近期,隨著華中地區大范圍持續(xu)高溫天(tian)氣(qi)的(de)結束和水(shui)(shui)電(dian)(dian)來水(shui)(shui)的(de)增(zeng)加,今年夏季以來華中電(dian)(dian)網(wang)長時間持續(xu)的(de)電(dian)(dian)力(li)電(dian)(dian)量供需(xu)矛盾得到緩解。國家電(dian)(dian)網(wang)有限公(gong)司華中分部緊(jin)盯電(dian)(dian)網(wang)運行形勢變化,及時調(diao)整電(dian)(dian)網(wang)運行策略,調(diao)度運行工作重點從之前的(de)“內增外引”,即區域內(nei)挖(wa)潛增(zeng)供(gong)電(dian)(dian)(dian)量、跨區全(quan)力爭取電(dian)(dian)(dian)量支援、保障(zhang)電(dian)(dian)(dian)力電(dian)(dian)(dian)量供(gong)應,轉變(bian)為“內減(jian)外引”,即通過減少(shao)區域內火力發電(dian)(dian)全力消納(na)跨區外來(lai)電(dian)(dian)量,保(bao)障水電(dian)(dian)、新能源(yuan)消納(na),同時(shi)督(du)促火電(dian)(dian)廠利用有(you)利時(shi)機做好電(dian)(dian)煤儲備。
截(jie)至(zhi)8月12日,華中電(dian)網(wang)*大用(yong)電(dian)負荷從月初的(de)1.57億千瓦(wa)高位回落至(zhi)1.3億千瓦以下,水電(dian)發電(dian)出力(li)從3319萬千瓦(wa)增加至3993萬千瓦。與(yu)此同(tong)時,渝(yu)鄂直流通(tong)道日交換電量(liang)由(you)華中送(song)西南2595萬千瓦時(shi),反轉(zhuan)為西南送華中2493萬千瓦(wa)時。
第1章
系統概述(shu)(WBXT2000SF6氣體泄漏定量監測系統操(cao)作簡單,方(fang)便(bian)適用)
SF6氣(qi)體(ti)背景簡介
六氟化硫(liu)(SF6)氣(qi)體(ti)由法國兩位化學家Moissan和Lebeau于1900年合成(cheng),它(ta)以(yi)其優(you)異(yi)的(de)絕緣和滅弧性(xing)(xing)能,在(zai)(zai)電力系統中得到(dao)廣泛應(ying)用。雖然在(zai)(zai)常態(tai)下(xia),SF6氣(qi)體(ti)是一種無(wu)色、無(wu)味、無(wu)毒(du)(du)的(de)惰性(xing)(xing)氣(qi)體(ti),但在(zai)(zai)高壓電弧的(de)作用下(xia),這種氣(qi)體(ti)會發生分解(jie),遇(yu)到(dao)水份后還會產生一些劇(ju)毒(du)(du)物質,如氟(fu)化(hua)亞硫(liu)酰(SOF2)、四氟(fu)化(hua)硫(liu)(SF4)、二氟(fu)化(hua)硫(liu)(SF2)等,類似這些劇(ju)毒(du)(du)物質即便是微量也能致人非(fei)命。
當前(qian),SF6氣體在中(zhong)、高壓設備(bei)中(zhong)的大量使用,其(qi)保障(zhang)性(xing)已受(shou)到人們的普遍關注。針對SF6比空(kong)氣重,泄漏(lou)易(yi)聚集,易(yi)造成低層空(kong)間缺氧,空(kong)氣含毒(du)環境對(dui)人(ren)員(yuan)的威(wei)脅(xie)等(deng)問題,有關部門已(yi)制訂(ding)了(le)一系列相應的行業法規(gui)(gui),法規(gui)(gui)中明(ming)確規(gui)(gui)定了(le)人(ren)員(yuan)在進入SF6配(pei)電裝置(zhi)室時必須先通風15分鐘,對空(kong)氣中的SF6氣(qi)體濃度及氧氣(qi)含量進行監(jian)測,在SF6配(pei)電裝置的低位區應安裝能報警的氧量儀和(he)SF6氣體報(bao)警儀。
WBXT2000型SF6氣(qi)體泄漏報警監控系統,正(zheng)是按照(zhao)這些(xie)行(xing)業(ye)法規而開發設計的一種智能化在(zai)線監測系統。
系統特點與主要功能(WBXT2000SF6氣體泄漏定量監測系統操作簡單,方便(bian)適(shi)用)
先進的傳感器技術
采(cai)用超聲波測速技術,可定量檢(jian)測SF6氣(qi)體濃度。
多重檢測(ce)功(gong)能
主要(yao)針對SF6氣體泄漏(lou)和缺(que)氧狀況進行檢(jian)測,并(bing)兼有溫度、濕度等環境數據的輔(fu)助(zhu)檢(jian)測功能,完全符合(he)《電業保(bao)障(zhang)工(gong)作規程(cheng)》要(yao)求。
早期(qi)現場(chang)報(bao)警技術(shu)
微量檢測技術能發出早期現場警報,并指示氣體泄漏位(wei)置,及(ji)時通(tong)知(zhi)危險地點內人員疏散,尋找及(ji)消(xiao)除泄漏源(yuan),保護運行(xing)設備。
現場總線設(she)計
一根電(dian)纜連接所有采集器及主機,可分立(li)可組合,具有很高的現場適應性。
多點(dian)組網檢測(ce)
*多128點同時檢(jian)測(可根據用戶需求(qiu)擴展),滿足現(xian)場環(huan)境需要,提高檢(jian)測可靠性。
遠程控制能(neng)力
數(shu)據(ju)可傳送到遠(yuan)方(fang)控(kong)(kong)制(zhi)(zhi)(zhi)中心,控(kong)(kong)制(zhi)(zhi)(zhi)中心也可直接遠(yuan)程查詢、控(kong)(kong)制(zhi)(zhi)(zhi)監控(kong)(kong)系統(tong)。
開放(fang)性設計
可(ke)方(fang)便(bian)組(zu)成遠程監(jian)控系(xi)(xi)統(tong),實現遙測、遙控功(gong)能;系(xi)(xi)統(tong)通訊采用標(biao)準通信(xin)規約,系(xi)(xi)統(tong)可(ke)方(fang)便(bian)接入綜自監(jian)控系(xi)(xi)統(tong)或其他系(xi)(xi)統(tong)。
長壽型(xing)設計
充(chong)分利用單片機的工作(zuo)(zuo)靈活性(xing),傳(chuan)感器(qi)采取(qu)間歇式工作(zuo)(zuo)測量,大大提高了傳(chuan)感器(qi)的工作(zuo)(zuo)穩定性(xing)和(he)使用壽(shou)命(ming)。
歷史數(shu)據記錄和(he)查詢
大容量數據存(cun)儲器,可(ke)通過(guo)筆記本(ben)電腦等外(wai)設進行(xing)快捷查詢。
自動語音提示、報警
自動(dong)語音(yin)提示實時檢測結(jie)果,加強現場工(gong)作(zuo)人員的直觀(guan)感覺(jue)。
免(mian)維護(hu)設(she)計
整機無可調節器件,高等級(ji)、品質保證(zheng)的元器件選用,優(you)異的抗干擾(rao)性能。
系統主要技術特性(xing)(WBXT2000SF6氣體泄漏定量監測系統操作簡單,方便適(shi)用)
工作環境··································
|
-10-50℃, 環境濕(shi)度(du)≤95%,海(hai)拔2000米以下
|
工作電源··································
|
AC/DC 185-265V
|
功耗··········································
|
主機:<20VA 變(bian)送器:<5W
|
SF6氣體泄漏報(bao)警值·················
|
缺(que)省:1000ppm,可根據需求(qiu)執行(xing)設置
報警(jing)誤差<5%(V/V)
|
氧含量檢測范圍······················
|
0-25.0%(V/V), <0.5%(V/V) 低于18.0%報警
|
風(feng)機啟動··································
··················································
··················································
|
1.SF6氣體泄漏時自動通風
2.氧(yang)氣含量(liang)≤18.0%時風機自動啟動
3.自動(dong)定(ding)時排風
4.可手動強制啟(qi)動風機排風
|
··················································
|
溫度(du)顯示范圍
|
-20-99℃
|
濕度(du)顯(xian)示(shi)范圍
|
0-99%RH
|
報警輸出觸(chu)點(dian)功率··················
|
AC220V/3A
|
風機輸出(chu)觸點功率··················
|
AC220V/3A(增加風機控制器為30A)
|
絕緣性(xing)能··································
|
>10MΩ(外(wai)殼(ke)與(yu)電源(yuan)間)
|
抗(kang)電強(qiang)度··································
|
>2000V(外殼與電源間)
|
電(dian)磁兼容(rong)特性(xing)··························
|
快速瞬變脈沖群 GB/T17626.4-1999 3級(ji)
|
··················································
|
雷(lei)擊(浪涌) GB/T17626.5-1999 3級
|
變送(song)器(qi)與(yu)主(zhu)機通訊··················
|
標(biao)準RS485接口,波特率4800BPS
|
RTU通訊···································
|
標準RS485、RS232接口,波特率4800BPS
|
第2章
基本操作指南(WBXT2000SF6氣體泄漏定量監測系統操作簡單,方(fang)便適用(yong))
開機
打開電源,主(zhu)機(ji)進入(ru)初(chu)始化(hua)。
系統操(cao)作
按(an)鍵功能
共有“上(shang)”、“下”、“左”、“右”、“靜音(yin)”、“通風(feng)”、“返回”、“確定”8個功能鍵,對應(ying)8種操作,按(an)下(xia)按(an)鍵(jian),聽到蜂(feng)鳴(ming)器“吡(bi)”聲后,松(song)開按(an)鍵(jian),繼續下(xia)一步(bu)操作。
屏幕下部各(ge)項功能菜(cai)(cai)單在(zai)反(fan)顯時處于激活狀(zhuang)態,按“確定”進入(ru)菜(cai)(cai)單功能,按“上”、“下”切換菜(cai)(cai)單。
“靜(jing)音”取消提示音一小(xiao)時(shi),一小(xiao)時(shi)后恢復(fu)
按(an)“通風”鍵(jian),風機工(gong)作工(gong)作15分鐘后自動停止,在通風時按下“通風”鍵(jian)風機停止
采集數據
采集周期設(she)置默認為1分鐘/次,可根(gen)據需要修改(1-30分(fen)鐘)。
主界(jie)面下(xia)選中“即時(shi)采集(ji)”菜(cai)單(dan)按“確定(ding)”鍵,即可實(shi)時(shi)采集(ji)數據。
報警(jing)記錄查詢
主界面下選中“報警記(ji)錄”菜單按“確定”鍵,可(ke)直接查(cha)詢報警記(ji)錄。
(按“返回”鍵返回主界面)
歷史數據查詢
主界面(mian)下(xia)選中“歷(li)史數(shu)據(ju)”菜(cai)單按(an)“確定”鍵,查詢歷(li)史數(shu)據(ju)。(按(an)“返回”鍵返回主界面(mian))
系(xi)統(tong)設置(非系(xi)統(tong)維護人員,請勿進入(ru)“系(xi)統(tong)設置”)
選(xuan)擇(ze)按(an)鍵“系統設置”,入密(mi)碼輸入窗口(kou);
輸入正確(que)密碼后按(an)“確(que)認”鍵進入,或(huo)者按(an)“取消”鍵退出;
(密碼按四下(xia)“上”鍵)
輸入(ru)正確密(mi)碼進入(ru)系統(tong)設置(zhi)窗口后,通過“上”鍵或“下”鍵選(xuan)擇修改項,按“確認”鍵,進入(ru)相應(ying)操(cao)作界(jie)面。
按(an)(an)“上(shang)”鍵或“下”鍵可對所選中(zhong)的系統(tong)時鐘(zhong)、定時排風啟(qi)停時間等進行(xing)設置(zhi),通過“左”鍵或“右”鍵選擇域,*后按(an)(an)“確(que)認”鍵保存修改,選中(zhong)“返回(hui)”放棄修改;
進(jin)行“確認”或“取消/返回”功能(neng)操作(zuo)后系統回到(dao)主菜單選擇界面。
注意(yi):非系統維護人員(yuan),請勿進入“系統設置”。
第3章系統結構(gou)示意圖(WBXT2000SF6氣體泄漏定量監測系統操作(zuo)簡單,方便適用)
系統的連接(jie)與(yu)安裝
系(xi)統(tong)主(zhu)機(ji):屏(ping)柜(ju)式或(huo)壁掛式。一(yi)般安(an)裝于(yu)(yu)主(zhu)控室內專用屏(ping)柜(ju)上或(huo)開(kai)關室門口,高度以便(bian)于(yu)(yu)觀察顯示窗且便(bian)于(yu)(yu)操作為宜,連接AC220V電源及通(tong)訊電纜、警(jing)燈(deng)及風(feng)機控制輸(shu)出(chu)。
SF6氣(qi)體(ti)采集器一般根據氣(qi)室分(fen)布情況(kuang)進行布點(dian),安(an)裝于距地(di)面(mian)0—10cm的槽鋼(gang)或地面上,使(shi)之既要保障能(neng)及時監測現場環境情況,又不浪費設備資源(yuan)。
所有數(shu)據連接(jie)線應采(cai)用(yong)屏蔽電纜。
第4章
用戶須知(zhi)與常見故障
用戶須知
氣體(ti)采集器在使(shi)用過程中應(ying)該避免大量(liang)灰塵和(he)化(hua)學品的侵入;
主機及采(cai)集器嚴(yan)禁覆蓋、擠壓、碰撞(zhuang),以及不(bu)恰當(dang)的(de)操(cao)作,避免影響系統(tong)正常工作,甚至導致損壞(huai)!
常見故障排除
請(qing)參照(zhao)以下辦法,依次進行故障(zhang)排(pai)除:
系統主(zhu)機(ji)無(wu)任何顯示
檢查(cha)是否有(you)電源(yuan)輸入;
檢查(cha)主機電源開(kai)關是否(fou)打(da)開(kai);
打開主機接線盒,檢查電源輸(shu)入(ru)插座是否緊固;
如果進行以(yi)上檢查均沒有發現問題,請(qing)立即與我們的技術(shu)支持人員聯系(xi)。
主機或(huo)顯示單元顯示混亂或(huo)部(bu)分(fen)無(wu)顯示
關閉系統總(zong)電(dian)源10秒后重新啟(qi)動
檢查采集器(qi)接線插頭是否緊固;
如果進行以上檢(jian)查均沒(mei)有發現(xian)問題(ti),請立(li)即(ji)與我們的技術支持(chi)人員(yuan)聯系(xi)。
其它問題請直接(jie)與我們聯(lian)系!
近(jin)日,華中(zhong)全網累(lei)計安排調停火電機(ji)組46臺,容量(liang)2269萬千瓦,湖北、江西火電已(yi)經接(jie)近或達(da)到保障電網(wang)可靠及跨區直流(liu)送(song)(song)(song)電、調試的(de)*小方式(shi)。目前,天(tian)中、祁韶、青豫、雅湖四大特(te)高壓直流(liu)均按照送(song)(song)(song)受(shou)端(duan)能力很大限度安(an)排送(song)(song)(song)電,湖南受(shou)電通(tong)道(dao)(dao)全天(tian)送(song)(song)(song)滿(man),鄂豫通(tong)道(dao)(dao)送(song)(song)(song)河南全天(tian)送(song)(song)(song)滿(man),重(zhong)慶低(di)谷外(wai)送(song)(song)(song)水(shui)電全額安(an)排消納。
8月(yue)12日,華中電(dian)網網內(nei)清潔能源發電(dian)與(yu)跨區凈受電(dian)之和占用電(dian)負(fu)荷比重*大超(chao)過50%,較8月初提(ti)高10個百分(fen)點以(yi)上。隨著電煤耗用減(jian)少(shao),華中全(quan)網電煤庫存已經開(kai)始企穩回升。
目前(qian),國網華中分部持續關注天氣(qi)和來水變化,加強電網統一調度,按照“高峰保平衡(heng)、低谷促消納、全天送(song)電量(liang)”的原則,一方面(mian)保障華中電(dian)網用(yong)電(dian)高峰電(dian)力(li)供應,一方面(mian)提(ti)升水電(dian)、新(xin)能(neng)源消納能(neng)力(li),同時*大限(xian)度(du)增供河南、湖南電(dian)量(liang),幫助減少電(dian)煤耗用(yong),增加庫存。
揚(yang)州萬寶轉載(zai)其他(ta)網站內容,出于傳遞更多信息而(er)非盈利之目的,同(tong)時(shi)并不代表(biao)贊成其觀點或(huo)證實(shi)其描(miao)述,內容僅供參考。版權歸原作者所有,若有侵(qin)權,請(qing)聯系我們刪除。