WBPCD-4000 TEV在線局放儀概述
系統(tong)介紹
WBPCD-4000局部放電檢(jian)測儀可(ke)配合使用特高頻傳感器、TEV傳感(gan)(gan)(gan)器、聲(sheng)電組合傳感(gan)(gan)(gan)器、超(chao)聲(sheng)傳感(gan)(gan)(gan)器和寬頻帶電流互感(gan)(gan)(gan)器(HFCT)在線檢測變壓器、高壓開關(guan)柜、GIS、電纜接(jie)頭等高壓設備的(de)局部放電情況。攜帶(dai)方便(bian)、測量快速,抗(kang)干擾能力強,便(bian)于(yu)現場使(shi)用。
其配置軟(ruan)(ruan)件(jian)具有(you)實時波(bo)形(xing)圖、*大峰值(zhi)顯示、定位等功能,軟(ruan)(ruan)件(jian)也可(ke)以詳查分(fen)析某(mou)個相(xiang)位波(bo)形(xing),窗口隨意放大和縮小,也可(ke)以對該段數(shu)據進行頻譜(pu)分(fen)析,分(fen)析放電波(bo)形(xing)的(de)頻譜(pu)含量(liang),使放電波(bo)形(xing)之間更具可(ke)比性,**統計(ji)分(fen)析試(shi)驗數(shu)據,減少試(shi)驗中非穩定性因素(su)對試(shi)驗結果的(de)影響。
本儀(yi)器采用自動或手動記錄保(bao)存試驗數(shu)據和瞬態放(fang)電波形,提(ti)供后(hou)期數(shu)據分析參考(kao)。
WBPCD-4000 TEV在線局放儀技(ji)術參數
技術特性
|
|
通道(dao)數(shu)
|
2/4個電信號(hao)接口,1個外同步接口
|
采(cai)樣率
|
*大200MSa/s
|
采樣精度
|
12bit
|
量程范圍
|
100dB
|
量程切換
|
0-9共(gong)10檔
|
頻(pin)帶范圍
|
1Hz-60MHz
|
本(ben)量程非線性誤差
|
5%
|
檢測靈敏度
|
≥5pC(實驗室條(tiao)件下);≥10pC(現場條件下)
|
圖譜(pu)顯示(shi)方式(shi)
|
二維PPRS顯示、三(san)維PRPD顯示、正弦顯示、統(tong)計、頻譜(AE)5種顯(xian)示
|
電源模(mo)式
|
內置鋰電(dian)池/AC 220V
|
顯(xian)示
|
|
顯(xian)示屏
|
6.5寸 TFT真(zhen)彩色觸摸液晶顯示屏
|
分(fen)辨率(lv)
|
640×480
|
存儲
|
|
物理(li)存儲
|
4GB
|
硬(ying)盤
|
32G固態硬(ying)盤 用于存儲試驗(yan)記(ji)錄(lu)及試驗(yan)數據(ju)
|
接口
|
|
RS232*1
|
用于與(yu)PC機(ji)同(tong)步傳輸接口
|
USB*2
|
可外接鼠標鍵盤,以及外接移動存儲(chu)設備
|
電源模式
|
電池供(gong)電(16.8V鋰電池)+外置(zhi)電源(yuan)(220V AC)
|
電信(xin)號接口(kou)
|
2/4路BNC接口,用于信號(hao)輸入
|
E-Trig接口
|
外同步接口
|
網(wang)口(kou)*1
|
用(yong)于連接網絡(luo)
|
接(jie)地鈕
|
外(wai)部(bu)接(jie)地(di)用
|
通用(yong)說明
|
|
CPU
|
主頻1.6GHz
|
系(xi)統
|
WIN7
|
使用環(huan)境溫度
|
-20℃至60℃
|
存儲環境溫度
|
-20℃至85℃
|
尺寸
|
280*190*80 mm
|
重量(liang)
|
3.5kg
|
配置清單
|
主機
|
用于信號采集、波形顯(xian)示(shi)、數(shu)據處理、存(cun)儲
|
超聲波傳(chuan)感器(qi)
|
用(yong)于測量局部放電產(chan)生(sheng)的超聲波信號
|
檢測頻帶(dai)
|
20~200kHz
|
靈(ling)敏度
|
≤10 pC
|
增益
|
100dB
|
超高頻傳感器(UHF)
|
用于測量GIS中局(ju)部放電(dian)產生的超(chao)高頻信號
|
檢測頻(pin)率
|
300~1500MHz
|
HFCT(高頻電流互感器)
|
用(yong)于(yu)測(ce)量(liang)設(she)備接地(di)線中通過的局部(bu)放電信號
|
檢測波段
|
500kHz~30MHz
|
檢測(ce)靈敏(min)度
|
-100dB/10pC
|
TEV傳感器
|
用于測量開關柜等高壓設備局部放(fang)電、定位
|
信號采集(ji)
|
電(dian)容式
|
檢測頻率
|
3~100MHz
|
測(ce)量范圍
|
-20~60dB/mV
|
聲電組合(he)探測器
|
用(yong)于測量(liang)電(dian)纜接(jie)頭局部放(fang)電(dian)
|
超聲波傳感器
|
用于測量(liang)電纜接(jie)頭局部放電產(chan)生的(de)超聲波信(xin)號(hao)
|
中心頻率
|
40kHz
|
靈(ling)敏(min)度
|
≤10 pC
|
電信(xin)號(hao)傳感器(qi)
|
用于測量(liang)電(dian)纜接頭局部放電(dian)產生的電(dian)磁波信號
|
檢測(ce)頻帶
|
20k~1MHz
|
靈敏度(du)
|
≤10 pC
|
WBPCD-4000 TEV在線局放儀(yi)引用標準
高壓開關設(she)(she)備和控制(zhi)設(she)(she)備標準的共(gong)用技術要求(qiu) DL/T 593
3.6kV~~40.5kV 交流金屬封閉開關設備和(he)控制設備 DL/T 404
3.6kV~~40.5kV 交流金(jin)屬封(feng)閉開關設備和控(kong)制設備 GB 3906
局部放電測量GB/T 7354
電力設備局(ju)部(bu)放(fang)電現(xian)場測量導則(ze) DL/T 417
高電壓試(shi)驗(yan)技術(shu) **部分:一(yi)般試(shi)驗(yan)要求 GB/T 16927.1
高電(dian)壓試驗技術 **部分:測量系(xi)統(tong) GB/T 16927.2
高電壓試驗技術(shu) 第3 部分: 現場試驗的定義及(ji)要求 GB/T 16927.3
WBPCD-4000 TEV在線局(ju)放儀(yi)各種高(gao)壓設備測(ce)量
變壓(ya)器測量
1、超聲(sheng)波法檢測原理
當變(bian)(bian)壓(ya)器(qi)(qi)(qi)內(nei)部產(chan)生放電(dian)信(xin)(xin)號(hao)時(shi),除(chu)產(chan)生放電(dian)脈沖電(dian)流沿(yan)容性回路傳(chuan)輸外,同時(shi)還會激(ji)發出機械波(bo)(超聲(sheng)波(bo))信(xin)(xin)號(hao)通過(guo)變(bian)(bian)壓(ya)器(qi)(qi)(qi)油(you)(you)向(xiang)四周輻射傳(chuan)播。雖然電(dian)力(li)變(bian)(bian)壓(ya)器(qi)(qi)(qi)的(de)結構較為(wei)復(fu)雜(za),但是變(bian)(bian)壓(ya)器(qi)(qi)(qi)的(de)整個器(qi)(qi)(qi)身(shen)內(nei)充(chong)滿了(le)變(bian)(bian)壓(ya)器(qi)(qi)(qi)油(you)(you),而繞組、絕緣材料、支撐、夾件、引線等(deng)部件均浸在油(you)(you)中(zhong),由于(yu)變(bian)(bian)壓(ya)器(qi)(qi)(qi)油(you)(you)為(wei)超聲(sheng)波(bo)的(de)良好(hao)傳(chuan)播媒介,這(zhe)為(wei)在箱壁(bi)外側檢測(ce)局放產(chan)生的(de)超聲(sheng)信(xin)(xin)號(hao)提供了(le)有力(li)條(tiao)件。所以(yi),在變(bian)(bian)壓(ya)器(qi)(qi)(qi)的(de)箱壁(bi)外側安放超聲(sheng)波(bo)傳(chuan)感器(qi)(qi)(qi)可(ke)以(yi)接收到內(nei)部較大的(de)放電(dian)信(xin)(xin)號(hao)。
2、 脈沖電(dian)流法(fa)檢(jian)測原理(HFCT)
由電(dian)力(li)變壓器(qi)的(de)(de)(de)結構所決(jue)定(ding),其繞組(zu)除匝間(jian)電(dian)容外還與鐵(tie)心(xin)之間(jian)存在(zai)幾(ji)百甚至幾(ji)千皮(pi)法的(de)(de)(de)分布(bu)電(dian)容,同時繞組(zu)與油箱(xiang)間(jian)也存在(zai)上(shang)百皮(pi)法的(de)(de)(de)分布(bu)電(dian)容。當(dang)變壓器(qi)的(de)(de)(de)繞組(zu)等(deng)主絕(jue)緣回(hui)路(lu)(lu)中發生局部放電(dian)時,其產生的(de)(de)(de)高頻(pin)(pin)(pin)信(xin)號覆蓋了從幾(ji)十千赫(he)(he)茲到幾(ji)十兆(zhao)赫(he)(he)茲,甚至到千兆(zhao)赫(he)(he)茲,由于(yu)幾(ji)百皮(pi)法電(dian)容對于(yu)幾(ji)百千赫(he)(he)茲以上(shang)的(de)(de)(de)高頻(pin)(pin)(pin)信(xin)號相當(dang)于(yu)通路(lu)(lu),所以放電(dian)信(xin)號就會(hui)向所有(you)(you)與放電(dian)點有(you)(you)容性關系的(de)(de)(de)回(hui)路(lu)(lu)中傳播,其中一條回(hui)路(lu)(lu)必然包括鐵(tie)心(xin)接地(di)回(hui)路(lu)(lu)。所以在(zai)鐵(tie)心(xin)接地(di)線(xian)上(shang)安裝高頻(pin)(pin)(pin)電(dian)流互感器(qi)可有(you)(you)效(xiao)接收(shou)變壓器(qi)內放電(dian)信(xin)號。
WBPCD-4000 TEV在線局(ju)放儀(yi)開(kai)關柜(ju)測(ce)量(liang)
1、開關柜超(chao)聲波法檢測(ce)原理
局部(bu)放(fang)電(dian)(dian)現(xian)象存在多樣性(xing)特(te)征,發生(sheng)放(fang)電(dian)(dian)時,不僅輻射出電(dian)(dian)磁波(bo)(bo)信(xin)(xin)號(hao),也(ye)會(hui)出現(xian)聲(sheng)(sheng)(sheng)波(bo)(bo)發射現(xian)象,局部(bu)放(fang)電(dian)(dian)部(bu)分能量會(hui)以聲(sheng)(sheng)(sheng)波(bo)(bo)的(de)形式向(xiang)周圍傳播(bo)。利用超(chao)聲(sheng)(sheng)(sheng)波(bo)(bo)傳感器(qi)即(ji)可測試這(zhe)些聲(sheng)(sheng)(sheng)脈沖,從而也(ye)可反(fan)映局部(bu)放(fang)電(dian)(dian)的(de)狀(zhuang)況。通(tong)過(guo)測試局部(bu)放(fang)電(dian)(dian)信(xin)(xin)號(hao)中(zhong)聲(sheng)(sheng)(sheng)波(bo)(bo)特(te)征的(de)方法稱為(wei)超(chao)聲(sheng)(sheng)(sheng)波(bo)(bo)法。開關柜內(nei)部(bu)放(fang)電(dian)(dian)過(guo)程中(zhong)會(hui)產生(sheng)聲(sheng)(sheng)(sheng)波(bo)(bo)。放(fang)電(dian)(dian)產生(sheng)的(de)聲(sheng)(sheng)(sheng)波(bo)(bo)的(de)頻譜很寬,可以從幾十(shi)赫茲(zi)到幾十(shi)兆赫茲(zi),其中(zhong)頻率低于20 kHz 的(de)信(xin)(xin)號(hao)能夠被(bei)人(ren)耳(er)聽到,而高(gao)于這一頻率的(de)超(chao)聲(sheng)(sheng)波(bo)信(xin)(xin)號(hao)必須用超(chao)聲(sheng)(sheng)波(bo)傳感器才(cai)能接收到。
2、 地電波法檢測原理(開關柜專用(yong))
當(dang)開關(guan)(guan)(guan)柜的(de)(de)對地(di)(di)(di)絕(jue)緣(yuan)(yuan)部(bu)(bu)分發生(sheng)局部(bu)(bu)放(fang)(fang)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)時,高壓(ya)帶(dai)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)導體對接地(di)(di)(di)金屬(shu)殼(ke)(ke)之間(jian)就(jiu)有少量電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)容(rong)性放(fang)(fang)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)量,這種(zhong)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)容(rong)性放(fang)(fang)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)量的(de)(de)特點是電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)量很小(幾兆分之一庫(ku)倫),持續(xu)時間(jian)很短(幾納秒)。由于放(fang)(fang)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)點在(zai)開關(guan)(guan)(guan)柜內部(bu)(bu),電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)磁波(bo)產生(sheng)的(de)(de)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)壓(ya)脈(mo)沖在(zai)金屬(shu)外(wai)(wai)殼(ke)(ke)內表(biao)面(mian)傳(chuan)播,被(bei)金屬(shu)外(wai)(wai)殼(ke)(ke)所屏(ping)蔽(bi)。如果屏(ping)蔽(bi)層是連(lian)續(xu)的(de)(de),則無法(fa)在(zai)外(wai)(wai)部(bu)(bu)檢(jian)測到(dao)放(fang)(fang)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)信號。實際(ji)上,屏(ping)蔽(bi)層通(tong)(tong)常在(zai)金屬(shu)箱(xiang)體的(de)(de)接縫(feng)處(chu)、氣(qi)體開關(guan)(guan)(guan)的(de)(de)絕(jue)緣(yuan)(yuan)襯墊(dian)、墊(dian)圈的(de)(de)連(lian)接處(chu)、電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)纜絕(jue)緣(yuan)(yuan)終端等(deng)部(bu)(bu)位因(yin)破損而導致不(bu)連(lian)續(xu)。當(dang)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)壓(ya)脈(mo)沖通(tong)(tong)過(guo)這些不(bu)連(lian)續(xu)處(chu)時,將通(tong)(tong)過(guo)這些通(tong)(tong)道(dao)傳(chuan)播出(chu)去,然后沿著金屬(shu)殼(ke)(ke)外(wai)(wai)表(biao)傳(chuan)到(dao)大地(di)(di)(di),同時在(zai)開關(guan)(guan)(guan)柜的(de)(de)金屬(shu)箱(xiang)體上產生(sheng)一個暫態(tai)對地(di)(di)(di)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)壓(ya)(一般在(zai)幾十毫伏到(dao)幾伏,而且時間(jian)只(zhi)能(neng)維持幾納秒),可(ke)以在(zai)運行(xing)中的(de)(de)開關(guan)(guan)(guan)柜金屬(shu)外(wai)(wai)箱(xiang)殼(ke)(ke)上放(fang)(fang)置電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)容(rong)耦合式傳(chuan)感器(qi)來檢(jian)測這個信號。
暫態對(dui)地電壓法檢測部(bu)(bu)位(wei)主(zhu)要是母排(連接(jie)處(chu)、穿墻套管,支撐絕緣(yuan)件(jian)等(deng))、斷路器,CT、PT、電纜接(jie)頭等(deng)部(bu)(bu)件(jian)所對(dui)應到(dao)開(kai)關柜(ju)柜(ju)壁的位(wei)置,這些部(bu)(bu)件(jian)大部(bu)(bu)分位(wei)于(yu)開(kai)關柜(ju)前面(mian)板中(zhong)(zhong)部(bu)(bu)及下部(bu)(bu),后(hou)面(mian)板上部(bu)(bu)、中(zhong)(zhong)部(bu)(bu)及下部(bu)(bu)、側面(mian)板的上部(bu)(bu)、中(zhong)(zhong)部(bu)(bu)及下部(bu)(bu)。開(kai)關柜(ju)暫態對(dui)地電壓法檢測部(bu)(bu)位(wei)可參考圖 5進行測試。
電纜(lan)及附件(jian)測量
1、聲電(dian)組合探(tan)測器檢測原理
電(dian)(dian)纜發生局部放電(dian)(dian)時(shi)產生超(chao)聲(sheng)波(bo)(bo)和電(dian)(dian)磁(ci)波(bo)(bo),并以故障點為(wei)中(zhong)心向四周輻射,其中(zhong)電(dian)(dian)磁(ci)波(bo)(bo)傳播(bo)速度(du)遠大于超(chao)聲(sheng)波(bo)(bo),在(zai)距離(li)故障點一定距離(li)測(ce)量(liang)(liang)時(shi),電(dian)(dian)磁(ci)波(bo)(bo)信(xin)號(hao)(hao)與超(chao)聲(sheng)波(bo)(bo)信(xin)號(hao)(hao)有(you)時(shi)間(jian)差(cha),根(gen)據時(shi)間(jian)差(cha)計算(suan)放電(dian)(dian)位(wei)置(zhi),組(zu)合探測(ce)器利用(yong)這(zhe)一原理,同時(shi)測(ce)量(liang)(liang)電(dian)(dian)磁(ci)波(bo)(bo)信(xin)號(hao)(hao)和超(chao)聲(sheng)波(bo)(bo)信(xin)號(hao)(hao),根(gen)據信(xin)號(hao)(hao)時(shi)間(jian)差(cha)計算(suan)當前故障點所處位(wei)置(zhi)。
2、脈(mo)沖電流法檢測原(yuan)理(li)(HFCT)
在電(dian)(dian)纜中,導線(xian)和金屬屏蔽(bi)(bi)之(zhi)間(jian)由絕(jue)緣材料隔開形成分(fen)布電(dian)(dian)容,該電(dian)(dian)容只有幾百(bai)皮法,對高頻(pin)信號為良導體。因此,高頻(pin)的局放(fang)信號由分(fen)布電(dian)(dian)容對接(jie)地(di)(di)引線(xian)構(gou)成回路傳輸,在電(dian)(dian)纜接(jie)頭屏蔽(bi)(bi)接(jie)地(di)(di)線(xian)上安裝寬頻(pin)帶電(dian)(dian)流互感(gan)器(HFCT)可檢測到放(fang)電(dian)(dian)脈(mo)沖信號,并(bing)能夠(gou)確(que)定(ding)局部放(fang)電(dian)(dian)的量值。
GIS測量
1、UHF檢測原理
UHF檢測法的下限頻率在300MHz以上,上限頻率在1000MHz或以上,因(yin)而可把電(dian)暈放電(dian)引起的干擾(rao)排除掉,其抗(kang)干擾(rao)性能是*優越的。UHF測量將UHF傳感(gan)器(qi)(超高頻傳感(gan)器(qi))凹面部(bu)分緊(jin)貼在GIS盆式絕緣子上,有的GIS盆(pen)式絕緣子(zi)有屏蔽層,但(dan)是(shi)開有測量窗口,將UHF傳感器對準測量窗(chuang)口(kou),就能(neng)取出GIS內部(bu)放電信號。
GIS巡檢(jian)部(bu)位一般取GIS內部(bu)容易放電位置,例(li)如(ru)斷路器、高壓套管下側等,母線可以間隔一段距離檢(jian)測一個點。
2、超聲波檢(jian)測原理(li)
超聲(sheng)波(bo)法(fa)就(jiu)是在(zai)GIS外(wai)部(bu)安(an)放傳(chuan)感器(qi),傳(chuan)感器(qi)的(de)(de)靈(ling)敏(min)范(fan)圍為20KHz-100KHz。用該方(fang)法(fa)可以檢測、識(shi)別(bie)和定位GIS中(zhong)的(de)(de)故(gu)障,而不(bu)需要(yao)預先在(zai)GIS上(shang)安(an)裝內部(bu)耦合(he)器(qi)和傳(chuan)感器(qi)。提(ti)高頻率可降低環(huan)境噪聲(sheng)的(de)(de)影響,這種方(fang)法(fa)的(de)(de)靈(ling)敏(min)度對于(yu)絕(jue)大多數常(chang)見(jian)故(gu)障是比較高的(de)(de)。對于(yu)移動中(zhong)的(de)(de)顆粒,這個方(fang)法(fa)比傳(chuan)統(tong)的(de)(de)局放測量法(fa)和UHF、VHF更優越(yue)。對檢測來自位于(yu)絕(jue)緣子上(shang)的(de)(de)顆粒引起的(de)(de)放電(dian)時,這個方(fang)法(fa)還存在(zai)一些問題(ti),由于(yu)在(zai)環(huan)氧(yang)樹脂(zhi)絕(jue)緣中(zhong)超聲(sheng)波(bo)信號衰(shuai)減(jian)很大,所(suo)以這種方(fang)法(fa)不(bu)能測量環(huan)氧(yang)樹脂(zhi)絕(jue)緣中(zhong)的(de)(de)缺陷(例如氣泡)。
使用超(chao)聲波測(ce)量法測(ce)量GIS局(ju)部放電時,需將超(chao)聲波傳(chuan)感器(qi)探頭(tou)部分(fen)涂抹超(chao)聲耦(ou)合劑(ji),然后將超(chao)聲波傳(chuan)感器(qi)貼到(dao)GIS金屬外殼上,在測(ce)量期間不能震動(dong)傳(chuan)感器(qi),以免(mian)造(zao)成(cheng)測(ce)量數據的(de)不準(zhun)確。
儀器(qi)操作
面板介紹
開(kai)(kai)機:將“電源開(kai)(kai)關”按下,電源指(zhi)示(shi)燈(藍色)長亮,儀器啟動,進(jin)入WINDOWS界面,在桌面有SCJF-2H.EXE快捷方式,雙擊,根據操作指(zhi)示(shi)進(jin)入測量界面。
關機:退出(chu)測量界面,關閉WINDOWS系統(tong),然(ran)后按下(xia)“電(dian)源(yuan)開(kai)關(guan)”,電(dian)源(yuan)指(zhi)示(shi)燈(deng)熄滅(mie),完成關(guan)機。注:一定要關(guan)掉(diao)電(dian)源(yuan)開(kai)關(guan),否(fou)則會造成電(dian)池能量耗盡,影響下(xia)次使用。
充電(dian)(dian):使(shi)用專用充電(dian)(dian)器,將(jiang)充電(dian)(dian)插(cha)頭插(cha)入充電(dian)(dian)口,一次需7個小時。注:當電(dian)池耗盡時,需(xu)充電(dian)20分鐘可開機使用。
軟件操(cao)作說(shuo)明
用(yong)(yong)戶可(ke)以根據(ju)自己的需(xu)求,利用(yong)(yong)系統軟(ruan)件(jian),為每次試(shi)驗建立試(shi)驗檔案,填寫檢測說明信息(xi),保存檢測數據(ju),以便將檢測數據(ju)與檢測信息(xi)對(dui)應起來。
當軟件**次啟動時,系統會出現“試(shi)驗(yan)(yan)設(she)置”對話框,提醒用(yong)戶填(tian)寫試(shi)驗(yan)(yan)信息,同時可以對試(shi)驗(yan)(yan)列(lie)表進行查(cha)看和刪除某個(ge)試(shi)驗(yan)(yan),當單擊試(shi)驗(yan)(yan)列(lie)表中某個(ge)試(shi)驗(yan)(yan)時,試(shi)驗(yan)(yan)信息區將顯(xian)示對應(ying)試(shi)驗(yan)(yan)信息。
如果你點擊取消按鈕,不(bu)建(jian)立(li)自己的試驗檔案,系統(tong)軟件也可(ke)以快速建(jian)立(li)默認數據庫quik_test.db3,保證完成試驗數據的(de)存儲。
軟件(jian)會在硬盤D:TESTV2.X\test中(zhong)建(jian)立存儲目錄(lu)以保存數(shu)據,例(li)如:
試驗(yan)名稱為: TEST1
則 檢測數據存儲路(lu)徑為:D:TESTV2.0\test\test1
所(suo)有(you)的(de)檢測原始(shi)數(shu)據都以(yi)二進制(zhi)方式保(bao)存以(yi)節省(sheng)存儲空間,所(suo)有(you)的(de)記錄數(shu)據都存儲在(zai)SQLite數據庫中,以(yi)備生成報告使用。
利用本(ben)系統進行(xing)檢測(ce)(ce)檢測(ce)(ce)數據都(dou)存儲在(zai)硬(ying)盤(pan)中,也可以導出到(dao)PC機進(jin)行備份。歷史(shi)數(shu)據可(ke)以被加載(zai)入系統進(jin)行追蹤分(fen)析。
試驗設置對話框:
當上述參數均設(she)置完畢后(hou),點(dian)擊開始試驗(yan)進行試驗(yan)。
系統(tong)軟件主窗(chuang)口
系統(tong)狀態參數
當(dang)系統軟件啟動之后,狀態欄就會顯示當(dang)前系統狀態,如記(ji)錄(lu)存儲狀況(kuang)、系統時間、運行狀況(kuang)、觸發(fa)方(fang)式以(yi)及設備(bei)電(dian)池電(dian)量。
水平:當前窗(chuang)口每格(ge)顯(xian)示(shi)時間長度;
豎直:
(1)當前操作通道選(xuan)擇(ze):如選(xuan)擇(ze)“CH1”當前所有參(can)數設(she)置對象為1通(tong)道。
(2)通道(dao)打開/關閉:可將選種通道(dao)打開/關閉。
(3)通道(dao)(dao)供(gong)(gong)電(dian)選擇:標記該選項可對所選通道(dao)(dao)供(gong)(gong)電(dian);
注:當外接(jie)有源傳(chuan)感器(qi)時把“供電”對話框選(xuan)(xuan)中(zhong),未接(jie)有源傳(chuan)感器(qi)的通道“供電”對話框選(xuan)(xuan)擇空(kong)白狀態;
(4) 通道(dao)量(liang)程設置:更改(gai)當(dang)前通道(dao)量(liang)程;
(5)校(xiao)正參數設置:通(tong)過標準源校(xiao)準儀器;
(6)校正(zheng)(zheng)按(an)鈕(niu):在儀器暫停情況下按(an)下執行校正(zheng)(zheng)功(gong)能(neng);
觸發:
觸(chu)發模式:提示當前(qian)觸(chu)發方(fang)(fang)式,從而保(bao)證系統根(gen)據觸(chu)發方(fang)(fang)式正確的使用。
觸發方式:可選擇(ze)自動觸發、單次(ci)觸發;
電(dian)池電(dian)量:提示當(dang)前電(dian)池剩(sheng)(sheng)余電(dian)量,當(dang)剩(sheng)(sheng)余電(dian)量小(xiao)于5%時,系(xi)統會發出嘀嘀嘀嘀報警聲,提(ti)示用戶(hu)應連接適配器(qi)充電,或保存數據關閉系(xi)統,防止因電池沒(mei)電關機導(dao)致試驗數據丟(diu)失。
顯(xian)示(shi)界面:
顯(xian)示(shi)界面為獨立(li)四(si)通道顯(xian)示(shi),可同時顯(xian)示(shi)波形、放電(dian)量值。
設置界面:
在主顯示窗口上方有一排設置選(xuan)項
(1)退出功能鍵
退(tui)出按鍵,當實驗完(wan)畢時單擊此按鍵退(tui)出試驗界面
(2)單位(wei)轉(zhuan)換(huan)按鍵
|
顯(xian)示單位(wei)轉換功(gong)能,顯(xian)示單位(wei)在(zai)mV和(he)dB之間轉換
|
(3)自動定位按(an)鍵
自動(dong)定位功能
(4)暫(zan)停/開始按鍵
開始/暫停功能
(5)保存功(gong)能
錄波和保(bao)存圖片(pian)功能
(6)頻域分析功(gong)能(neng)
將當前所選通道時域(yu)波形(xing)(xing)轉換為頻域(yu)波形(xing)(xing)
(7)屏幕鍵(jian)盤
調(diao)取軟件盤
(8)三(san)維圖顯示(shi)功(gong)能
N-Q-φ三維圖
4. 局(ju)部放電檢測儀配置
該設(she)備配(pei)置主機可(ke)共用不(bu)(bu)同傳感(gan)器(qi)可(ke)測量(liang)不(bu)(bu)同設(she)備,不(bu)(bu)同傳感(gan)器(qi)使(shi)用方法不(bu)(bu)同,其主要區(qu)別(bie)是(shi)是(shi)否需要供電,區(qu)別(bie)如(ru)下表(biao):
序號
|
巡檢設備名稱
|
所需傳感器
|
是否供(gong)電
|
備注
|
1
|
變壓(ya)器
|
超聲波傳(chuan)感器
|
供(gong)電
|
接(jie)觸式
|
寬頻帶電(dian)流互感器
|
不(bu)供
|
|
2
|
開(kai)關(guan)柜
|
TEV傳(chuan)感器
|
供電
|
|
超聲波(bo)傳感(gan)器
|
供電(dian)
|
非接觸式
|
3
|
電纜頭
|
聲電(dian)組合探測器
|
供電
|
|
4
|
GIS
|
超聲波傳感器
|
供電(dian)
|
接觸式
|
UHF傳(chuan)感器(qi)
|
供電
|
|