian));輸出(chu)直流時(shi),要求擰(ning)出(chu)短(duan)路(lu)桿(油變(bian)、氣變(bian))或加上外(wai)置(zhi)硅(gui)(gui)(gui)堆(dui)(干(gan)變(bian))
通(tong)過(guo)接入(ru)工(gong)(gong)頻電(dian)源,調節調壓器,以獲得所需要(yao)的試驗高壓電(dian)壓值。其工(gong)(gong)作原(yuan)理見圖1:
2、試驗(yan)部分(fen)接線及原理
做耐壓試驗時,控制部分、變壓器的接地端及(ji)高壓尾(wei)必(bi)須(xu)可(ke)靠接地。有條件的情況(kuang)下,做工頻耐壓試驗請加(jia)上限流(liu)電阻、標準高壓分壓器、球隙保(bao)護電阻及(ji)保(bao)護球隙,如圖3。
做(zuo)直(zhi)流(liu)耐壓(ya)試驗請(qing)另外加(jia)上(shang)微安表(biao),微安表(biao)必須接在硅(gui)(gui)堆和被試器之間(jian),油變或氣變一般擰(ning)在高(gao)壓(ya)頭上(shang)面(要求(qiu)擰(ning)出短(duan)路桿),干(gan)變擰(ning)在外置硅(gui)(gui)堆上(shang)面;為(wei)了更準確顯示(shi)高(gao)壓(ya)直(zhi)流(liu)泄漏電(dian)流(liu),請(qing)將分壓(ya)器的高(gao)壓(ya)線接在微安表(biao)和硅(gui)(gui)堆之間(jian),(油變、氣變)如圖(tu)4,(干(gan)變)如圖(tu)5。
耐壓(ya)試驗中(zhong)限流(liu)電(dian)(dian)阻(zu)(zu)R1應(ying)根據試驗變壓(ya)器的額(e)(e)定容量來選擇。如高壓(ya)側額(e)(e)定輸出(chu)(chu)電(dian)(dian)流(liu)在100~300mA時(shi),可取0.5~1Ω/V(試驗電(dian)(dian)壓(ya));高壓(ya)側額(e)(e)定輸出(chu)(chu)電(dian)(dian)流(liu)為1A以(yi)上時(shi),可取1Ω/V(試驗電(dian)(dian)壓(ya))。常用(yong)水(shui)電(dian)(dian)阻(zu)(zu)作為限流(liu)電(dian)(dian)阻(zu)(zu),管子長度可按150kV/m考慮,管子粗(cu)細應(ying)具有足夠的熱容量(水(shui)阻(zu)(zu)液配制方(fang)法(fa):用(yong)蒸(zheng)餾水(shui)加入適量硫(liu)酸銅配制成各種不同的阻(zu)(zu)值)。
球間(jian)(jian)隙(xi)及保護(hu)電阻:當(dang)電壓超過球間(jian)(jian)隙(xi)整定(ding)值(zhi)時(一般取(qu)試驗電壓的110%~120%),球間(jian)(jian)隙(xi)放(fang)電,對被試品起到保護(hu)作用。球間(jian)(jian)隙(xi)保護(hu)電阻可按1Ω/V(試驗電壓)選取(qu)。
在(zai)工頻(pin)耐壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)試(shi)(shi)(shi)(shi)驗(yan)中,低(di)電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)側測(ce)量電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(儀(yi)表電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya))不是(shi)非常準確的(de),其原(yuan)因(yin)是(shi)由于(yu)(yu)試(shi)(shi)(shi)(shi)驗(yan)變壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)存(cun)在(zai)著(zhu)漏抗(kang),在(zai)這(zhe)個漏抗(kang)上必然(ran)存(cun)在(zai)著(zhu)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)降或容升,使試(shi)(shi)(shi)(shi)品上的(de)電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)低(di)于(yu)(yu)或高(gao)于(yu)(yu)低(di)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)側測(ce)量電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)表上反映出來的(de)電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)。工頻(pin)耐壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)試(shi)(shi)(shi)(shi)驗(yan)時(shi)(shi),被(bei)試(shi)(shi)(shi)(shi)品上的(de)電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)高(gao)于(yu)(yu)試(shi)(shi)(shi)(shi)驗(yan)變壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)的(de)輸出電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya),也(ye)就是(shi)所謂容升現象。感(gan)應耐壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)試(shi)(shi)(shi)(shi)驗(yan)時(shi)(shi),試(shi)(shi)(shi)(shi)驗(yan)變壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)的(de)漏抗(kang)必然(ran)存(cun)在(zai)著(zhu)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)降。為了準確測(ce)量被(bei)試(shi)(shi)(shi)(shi)品上所施加的(de)電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya),因(yin)此常在(zai)高(gao)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)側接入標準高(gao)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)分壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)來測(ce)量電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)。
六(liu)、操作要點
1、試(shi)驗前,應了(le)(le)解(jie)被試(shi)品(pin)的(de)試(shi)驗電壓(ya),同時了(le)(le)解(jie)被試(shi)品(pin)的(de)其他試(shi)驗項目(mu)及以前的(de)試(shi)驗結果。若(ruo)被試(shi)品(pin)有缺陷或異常(chang),應在消除后(hou)再(zai)進行耐壓(ya)試(shi)驗。
2、試(shi)驗現場應圍好遮(zhe)攔或(huo)圍繩(sheng),掛好標示牌,并派專人監護(hu)。
3、試驗(yan)前,被試品表面(mian)應擦拭干(gan)凈,將被試品的(de)外殼和(he)非被試繞(rao)組可靠接地。被試品為新沖油設(she)備(bei)(bei)時(shi),應按《規(gui)程》規(gui)定(ding)使油靜止一定(ding)時(shi)間再升壓(ya),對110kV及以(yi)下(xia)的(de)充(chong)油電力(li)設(she)備(bei)(bei),在(zai)注滿油后靜置時(shi)間應不(bu)少于24小時(shi),對220kV及330kV的(de)充(chong)油電力(li)設(she)備(bei)(bei),靜置時(shi)間應不(bu)少于48小時(shi)。
4、接(jie)好(hao)試驗(yan)接(jie)線后,應由有經驗(yan)的(de)人(ren)員檢查(cha),確認無(wu)誤后方可升壓(ya)。
5、升(sheng)壓(ya)前,首先檢(jian)查調壓(ya)器是否在零位(wei)。調壓(ya)器在零位(wei)方可升(sheng)壓(ya)。
6、升壓(ya)過程中不(bu)僅(jin)要監視(shi)電(dian)(dian)壓(ya)的變(bian)化(hua),還應監視(shi)電(dian)(dian)流(liu)的變(bian)化(hua),以及被試品(pin)泄漏(lou)電(dian)(dian)流(liu)的變(bian)化(hua)。升壓(ya)時要均勻升壓(ya),不(bu)能(neng)太(tai)快。升至規(gui)定(ding)試驗(yan)電(dian)(dian)壓(ya)時,開(kai)始(shi)計(ji)時,時間到后,緩慢均勻降下(xia)電(dian)(dian)壓(ya)。絕不(bu)允許不(bu)降壓(ya)就先跳(tiao)開(kai)電(dian)(dian)源開(kai)關。
7、試(shi)(shi)驗中(zhong)發(fa)現被試(shi)(shi)品有異常聲響(xiang)、冒煙等應(ying)立即降(jiang)下電(dian)壓,拉開電(dian)源,在高壓側掛(gua)上(shang)接地線(xian)后(hou),再(zai)查(cha)明原因。耐壓試(shi)(shi)驗前后(hou)均(jun)應(ying)測(ce)量被試(shi)(shi)品的絕緣(yuan)電(dian)阻。
七、面板功能(neng)說明(ming)
打(da)(da)(da)印(yin)(yin)機(ji):打(da)(da)(da)印(yin)(yin)機(ji)是熱敏(min)打(da)(da)(da)印(yin)(yin)機(ji),當試驗(yan)完成后按鍵盤上的“打(da)(da)(da)印(yin)(yin)”按鈕打(da)(da)(da)印(yin)(yin)試驗(yan)結果。
RS232:RS232是與計算(suan)機(ji)相連的串(chuan)口通信接(jie)口,是用戶(hu)選配(pei)接(jie)口,本(ben)裝(zhuang)置沒有配(pei)置這個(ge)接(jie)口。
LCD對(dui)比(bi)度(du):因為液(ye)晶顯(xian)示屏在溫度(du)和光(guang)線有所(suo)不(bu)同(tong)時稍有些變化,可以通過LCD對(dui)比(bi)度(du)調節背光(guang)到(dao)適(shi)合亮度(du)。
液晶: 320x240像素點陣白色背光液晶,在(zai)強光和陰暗環境下都十分清楚(chu)。
指示(shi)(shi)(shi)燈:由(you)啟(qi)動燈、零(ling)位燈、指示(shi)(shi)(shi)燈三個燈組成,啟(qi)動燈和警示(shi)(shi)(shi)燈是高(gao)亮七(qi)彩燈。
操作提示(shi):有一些簡短(duan)的提示(shi)語句和安(an)裝接線圖。
緊急(ji)開關(guan):在(zai)(zai)緊急(ji)情(qing)況(kuang)下按此開關(guan),即(ji)可以(yi)切斷(duan)變壓器電源,也可以(yi)切斷(duan)工作(zuo)電源。(箱式安裝在(zai)(zai)面(mian)板上(shang),臺式安裝在(zai)(zai)柜體(ti)上(shang))
鍵盤:由(you)上、下(xia)、左、右(you)、設置(zhi)、打印、確定、取消8個鍵組成,是用戶和設備交互的(de)終端。
電源開關:工作電源,帶通電指示燈。
八、軟(ruan)件使用說(shuo)明
按試(shi)驗要求將(jiang)控制(zhi)部(bu)分、試(shi)驗變壓器、被試(shi)品正確(que)接好線(xian),必須可靠接地,請參(can)考圖(tu)(tu)1、圖(tu)(tu)2、圖(tu)(tu)3、圖(tu)(tu)4、圖(tu)(tu)5。
1、開機使用
開機處于(yu)“歡迎(ying)界(jie)面(mian)”,如(ru)圖7:
根據鍵(jian)盤的(de)示圖8,按上↑、下↓、左←,右→可以切換“自動(dong)(dong)耐壓試驗(yan)”或(huo)“手動(dong)(dong)耐壓試驗(yan)”,在“自動(dong)(dong)試驗(yan)”或(huo)“手動(dong)(dong)試驗(yan)”里面(mian)選擇(ze)“交流試驗(yan)方式(shi)”或(huo)“直流試驗(yan)方式(shi)”。如圖9
說(shuo)明:
(1)當配置的(de)是(shi)交直流(liu)兩用(yong)控制部分時(shi)(shi),使用(yong)直流(liu)輸出時(shi)(shi)軟件操作(zuo)請(qing)進(jin)入直流(liu)試驗方(fang)式,交流(liu)輸出時(shi)(shi)軟件操作(zuo)請(qing)進(jin)入交流(liu)試驗方(fang)式,如果選擇錯(cuo)誤會(hui)導致(zhi)(zhi)儀器顯示電壓(ya)會(hui)和輸出實際電壓(ya)不一致(zhi)(zhi)。
(2)當(dang)配置的是交直流兩用(yong)變(bian)壓(ya)器(qi)時,使用(yong)直流時請(qing)將(jiang)變(bian)壓(ya)器(qi)的短路(lu)桿(gan)取(qu)出,當(dang)使用(yong)交流時請(qing)將(jiang)短路(lu)桿(gan)插入擰緊。
(3)如果配置的是交流控制部分(fen)時(shi),軟(ruan)件界(jie)面里就沒(mei)有(you)交直流試驗方式(shi)(如圖9)的選擇項。
選(xuan)中試驗方式后(hou),按確定可以進入(ru)主(zhu)界面,如圖(tu)10:
動態顯示(shi)區:一直處于采集(ji)信(xin)號(hao),并顯示(shi)高(gao)壓(ya)(ya)電(dian)壓(ya)(ya)、高(gao)壓(ya)(ya)電(dian)流(liu)、低壓(ya)(ya)電(dian)壓(ya)(ya)、低壓(ya)(ya)電(dian)流(liu)。
結果(guo)顯(xian)示(shi)區:如果(guo)試驗沒有被擊穿時,顯(xian)示(shi)平(ping)(ping)均(jun)(jun)高壓(ya)電(dian)(dian)壓(ya),平(ping)(ping)均(jun)(jun)高壓(ya)電(dian)(dian)流(liu),平(ping)(ping)均(jun)(jun)低壓(ya)電(dian)(dian)壓(ya),平(ping)(ping)均(jun)(jun)低壓(ya)電(dian)(dian)流(liu),絕緣電(dian)(dian)阻;否(fou)之,顯(xian)示(shi)峰(feng)值電(dian)(dian)壓(ya),峰(feng)值電(dian)(dian)流(liu),低壓(ya)電(dian)(dian)壓(ya),低壓(ya)電(dian)(dian)流(liu)。
設置數(shu)據區:設置試(shi)驗(yan)中需要的(de)參數(shu)數(shu)據輸出電(dian)(dian)(dian)壓(ya)(ya)(ya)為(wei)(wei)在自動方式(shi)下的(de)升壓(ya)(ya)(ya)目標(biao)耐壓(ya)(ya)(ya)值(zhi)耐壓(ya)(ya)(ya)時(shi)間為(wei)(wei)耐壓(ya)(ya)(ya)過(guo)(guo)程(cheng)的(de)時(shi)間長度(du)電(dian)(dian)(dian)流(liu)上限(xian)(xian)為(wei)(wei)高壓(ya)(ya)(ya)電(dian)(dian)(dian)流(liu)峰值(zhi)的(de)上限(xian)(xian),高壓(ya)(ya)(ya)電(dian)(dian)(dian)流(liu)超(chao)過(guo)(guo)電(dian)(dian)(dian)流(liu)上限(xian)(xian)將認為(wei)(wei)擊穿過(guo)(guo)流(liu)保護(hu)(hu)為(wei)(wei)低壓(ya)(ya)(ya)電(dian)(dian)(dian)流(liu)峰值(zhi)的(de)上限(xian)(xian),低壓(ya)(ya)(ya)電(dian)(dian)(dian)流(liu)超(chao)過(guo)(guo)過(guo)(guo)流(liu)保護(hu)(hu)將認為(wei)(wei)擊穿
信息(xi)顯示區:顯示試驗(yan)過程中(zhong)的試驗(yan)狀(zhuang)態和提示信息(xi)。
試(shi)驗操作區:選擇設置、試(shi)驗、回(hui)零命令(ling)。
2、設置參數
在主界面上,選中“設(she)置(zhi)(zhi)”,然(ran)后(hou)按(an)確定后(hou)進入設(she)置(zhi)(zhi)界面,如圖11:
按左←,右→時切換光(guang)標(biao)移動(dong)位置(zhi)(zhi),按上↑、下↓時更(geng)改光(guang)標(biao)位置(zhi)(zhi)數據的(de)值。光(guang)標(biao)位置(zhi)(zhi)和設置(zhi)(zhi)的(de)數值全部可(ke)以自動(dong)循環,前且在(zai)使用時有默(mo)認的(de)標(biao)準(zhun)值。如果所(suo)有的(de)參(can)數都設置(zhi)(zhi)完(wan)成,按取消退出(chu)設置(zhi)(zhi)回到(dao)主(zhu)界(jie)面(mian)開始狀態。
3、手動試驗
零(ling)位檢查—當選中“試(shi)驗”后(hou),按確(que)定(ding)就進(jin)入提示試(shi)驗狀態。如果(guo)調壓器不在零(ling)位,將提示“試(shi)驗前請先(xian)回零(ling)”,退出試(shi)驗并且切換(huan)到回零(ling)命(ming)令(ling)。
試驗過(guo)程—回零確(que)認后,可以(yi)進行試驗。選(xuan)中“試驗”后按確(que)定,接(jie)觸器合閘,這時(shi)輸出電壓幾乎為0,如圖12:
按上↑,高壓電壓將不斷升壓,松開(kai)就停(ting)止(zhi)升壓,如果(guo)到上限就提(ti)示滿量程(cheng);
按下↓,高壓(ya)電(dian)壓(ya)將不斷降(jiang)壓(ya),松開(kai)就停止降(jiang)壓(ya),如(ru)果到下限就提示已回零;
按計時(shi)(shi)←,計時(shi)(shi)開(kai)始工作(zuo),到耐壓時(shi)(shi)間計時(shi)(shi)結束完成試驗(yan);
按取消(xiao)→,取消(xiao)試驗過程;
在升壓(ya)(ya)(ya)(ya)過程中,如果(guo)高(gao)(gao)壓(ya)(ya)(ya)(ya)電(dian)流(liu)(liu)(liu)峰(feng)(feng)值超(chao)過“電(dian)流(liu)(liu)(liu)上限”值或低(di)壓(ya)(ya)(ya)(ya)電(dian)流(liu)(liu)(liu)峰(feng)(feng)值超(chao)過“過流(liu)(liu)(liu)保護(hu)”值將(jiang)認為被(bei)試品(pin)被(bei)擊穿(chuan),接觸器(qi)立刻分閘并顯示(shi)(shi)試驗(yan)結(jie)果(guo),包括峰(feng)(feng)值電(dian)壓(ya)(ya)(ya)(ya)、峰(feng)(feng)值電(dian)流(liu)(liu)(liu)、低(di)壓(ya)(ya)(ya)(ya)電(dian)流(liu)(liu)(liu)等(deng),調(diao)壓(ya)(ya)(ya)(ya)器(qi)開始回零,回零完(wan)成試驗(yan)結(jie)束。如果(guo)在耐(nai)(nai)壓(ya)(ya)(ya)(ya)過程中,高(gao)(gao)壓(ya)(ya)(ya)(ya)電(dian)流(liu)(liu)(liu)和低(di)壓(ya)(ya)(ya)(ya)電(dian)流(liu)(liu)(liu)峰(feng)(feng)值沒有(you)超(chao)設置上限值,認為被(bei)試品(pin)未擊穿(chuan),結(jie)果(guo)顯示(shi)(shi)區就顯示(shi)(shi)耐(nai)(nai)壓(ya)(ya)(ya)(ya)電(dian)壓(ya)(ya)(ya)(ya)、高(gao)(gao)壓(ya)(ya)(ya)(ya)電(dian)流(liu)(liu)(liu)、低(di)壓(ya)(ya)(ya)(ya)電(dian)流(liu)(liu)(liu)、絕緣電(dian)阻等(deng),調(diao)壓(ya)(ya)(ya)(ya)器(qi)開始回零,回零完(wan)成后接觸器(qi)分閘試驗(yan)結(jie)束。
4、自動試驗(yan)
自動(dong)試驗(yan)和手(shou)動(dong)試驗(yan)的試驗(yan)過程類(lei)似,首先也進行回(hui)零(ling)檢查(cha),確(que)認后進入如下界面(mian),如圖13:
按(an)上(shang)方法(fa)切換到(dao)“開(kai)始(shi)”確定后(hou)進行試驗(yan),與手動(dong)試驗(yan)不(bu)同之處(chu)就是(shi)升壓過程將自動(dong)升壓到(dao)“輸出電壓”值,然后(hou)進行計時。
升(sheng)壓(ya)過(guo)程(cheng)為(wei)逼近方(fang)式,首先升(sheng)到(dao)到(dao)接近目標值(zhi),然后再(zai)進行微調,保證(zheng)高(gao)壓(ya)電壓(ya)值(zhi)幾乎為(wei)輸出電壓(ya)值(zhi)。
5、功能(neng)選(xuan)擇
按鍵(jian)盤上的“設置”就進(jin)入功能界面,如(ru)圖(tu)14:
進入功(gong)能界(jie)面后(hou),可(ke)以選(xuan)擇(ze)“時鐘(zhong)設置”、“注意事項”等界(jie)面。
時鐘(zhong)設置:設置時鐘(zhong)的時間(jian),為打(da)印報表提供(gong)時間(jian)依據。
注意事項:為用戶(hu)提供一(yi)些操(cao)作(zuo)規范和(he)**注意事項。
6、打印
按(an)鍵盤(pan)“打(da)印”按(an)鍵可(ke)以打(da)印試(shi)驗(yan)果,在此不(bu)贅述。
七、產品維(wei)護
1、開箱驗收時,應檢查主控回路接線是否(fou)松動,調壓(ya)器電刷是否(fou)接觸(chu)良好。
2.、長期(qi)不(bu)用(yong)時(shi),使用(yong)前應用(yong)500V兆歐表測量絕緣(yuan)電(dian)阻,其阻值不(bu)低于0.5MΩ。
3、電源電壓應符合控制箱(臺)說明書上的輸(shu)入電壓值要求。
4、本控制箱(臺(tai))設(she)有過電(dian)流保護,出(chu)廠已(yi)調(diao)整為額(e)(e)定(ding)電(dian)流的(de)50%。用于小(xiao)負載時(shi),應根據被試品的(de)額(e)(e)定(ding)容量電(dian)流重新(xin)設(she)定(ding);
5、使用完畢后,應關好控制箱(臺)門蓋,以保(bao)持內部清潔(jie)。
八、注意事項
1、按照您所進行的(de)(de)試(shi)驗(yan)接好工作線路。試(shi)驗(yan)變(bian)壓器(qi)的(de)(de)外(wai)殼(ke)以及操(cao)作系統(tong)的(de)(de)外(wai)殼(ke)必(bi)(bi)須可(ke)靠接地(di)(di)。試(shi)驗(yan)變(bian)壓器(qi)的(de)(de)測量繞組的(de)(de)F端和(he)外(wai)殼(ke)必(bi)(bi)須可(ke)靠接地(di)(di)。
2、做(zuo)串(chuan)級(ji)試驗時,**級(ji)、第三(san)級(ji)試驗變(bian)壓(ya)器的(de)低壓(ya)繞(rao)組(zu)成X端(duan),測量繞(rao)組(zu)的(de)F端(duan)以及高壓(ya)繞(rao)組(zu)的(de)X端(duan)(高壓(ya)端(duan))均接(jie)本級(ji)試驗變(bian)壓(ya)器具(ju)外(wai)殼。**級(ji)、第三(san)級(ji)試驗變(bian)壓(ya)器的(de)外(wai)殼必(bi)須通(tong)過絕緣(yuan)支(zhi)架接(jie)地。
接通(tong)電源(yuan)前,控(kong)制(zhi)箱(臺)的調壓器必須調到零位后(hou)方(fang)可接通(tong)電源(yuan),合閘,開始升壓。
3、從零(ling)開(kai)始勻速(su)(su)(su)旋轉調壓(ya)器(qi)手(shou)輪升(sheng)(sheng)壓(ya)。升(sheng)(sheng)壓(ya)方式有(you):快速(su)(su)(su)升(sheng)(sheng)壓(ya)法(fa),即(ji)20s逐級升(sheng)(sheng)壓(ya)法(fa);慢速(su)(su)(su)升(sheng)(sheng)壓(ya)法(fa),即(ji)60s逐級升(sheng)(sheng)壓(ya)法(fa);極慢速(su)(su)(su)升(sheng)(sheng)壓(ya)法(fa)供選(xuan)用。電(dian)壓(ya)從零(ling)開(kai)始按(an)一定(ding)(ding)的升(sheng)(sheng)壓(ya)方式和速(su)(su)(su)度(du)上(shang)升(sheng)(sheng)到您所需(xu)的額(e)(e)定(ding)(ding)試(shi)驗(yan)電(dian)壓(ya)的75%后(hou),再以每秒2%額(e)(e)定(ding)(ding)試(shi)驗(yan)電(dian)壓(ya)的速(su)(su)(su)度(du)升(sheng)(sheng)到您所需(xu)的試(shi)驗(yan)電(dian)壓(ya),并密(mi)切注意(yi)測量儀表的及被試(shi)品的情(qing)況。升(sheng)(sheng)壓(ya)過程中或試(shi)驗(yan)過程中如發現測量儀表的指示及被試(shi)品情(qing)況異常(chang),應立即(ji)降壓(ya),切斷電(dian)源,查明(ming)情(qing)況。
4、試驗完畢后,應在等(deng)調壓器返回至零位,然后切斷(duan)電源。
5、本產品(pin)不得超過(guo)額(e)定參數使用。
6、使(shi)用(yong)本(ben)產(chan)品做高壓(ya)試(shi)驗(yan)時,除熟(shu)悉本(ben)說(shuo)明書外,還必須(xu)嚴格執行國家有關(guan)標準和(he)操作規程(cheng)(cheng)。可參照(zhao)GB311.1 – 97《高壓(ya)輸變(bian)設備的絕緣(yuan)配合,高壓(ya)試(shi)驗(yan)技術》;《電(dian)氣設備預防性試(shi)驗(yan)規程(cheng)(cheng)》等(deng)。
7、控(kong)制(zhi)箱(xiang)(臺(tai))應與試驗變壓(ya)器配套使用,控(kong)制(zhi)箱(xiang)(臺(tai))的(de)使用方(fang)法,請詳(xiang)細參閱控(kong)制(zhi)器的(de)使用說明(ming)書。