一、WBYD2000變頻串并聯諧振變壓器基本原理
耐(nai)壓(ya)試(shi)驗(yan)是利用(yong)電(dian)(dian)(dian)抗(kang)器的電(dian)(dian)(dian)感與被試(shi)品(pin)(pin)電(dian)(dian)(dian)容組成LC串聯回路,調(diao)節變頻電(dian)(dian)(dian)源輸出的電(dian)(dian)(dian)壓(ya)頻率(lv),在被試(shi)品(pin)(pin)上獲(huo)得高電(dian)(dian)(dian)壓(ya),是當前高電(dian)(dian)(dian)壓(ya)試(shi)驗(yan)的一種新方法,深受專(zhuan)家好評,在國內外已經得到廣泛的使用(yong)。
根據諧(xie)振原(yuan)理,我(wo)們知道當電抗(kang)(kang)器(qi)L的(de)感抗(kang)(kang)值Xl與回(hui)(hui)路(lu)(lu)中的(de)容抗(kang)(kang)值Xc相等時(shi),回(hui)(hui)路(lu)(lu)達到諧(xie)振狀態,此時(shi)回(hui)(hui)路(lu)(lu)中僅回(hui)(hui)路(lu)(lu)電阻R消耗(hao)有(you)功功率(lv),而(er)無功功率(lv)則在(zai)電抗(kang)(kang)器(qi)與試品電容之間來回(hui)(hui)振蕩,從而(er)在(zai)試品上產生(sheng)高(gao)壓(ya)。
二、WBYD2000變頻串并聯諧振變壓器系統構成
全套試驗(yan)系(xi)統由調頻電源主機、電抗器(qi)、分壓器(qi)、激勵變壓器(qi)和補償(chang)電容(rong)器(qi)(可(ke)選(xuan)器(qi)件)組成,接入(ru)被試品后組成一個(ge)諧振系(xi)統進行交流耐壓實(shi)驗(yan)。
主機: 就是(shi)一臺幅(fu)值和(he)頻率可調的正(zheng)弦(xian)波交流調頻電(dian)源,給諧振回路提供激勵源,同時提供電(dian)壓顯(xian)(xian)示、電(dian)流顯(xian)(xian)示、計時、保護、報(bao)警等功能。
電抗(kang)器:就(jiu)是一個大電感(gan)線圈(quan),與被試(shi)(shi)品(相當于電容)構成回路,可配置(zhi)電抗(kang)器多節電抗(kang)器,使用時(shi)通(tong)過不(bu)同的(de)串聯、并聯組合、實(shi)現不(bu)同的(de)電感(gan)量以適用不(bu)同的(de)試(shi)(shi)驗條件。
分(fen)壓(ya)(ya)器:內部(bu)通(tong)過電(dian)(dian)容器分(fen)壓(ya)(ya),從試(shi)品上高電(dian)(dian)壓(ya)(ya)分(fen)得低電(dian)(dian)壓(ya)(ya)供主機測量、控制使用。
勵磁變壓器(qi):隔離主機(ji)電源與(yu)諧振回路電源,并升高主機(ji)的輸出電壓。
補(bu)償電容(rong)器:當試(shi)品(pin)電容(rong)量很(hen)小時,如果要(yao)實(shi)現系統諧(xie)振可(ke)能要(yao)求的電源頻率(lv)超(chao)出試(shi)驗標準的規定,可(ke)在試(shi)品(pin)上并(bing)聯一(yi)個(ge)補(bu)償電容(rong),以實(shi)現試(shi)驗要(yao)求,稱(cheng)此電容(rong)器為補(bu)償電容(rong)器。
三、WBYD2000變頻串并聯諧振變壓器主要技術性能
功率電(dian)源電(dian)壓:AC380V±10%、50Hz;
儀(yi)器(qi)電源:220V±10%、50Hz;
諧(xie)振輸出容(rong)量(liang):200kVA;
儀器(qi)額(e)定電壓:0~200kV;
輸(shu)出頻率(lv)范圍(wei):30~300Hz;
輸出電壓波形:正弦波,波形畸變率<0.5%;
頻率(lv)調節靈敏度(du):0.1Hz,不穩定度(du)≤0.05%;
系統噪聲:≤60db;
9、系統測量精度(du):<1級;
10.輸出(chu)電壓不穩定:<0.5%;
11.保護響(xiang)應時間(jian):1us;
12.電感非線性度:≤0.05%;;
13.滿功(gong)率輸(shu)出下(xia),連續工作時間(jian)為60min
14.環境溫度:-15℃~+50℃;
15.相對(dui)濕度:≤90%RH;
16.海拔高度:≤2000米。
四、WBYD2000變頻串并聯諧振變壓器面板及部件名稱
五、WBYD2000變頻串并聯諧振變壓器操作步驟
1、正確連(lian)線(xian),檢查(cha)無(wu)誤后方(fang)可送電。
必要時工作電(dian)源的跳過現場漏電(dian)保安器,以免不(bu)必要的跳閘。
2、打開電(dian)源(yuan)開關,主機開始工作,液晶(jing)屏顯(xian)示版(ban)(ban)權頁(ye),該頁(ye)標明本裝(zhuang)置的軟件版(ban)(ban)本號。
觸按確認鍵,進入系(xi)統(tong)菜單(dan)(dan),該(gai)主(zhu)菜單(dan)(dan)下(xia)有(you):試(shi)驗方案、開始試(shi)驗、試(shi)驗幫助、系(xi)統(tong)設置、實用工具(ju)和試(shi)驗記錄等六個子菜單(dan)(dan)項。
3、 系統設(she)(she)置(zhi)菜(cai)單(dan)下有電(dian)(dian)抗器(qi)電(dian)(dian)感、日(ri)期(qi)時間設(she)(she)置(zhi)和(he)采樣(yang)系數設(she)(she)置(zhi)等(deng)三個子菜(cai)單(dan)項(xiang)(xiang)。按上(shang)下鍵(jian),上(shang)下移動光標系統參(can)數設(she)(she)置(zhi)菜(cai)單(dan)項(xiang)(xiang),觸按確定(ding)鈕后,進入(ru)系統參(can)數設(she)(she)置(zhi)菜(cai)單(dan),可以(yi)分別設(she)(she)定(ding)電(dian)(dian)抗器(qi)的電(dian)(dian)感—H、-年-月-日(ri)、-時-分-秒和(he)電(dian)(dian)壓和(he)電(dian)(dian)流(liu)的采樣(yang)系數也就是采樣(yang)倍率,設(she)(she)定(ding)完(wan)成(cheng)后,觸按返還(huan)鍵(jian)返回上(shang)**菜(cai)單(dan)。
電抗(kang)器電感量的設定(ding):按(an)(an)確(que)定(ding)鍵(jian)選擇(ze)到此項,按(an)(an)左右鍵(jian)移動光標需(xu)要改變的數位,按(an)(an)上下鍵(jian)改變數值(zhi),達到所要達到的數值(zhi)按(an)(an)確(que)定(ding)鍵(jian)確(que)認。
日期時(shi)間的(de)設(she)定:按確(que)定鍵(jian)選擇(ze)到此項,按左右鍵(jian)移動光標需要改變(bian)的(de)數位,按上(shang)下(xia)鍵(jian)改變(bian)數值(zhi),按照所(suo)要設(she)置的(de)年月日時(shi)間數值(zhi)按確(que)定鍵(jian)確(que)認。
采樣系數的設(she)定(ding):按確定(ding)鍵選擇到高壓/電流(liu)采樣系數項(xiang),此項(xiang)為(wei)電壓或電流(liu)采樣倍率的設(she)定(ding)。一(yi)般(ban)出廠前設(she)定(ding)好了(le)。如(ru)需修改,要輸入(ru)密碼(ma)。(密碼(ma)廠家與設(she)備一(yi)起提供一(yi)般(ban)設(she)定(ding)為(wei):188888)
警告:系(xi)(xi)統(tong)默認上一(yi)次電(dian)(dian)(dian)抗(kang)器電(dian)(dian)(dian)感、日期時間(jian)和采樣(yang)系(xi)(xi)數(shu)設(she)(she)定(ding)值。如果需改(gai)變要重新設(she)(she)定(ding)。電(dian)(dian)(dian)抗(kang)器電(dian)(dian)(dian)感量(liang)(liang)設(she)(she)定(ding)值與(yu)實際使(shi)用的(de)電(dian)(dian)(dian)抗(kang)器電(dian)(dian)(dian)感量(liang)(liang)不(bu)對,會導(dao)致試驗報告中的(de)被試品電(dian)(dian)(dian)容量(liang)(liang)不(bu)準(zhun)。其(qi)他并不(bu)會影(ying)響。采樣(yang)系(xi)(xi)數(shu)設(she)(she)置不(bu)正確(que),會導(dao)致顯示電(dian)(dian)(dian)壓電(dian)(dian)(dian)流不(bu)準(zhun)將很有可(ke)能(neng)會對被試品或試驗設(she)(she)備造成損壞。
4、試(shi)(shi)驗方案菜單(dan)(dan)下(xia)有預(yu)置(zhi)保護(hu)電(dian)流(liu)、找(zhao)(zhao)頻(pin)(pin)起(qi)(qi)始(shi)(shi)頻(pin)(pin)率(lv)、找(zhao)(zhao)頻(pin)(pin)結束頻(pin)(pin)率(lv)、預(yu)定(ding)起(qi)(qi)始(shi)(shi)功(gong)率(lv)四個子菜單(dan)(dan)項,分別設定(ding)本次試(shi)(shi)驗的(de)保護(hu)電(dian)流(liu)、找(zhao)(zhao)頻(pin)(pin)起(qi)(qi)始(shi)(shi)頻(pin)(pin)率(lv)、找(zhao)(zhao)頻(pin)(pin)結束頻(pin)(pin)率(lv)、輸出起(qi)(qi)始(shi)(shi)功(gong)率(lv),全部設定(ding)完(wan)成后,觸(chu)按(an)返(fan)還鍵進入預(yu)置(zhi)試(shi)(shi)驗電(dian)壓和預(yu)置(zhi)試(shi)(shi)驗時間(jian)設置(zhi)菜單(dan)(dan)。
可以分3段時(shi)(shi)間(jian)設(she)置試驗(yan)電壓和試驗(yan)時(shi)(shi)間(jian), 實(shi)際試驗(yan)時(shi)(shi),若設(she)定(ding)為(wei)自(zi)(zi)動試驗(yan), 裝(zhuang)置將按設(she)定(ding)的3段電壓及(ji)時(shi)(shi)間(jian),按順序分別加壓, 全部(bu)完(wan)成后自(zi)(zi)動退出.
如果(guo)**段電(dian)壓(ya)設(she)為0, 或(huo)時間設(she)為0, 那么(me)執(zhi)行(xing)完**段試驗電(dian)壓(ya)加壓(ya)后退出試驗, 只加壓(ya)**段設(she)定的電(dian)壓(ya).
如果第三(san)段電壓(ya)設(she)為(wei)0, 或時間設(she)為(wei)0, 不執行(xing)第三(san)段加壓(ya).
試(shi)驗(yan)方(fang)案設(she)置的設(she)定(ding):在試(shi)驗(yan)電壓(ya)項中,按確(que)定(ding)單鈕(niu),移動左右(you)光(guang)標到(dao)需要改變(bian)的數位,按上下(xia)單鈕(niu)以改變(bian)當(dang)前(qian)數位的數值大小,觸(chu)按返回鈕(niu)完成(cheng)(cheng)當(dang)前(qian)數位的數值設(she)定(ding),依(yi)次(ci)選擇下(xia)一項數值的設(she)定(ding),直至分別完成(cheng)(cheng)試(shi)驗(yan)時間、起始頻率、起始功率的設(she)置,方(fang)可完成(cheng)(cheng)本(ben)次(ci)試(shi)驗(yan)的試(shi)驗(yan)方(fang)案設(she)置的設(she)定(ding)。
出廠默認值:試驗(yan)電壓(ya) 20kV、加壓(ya)時間 2min、激(ji)勵強度(du) 2%、輸(shu)出電流(liu)20A、頻率范圍30-300Hz。
5、實(shi)用工具菜單下有
頻(pin)率(lv)計(ji)算:在實驗(yan)前可對諧振頻(pin)率(lv)進行計(ji)算。只需輸(shu)入具(ju)體(ti)參與(yu)試驗(yan)的電感、電容(rong)值并按確定鍵試驗(yan)頻(pin)率(lv)即直(zhi)接生成。
6、開始試(shi)驗菜(cai)單(dan)下有自動試(shi)驗模式和手動試(shi)驗模式兩種子菜(cai)單(dan)可供選擇。
按(an)確(que)認鍵進入所選試驗步驟(zou).
自(zi)動(dong)(dong)試驗模(mo)式的(de)操作:選中(zhong)自(zi)動(dong)(dong)試驗模(mo)式后,觸按菜單(dan)鈕進入正在自(zi)動(dong)(dong)尋找諧振點(dian)菜單(dan)項(xiang),裝置(zhi)在設(she)定的(de)頻率(lv)(lv)范圍(wei)內(nei)自(zi)動(dong)(dong)尋找諧振點(dian)(如果被試品電(dian)容C和電(dian)抗器電(dian)感(gan)L的(de)實際諧振頻率(lv)(lv)不在設(she)定的(de)頻率(lv)(lv)范圍(wei)內(nei),將找不到諧振點(dian),此(ci)時(shi)根據需(xu)要調(diao)整頻率(lv)(lv)范圍(wei)或(huo)調(diao)整被試品回路的(de)LC參數)。當找到諧振點(dian)時(shi),會有聲(sheng)音提(ti)示。
找(zhao)到(dao)諧(xie)振點后,裝(zhuang)(zhuang)置自(zi)動進(jin)入正在自(zi)動升(sheng)壓(ya)(ya)菜單項,當(dang)升(sheng)到(dao)試(shi)驗電壓(ya)(ya)設定的電壓(ya)(ya)時,裝(zhuang)(zhuang)置停止加壓(ya)(ya)。
當(dang)裝置升到(dao)試(shi)(shi)驗(yan)(yan)(yan)電(dian)壓(ya)(ya)(ya)設(she)(she)定的電(dian)壓(ya)(ya)(ya)時,設(she)(she)備停止加(jia)(jia)壓(ya)(ya)(ya),自(zi)動進入正在加(jia)(jia)壓(ya)(ya)(ya)試(shi)(shi)驗(yan)(yan)(yan)菜(cai)單項(xiang),并(bing)自(zi)動記錄試(shi)(shi)驗(yan)(yan)(yan)的加(jia)(jia)壓(ya)(ya)(ya)時間,當(dang)加(jia)(jia)壓(ya)(ya)(ya)時間到(dao)達設(she)(she)定時間時,設(she)(she)備逐步降壓(ya)(ya)(ya)退出試(shi)(shi)驗(yan)(yan)(yan),完(wan)成本(ben)次(ci)試(shi)(shi)驗(yan)(yan)(yan),進入試(shi)(shi)驗(yan)(yan)(yan)結束菜(cai)單項(xiang)。并(bing)可選擇保存試(shi)(shi)驗(yan)(yan)(yan)數據或打印試(shi)(shi)驗(yan)(yan)(yan)數據。
試驗時間的(de)一(yi)行顯示(shi)(shi)(shi)末端,會顯示(shi)(shi)(shi)[一(yi)段]或(huo)[二段]或(huo)[三段]字(zi)樣,表示(shi)(shi)(shi)當前正在進行的(de)加壓(ya)試驗是(shi)預置的(de)一(yi)段,二段或(huo)三段.
手動(dong)試(shi)(shi)驗(yan)(yan)(yan)(yan)模(mo)式的(de)(de)(de)操作:選中手動(dong)試(shi)(shi)驗(yan)(yan)(yan)(yan)模(mo)式后觸按確定鈕(niu),進入正(zheng)在(zai)試(shi)(shi)驗(yan)(yan)(yan)(yan)菜單項;手動(dong)按調頻(pin)(pin)(pin)鈕(niu),對應(ying)的(de)(de)(de)光標(biao)隨(sui)之改(gai)變到輸出(chu)頻(pin)(pin)(pin)率(lv)項,可以通過上下(xia)左右鍵(jian)改(gai)變頻(pin)(pin)(pin)率(lv)大小使其試(shi)(shi)驗(yan)(yan)(yan)(yan)電壓逐(zhu)步升(sheng)高,當升(sheng)到*高電壓時,繼續向(xiang)上或向(xiang)下(xia)調整(zheng)頻(pin)(pin)(pin)率(lv)按鈕(niu),直(zhi)至試(shi)(shi)驗(yan)(yan)(yan)(yan)電壓開始下(xia)降;這時反調頻(pin)(pin)(pin)率(lv),試(shi)(shi)驗(yan)(yan)(yan)(yan)電壓又逐(zhu)步回升(sheng),上下(xia)回調頻(pin)(pin)(pin)率(lv),從(cong)頻(pin)(pin)(pin)率(lv)的(de)(de)(de)高位到低(di)位逐(zhu)位調整(zheng)*高電壓值時的(de)(de)(de)頻(pin)(pin)(pin)率(lv)就是當前的(de)(de)(de)諧(xie)振頻(pin)(pin)(pin)率(lv)。
找到(dao)諧(xie)振點后,手動(dong)按電(dian)壓(ya)鈕,光標到(dao)了輸出功率,隨之按上下鍵增加(jia)輸出功率,試(shi)(shi)(shi)驗電(dian)壓(ya)也逐步(bu)升高,當(dang)(dang)升到(dao)試(shi)(shi)(shi)驗電(dian)壓(ya)設(she)定電(dian)壓(ya)值時,裝置停止加(jia)壓(ya),并有屏幕顯示(shi)(shi)提(ti)示(shi)(shi)和(he)聲音提(ti)示(shi)(shi);自動(dong)進入正在(zai)加(jia)壓(ya)試(shi)(shi)(shi)驗菜單(dan)項,并自動(dong)記錄試(shi)(shi)(shi)驗的加(jia)壓(ya)時間,當(dang)(dang)到(dao)達(da)加(jia)壓(ya)時間設(she)定時間時,設(she)備(bei)逐步(bu)降壓(ya)退出試(shi)(shi)(shi)驗,完成本次試(shi)(shi)(shi)驗,進入試(shi)(shi)(shi)驗結束菜單(dan)項。
注意:在(zai)調(diao)(diao)(diao)節(jie)頻(pin)率調(diao)(diao)(diao)整鈕的(de)過(guo)程中(zhong),觸(chu)按(an)左右鈕,可以(yi)改變頻(pin)率調(diao)(diao)(diao)節(jie)的(de)速度(du)(du)實(shi)現(xian)粗細調(diao)(diao)(diao)的(de)切(qie)換(huan)。在(zai)調(diao)(diao)(diao)節(jie)電壓(ya)(ya)調(diao)(diao)(diao)整鈕的(de)過(guo)程中(zhong),向(xiang)下觸(chu)按(an)左右鈕,可以(yi)改變電壓(ya)(ya)的(de)升降的(de)速度(du)(du)實(shi)現(xian)粗細調(diao)(diao)(diao)的(de)切(qie)換(huan)。觸(chu)按(an)調(diao)(diao)(diao)頻(pin)、調(diao)(diao)(diao)壓(ya)(ya)鈕,實(shi)現(xian)調(diao)(diao)(diao)頻(pin)與調(diao)(diao)(diao)壓(ya)(ya)間的(de)切(qie)換(huan)。
7、進(jin)入試驗記錄查詢菜(cai)單項(xiang),查詢以往和當(dang)前(qian)試驗數(shu)據(ju)。選擇(ze)上下鍵翻看前(qian)一(yi)組(zu)數(shu)據(ju)后一(yi)組(zu)數(shu)據(ju);選擇(ze)左右鍵可選擇(ze)打(da)印或(huo)刪(shan)除(chu)當(dang)前(qian)頁的內容。
125/456為試驗(yan)數(shu)據(ju)(ju)庫指針(zhen),分(fen)子是試驗(yan)數(shu)據(ju)(ju)的在數(shu)據(ju)(ju)庫的順序數(shu),分(fen)母(mu)是當前的數(shu)據(ju)(ju)總數(shu),*多可(ke)儲(chu)存999組試驗(yan)數(shu)據(ju)(ju)。
8、裝置和試(shi)驗(yan)狀態菜單提示:設(she)備(bei)(bei)的(de)(de)使用和升壓(ya)和耐壓(ya)試(shi)驗(yan)過程中,如果出現(xian)影響試(shi)驗(yan)設(she)備(bei)(bei)、被試(shi)驗(yan)設(she)備(bei)(bei)以及操作人的(de)(de)**情(qing)況,設(she)備(bei)(bei)可能出現(xian)自動保護(hu)轉臺,并在屏(ping)幕有相(xiang)應的(de)(de)提示。
不(bu)(bu)能諧(xie)(xie)振:如果諧(xie)(xie)振點不(bu)(bu)在諧(xie)(xie)振頻率設(she)置的(de)范圍內;系(xi)統連(lian)線不(bu)(bu)正(zheng)確等現(xian)象(xiang),裝置將找不(bu)(bu)到諧(xie)(xie)振點,這時裝置和試驗狀(zhuang)態菜單中(zhong)的(de)不(bu)(bu)能諧(xie)(xie)振項被反白并(bing)閃爍(shuo)。
輸出(chu)保(bao)(bao)護(hu):如(ru)果(guo)裝置的(de)電源輸出(chu)電流大于輸出(chu)保(bao)(bao)護(hu)設定的(de)電流值,裝置自動保(bao)(bao)護(hu),這時裝置和試驗狀態菜單中的(de)輸出(chu)保(bao)(bao)護(hu)項被反白(bai)并閃爍。
試(shi)驗(yan)中止:如果在試(shi)驗(yan)升(sheng)壓(ya)或加壓(ya)過程出現(xian)閃(shan)絡現(xian)象,裝置自動(dong)保(bao)護,這(zhe)時裝置和(he)試(shi)驗(yan)狀態(tai)菜(cai)單中的(de)輸出保(bao)護項被反白并閃(shan)爍。
9、試(shi)驗幫助(zhu)內容包(bao)括五(wu)大項分別為:1.版(ban)本信(xin)息2.接線示意3.使(shi)用說(shuo)明4.常見問(wen)題(ti)5.參考資料.如(ru)常見問(wen)題(ti)FAQ分五(wu)幅畫面(mian)顯示、各(ge)種被試(shi)品電力電纜、變壓器、發(fa)電機電容參數的查詢:
接線示意圖:
10、設備出廠(chang)參(can)數設置是生產廠(chang)家(jia)的(de)出廠(chang)設置參(can)術和(he)校(xiao)驗(yan)參(can)數,不適當的(de)設置和(he)修改(gai)會影響設備性能和(he)高(gao)壓(ya)試驗(yan)的(de)**性,未經廠(chang)家(jia)授(shou)權密碼,無法(fa)修改(gai)。
警(jing)告:正(zheng)常試(shi)驗(yan)狀態下,按返(fan)回鍵即可中止(zhi)試(shi)驗(yan)。中止(zhi)或(huo)結(jie)束試(shi)驗(yan)后,應分(fen)離刀(dao)閘切斷電源(yuan)。在升壓(ya)或(huo)加壓(ya)過程中,非緊急情況,不要按下急停鍵。
六(liu)、本說明(ming)書的專(zhuan)屬名詞的定義(yi)
自動試驗:高(gao)壓試驗全過(guo)程由主(zhu)機按程序和(he)預(yu)置(zhi)參數自動完成(cheng)。
自(zi)動調諧(xie):調諧(xie)由(you)主機按程序自(zi)動完成,升(sheng)壓手動完成。
手(shou)動(dong)試(shi)驗(yan):尋找諧(xie)振點和升壓均為手(shou)動(dong),通過面板旋(xuan)鈕完成(cheng)。
系(xi)統參數(shu)(shu)設置(zhi)是指(zhi)對設備(bei)部件參數(shu)(shu)的設置(zhi)。
試(shi)驗參數(shu)設置是指對(dui)試(shi)驗過程參數(shu)的(de)設置。
試驗模式(shi)選擇(ze)是指對試驗模式(shi)的(de)選擇(ze)。
試(shi)驗(yan)結(jie)果查(cha)詢是指對(dui)試(shi)驗(yan)數(shu)據(ju)的查(cha)詢。
分壓器變比(bi)是指對分壓器的(de)分壓比(bi)設置(zhi)。
電(dian)(dian)抗器電(dian)(dian)感是指對(dui)電(dian)(dian)抗器電(dian)(dian)抗值的(de)設置。
激勵變變比(bi)是指對勵磁變壓器的變比(bi)設置。
設置電壓是(shi)高壓試驗(yan)時的保(bao)護電壓設置。
試(shi)驗(yan)電(dian)(dian)壓(ya)(ya)是高(gao)壓(ya)(ya)試(shi)驗(yan)時的試(shi)驗(yan)電(dian)(dian)壓(ya)(ya)。
加壓(ya)(ya)時間是施(shi)加試(shi)驗電壓(ya)(ya)的時間。
激勵(li)強(qiang)度(du)是指主(zhu)機電源輸出的大(da)小。
輸出電流(liu)是主機電源的輸出電流(liu)。
頻(pin)率范圍(wei)(wei)是試驗的頻(pin)率范圍(wei)(wei)。
自動(dong)試(shi)驗模式是指試(shi)驗過程全部自動(dong)完成。
自(zi)動調諧模式是指(zhi)自(zi)動尋找(zhao)諧振點后,手動加壓(ya)完成(cheng)試驗。
手動試驗模式全部由人工完(wan)成試驗過程。
未接地(di)線(xian)主機電源為接地(di)。
不(bu)能諧振未(wei)能找到諧振點。
輸出保護主機電(dian)(dian)(dian)源輸出電(dian)(dian)(dian)流大(da)于整(zheng)定(ding)電(dian)(dian)(dian)流。
試驗中止指(zhi)在(zai)升壓(ya)或加壓(ya)過程裝置自動保(bao)護。
設備(bei)出(chu)廠參數設置(zhi)是(shi)廠家對設備(bei)有關參數的設置(zhi)。
確認(ren)(ren)鍵:確認(ren)(ren)當前操(cao)作。
返回鍵(jian):返回上**菜單。
七(qi)、變頻電源技術參數(shu):
1.額(e)定輸(shu)出容量:15kvA;
2.儀器電源(yuan):220v±10% 50Hz;
功(gong)率電源:380v±10% 50Hz;
3.額(e)定輸(shu)入(ru)電流:39.5A;
4.額(e)定輸出(chu)電壓(ya):0-340v可調、單(dan)相、輸出(chu)電壓(ya)不穩定度0.05%;
5.額定輸(shu)出電流(liu):44A;
6.頻率調節范圍:25~320Hz;
7.額定容量下(xia)(xia)連續(xu)運行為(wei)規定工作時間(jian)下(xia)(xia)*高溫升(sheng)≤60K;
8.顯示以下參(can)數:
a.經變頻輸出(chu)的頻率(lv)、電壓(ya)、電流;
b.過壓保(bao)護電壓值,并可任意整定,當成套裝置的輸出(chu)電壓值達到(dao)保(bao)護整定時,可自動(dong)切除(chu)成套裝置;
c.過流保護(hu):當(dang)調頻電(dian)源(yuan)的(de)輸出電(dian)流達到(dao)保護(hu)整定值時,可自動切除成(cheng)套裝置(zhi);
d.擊穿保(bao)護(hu):當高壓側(ce)發生對地閃絡(luo)時,可自動切(qie)除成套裝置,裝置帶有隔離裝置,可確(que)保(bao)設備和(he)人身不受損害;
e.具有全(quan)電(dian)壓輸出保護,在調壓過(guo)程中,一旦調壓失控(kong),調頻(pin)電(dian)源立即閉鎖;
9.可實現以(yi)下操作:
a.頻率的調(diao)節(jie),上升和下降(jiang)頻率調(diao)節(jie)分粗調(diao)和細調(diao)兩種(zhong),并可自動尋(xun)找(zhao)試(shi)驗諧(xie)振點,保證諧(xie)振頻率在整個(ge)試(shi)驗過(guo)程中(zhong)不發生漂移(yi);
b.帶有設置電(dian)壓、設置時(shi)間,電(dian)壓自動上升到設置值而停止并自動計時(shi);
c.帶有各種(zhong)保(bao)護(hu)功能的整定(ding)按鈕(niu),可在面板上對各種(zhong)保(bao)護(hu)值進行整定(ding);
d.帶有手動試(shi)驗功能和自動試(shi)驗功能;
e.帶(dai)有試驗(yan)數據打印功能。
八、勵磁變壓器技術(shu)參(can)數:
1.結(jie)構形(xing)式:干式;
2.額(e)定(ding)容量:15kVA;
3.輸入電壓(ya):0~340V;
4.輸出電壓(ya):四組并聯(lian)3.75KV;四組串(chuan)聯(lian)15KV;二串(chuan)二并7.5KV;
5.輸(shu)出電(dian)流:四組(zu)并(bing)聯(lian)4A;四組(zu)串(chuan)聯(lian)1A;二串(chuan)二并(bing)2A;
6.工作頻率范圍:30~300Hz;
勵磁變壓器的接線(xian)端子,如圖所(suo)示:
1.輸出端尾—與接地(di)端連接。
2.輸出端頭—與(yu)電抗器連(lian)接。
3.接(jie)地(di)端—與變頻(pin)電(dian)源、分(fen)壓器及被試品共同接(jie)地(di)。
4.輸(shu)入(ru)端—接調頻(pin)電源功率輸(shu)出端。
九、諧振電抗器技術參(can)數(shu):
額(e)定容(rong)量:55KVA;
額定電(dian)壓:55kV;
額(e)定(ding)電(dian)流:1.5A;
電(dian) 感 量(liang):160H;
品質因(yin)數:Q≥30
采(cai)用環氧干式。
7.接線端了(le)如圖所示:
a.高(gao)壓側接(jie)線端(duan)子—與(yu)被試(shi)品(pin)高(gao)壓端(duan)連接(jie)。
b.低壓側接(jie)線端(duan)子—與勵磁(ci)變輸出端(duan)連接(jie)。
c.多(duo)臺電抗器串(chuan)聯時上節(jie)的(de)低壓側與下節(jie)高壓側連接(jie)(jie)。諧振電抗器采用多(duo)臺串(chuan)聯或并(bing)聯的(de)連接(jie)(jie)方式。
8.額定(ding)容量下(xia)連續運行為規定(ding)工作時間下(xia),電(dian)抗器(qi)對空(kong)氣的溫升(sheng)不(bu)大(da)于60K;
9.性能及(ji)特點:電抗(kang)器(qi)設(she)計(ji)干式(shi)、環氧澆鑄(zhu),電抗(kang)器(qi)可以自由(you)方便疊裝。環氧樹脂絕(jue)緣筒外殼(ke),具有足夠的電氣、機械強(qiang)度,必要的散熱能力以及(ji)油熱脹冷縮(suo)的裕度。外殼(ke)上下蓋板,顏色為(wei)橘紅色。
十、電(dian)容分壓(ya)器技術參數:
額定(ding)電壓:200kV;
工作頻率:30~300Hz;
分壓比:2000:1;
分壓比誤差:1%;
電容分壓器接線端子如圖(tu)所示:
高(gao)壓端—與電抗(kang)器高(gao)壓側及被試品高(gao)壓側相連。
測(ce)量(liang)(liang)插座(zuo)—采用專配的測(ce)量(liang)(liang)電纜(lan)與控(kong)制箱背板測(ce)量(liang)(liang)輸入端連接。
接(jie)(jie)地端(duan)—采用專配接(jie)(jie)地線(xian)按接(jie)(jie)線(xian)圖指示接(jie)(jie)地。
4.性(xing)能(neng)及特點(dian):
a.額定電壓下可連續運行2小(xiao)時。
b.在30~300Hz范圍內,其(qi)精度和穩定度保(bao)持不變(bian)。
c.在20℃溫度下電容分壓器介質損耗值≤0.0025
d.電容分壓器(qi)配有支撐(cheng)底架(jia),具有足夠的穩定(ding)性。
e.電(dian)壓(ya)測(ce)(ce)量通(tong)過專(zhuan)用測(ce)(ce)試引線引至調頻電(dian)源進行測(ce)(ce)量。
試(shi)驗(yan)接線(xian)圖:
110kv主變、GIS試驗(yan)接線(xian)
35kv電(dian)纜(lan)試驗接線圖
10kv電纜試驗接(jie)線(xian)圖
十二、設備保存(cun)和(he)維護
1、存放于干燥(zao)、清(qing)潔場地(di),防止雨(yu)水、灰塵進入(ru)部(bu)件內部(bu);
2、如若長期不使(shi)用,正常天氣至少(shao)2個月應通(tong)(tong)(tong)電一(yi)(yi)次時(shi)間(jian)不少(shao)于半小時(shi),雨季及潮濕期應每(mei)隔一(yi)(yi)個月通(tong)(tong)(tong)電一(yi)(yi)次,通(tong)(tong)(tong)電時(shi)間(jian)半小時(shi),以驅除設備(bei)內的(de)潮氣防止電子元器(qi)件的(de)銹蝕(shi),影響正常使(shi)用。
3、定期(qi)檢查裝置各(ge)部件,確保各(ge)接頭緊固(gu)無松動;
4、更換打印紙,機器(qi)采(cai)用熱敏打印紙并(bing)且是前換紙式當需要(yao)(yao)換紙時(shi)只要(yao)(yao)按POST鍵(jian)鈕打印紙艙門(men)就會打開可以將新打印紙裝(zhuang)入;
十三、常見故障排除
故障現象
|
發 生 原 因
|
排 除 方 法(fa)
|
找(zhao)不到(dao)諧振點
|
接線有誤。
輸(shu)出開關未開,;
3、做(zuo)GIS時PT二次回路未(wei)打開;
4、試品Q值太低;
5、起始激勵功率太低;
6、試驗回路(lu)有短路(lu)現象;
7、找頻范圍(wei)不對。
|
退出(chu)試驗(yan)狀態(tai),合上輸出(chu)開(kai)(kai)關,檢查接線;打開(kai)(kai)PT二次回路(lu);
調高起(qi)始功率(∠30%);
用兆歐表測量試品絕緣(yuan)
重新設置找頻范圍(wei)
|
諧振后,電壓(ya)升不上去
|
1、試品Q值太(tai)低;
2、激勵電(dian)壓不夠;
3、電抗器底部(bu)有鐵磁物體;
4、3次諧(xie)波諧(xie)振。
|
檢查試品;
改變(bian)激勵(li)變(bian)壓(ya)器(qi)繞組接法,提高勵(li)磁電壓(ya)
絕緣筒架高電抗器或離開(kai)鐵磁(ci)物體(ti)。
|
主機自動復(fu)位
|
供電(dian)電(dian)源容(rong)量不夠;
電源引線過(guo)長或線徑過(guo)小(xiao);
接頭處接觸**;
供電(dian)電(dian)壓波動;
按鍵死接(jie)觸。
|
增加供電(dian)電(dian)源(yuan)容(rong)量(liang);
換(huan)較(jiao)粗導(dao)線,減小導(dao)線長(chang)度;
檢查接頭;
減小供電電壓(ya)波動(dong)。
|
開機后線路(lu)跳閘
|
線路漏電保護器較為敏(min)感(gan);
空氣開關容量不夠。
|
跨過漏電保護器或空氣開關的接(jie)線;
改換較大容量的空氣開關。
|
電壓(ya)跌落
|
試品放(fang)電或擊穿
|
檢查試品(pin)
|
輸出(chu)短路(lu)
|
電流超過本機限流值(zhi)。
|
檢查接線和試品。
|
試品電(dian)壓不準
|
分壓比設置錯誤或分壓器信(xin)號傳輸有問題。
|
重設分壓比(bi)或(huo)檢(jian)查分壓器接(jie)線。
|
電壓閃變
|
試驗電壓劇(ju)烈波動,變(bian)化率超過(guo)本機限(xian)定值(zhi)。
|
檢查供電(dian)(dian)電(dian)(dian)源電(dian)(dian)壓穩定性或試品(pin)參數的變(bian)化。
|
回(hui)路無電(dian)流
|
|
檢查接線和試品。
|
未接好地線
|
|
檢查(cha)接地線和(he)地樁,按說明(ming)書要求連接。
|
試品過電壓
|
手動(dong)升壓(ya)太快(kuai)或失控。
|
改變調(diao)壓步(bu)距或(huo)改用自動(dong)升壓 。
|
系統不諧(xie)振(zhen)
|
接(jie)線有誤或(huo)試品(pin)Q值太低。
|
檢查接(jie)線和試品
|
十四、常用設備(bei)資料參考
交聯聚(ju)乙烯電(dian)纜(lan)單(dan)位長度電(dian)容量
電纜導(dao)體截面積(平方毫(hao)米)
|
電 容 (μ/km)
|
YJV、YJLV
|
YJV、YJLV
|
YJV、YJV、YJLV
|
YJV、YJLV
|
YJV、YJLV
|
6/6kV、6/10kV
|
8.7/10kV、8.7/15kV
|
12/35kV
|
21/35kV
|
26/35kV
|
1×35
|
0.212
|
0.173
|
0.152
|
|
|
1×50
|
0.237
|
0.192
|
0.166
|
0.118
|
0.114
|
1×70
|
0.270
|
0.217
|
0.187
|
0.131
|
0.125
|
1×95
|
0.301
|
0.240
|
0.206
|
0.143
|
0.135
|
1×120
|
0.327
|
0.261
|
0.223
|
0.153
|
0.143
|
1×150
|
0.358
|
0.284
|
0.241
|
0.164
|
0.153
|
1×185
|
0.388
|
0.307
|
0.267
|
0.180
|
0.163
|
1×240
|
0.430
|
0.339
|
0.291
|
0.194
|
0.176
|
1×300
|
0.472
|
0.370
|
0.319
|
0.211
|
0.190
|
1×400
|
0.531
|
0.418
|
0.352
|
0.231
|
0.209
|
1×500
|
0.603
|
0.438
|
0.388
|
0.254
|
0.232
|
1×600
|
0.667
|
0.470
|
0.416
|
0.287
|
0.256
|
2、交聯(lian)聚(ju)乙烯(xi)電(dian)纜單位長度電(dian)容量
電(dian)纜導體截面積(平(ping)方毫(hao)米)
|
電 容 (μF/km)
|
YJV、YJLV
|
YJV、YJLV
|
YJV、YJV、YJLV
|
YJV、YJLV
|
YJV、YJLV
|
6/6kV、6/10kV
|
8.7/10kV、8.7/15kV
|
12/35kV
|
21/35kV
|
26/35kV
|
3×35
|
0.212
|
0.173
|
0.152
|
|
|
3×50
|
0.237
|
0.192
|
0.166
|
0.118
|
0.114
|
3×70
|
0.270
|
0.217
|
0.187
|
0.131
|
0.125
|
3×95
|
0.301
|
0.240
|
0.206
|
0.143
|
0.135
|
3×120
|
0.327
|
0.261
|
0.223
|
0.153
|
0.143
|
3×150
|
0.358
|
0.284
|
0.241
|
0.164
|
0.153
|
3×185
|
0.388
|
0.307
|
0.267
|
0.180
|
0.163
|
3×240
|
0.430
|
0.339
|
0.291
|
0.194
|
0.176
|
3×300
|
0.472
|
0.370
|
0.319
|
0.211
|
0.190
|
3×400
|
0.531
|
0.418
|
0.352
|
0.231
|
0.209
|
3×500
|
0.603
|
0.438
|
0.388
|
0.254
|
0.232
|
3×600
|
0.667
|
0.470
|
0.416
|
0.287
|
0.256
|
3、交聯聚乙烯(xi)電(dian)纜單位長度電(dian)容量(liang)
電纜導(dao)體截(jie)面積(平方(fang)毫米)
|
電 容 (μF/km)
|
YJV、YJLV
|
YJV、YJLV
|
64/110kV
|
128/220kV
|
3×240
|
0.129
|
|
3×300
|
0.139
|
|
3×400
|
0.156
|
0.118
|
3×500
|
0.169
|
0.124
|
3×630
|
0.188
|
0.138
|
3×800
|
0.214
|
0.155
|
3×1000
|
0.231
|
0.172
|
3×1200
|
0.242
|
0.179
|
3×1400
|
0.259
|
0.190
|
3×1600
|
0.273
|
0.198
|
3×1800
|
0.284
|
0.297
|
3×2000
|
0.296
|
0.215
|
3×2200
|
|
0.221
|
3×2500
|
|
0.232
|
4、60kV級全絕緣變壓器的電(dian)容(rong)(pF)
類 型
|
變 壓 器 容(rong) 量 kVA
|
630
|
2000
|
3150
|
6300
|
8000
|
1600
|
高(gao)壓(ya)-地
|
2700
|
4100
|
4600
|
5900
|
7000
|
8200
|
低壓(ya)-地
|
4200
|
6600
|
7900
|
10000
|
11000
|
15300
|
對于表中沒有的產品(pin),可(ke)根據(ju)表中的上、下容量近似(si)地(di)估(gu)算。同容量的雙繞(rao)組變壓器,其繞(rao)組電(dian)容要比三繞(rao)組產品(pin)小。
5、110kV級中性點分級絕緣變壓(ya)器的電容(pF)
類 型(xing)
|
變 壓 器 容 量kVA
|
50000
|
31500
|
20000
|
10000
|
5600
|
高壓-中壓、低壓、地(di)
|
14200
|
11400
|
8700
|
6150
|
4200
|
中壓-高壓、低壓、地
|
24800
|
11800
|
13200
|
9600
|
-
|
低(di)壓(ya)-高壓(ya)、中壓(ya)、地
|
19300
|
19300
|
12000
|
9400
|
6800
|
6、220kV級(ji)(ji)中(zhong)性點(dian)非全級(ji)(ji)絕(jue)緣部分變壓器的(de)電容(rong)(pF)
試 品(pin) 型 號
|
SEPSL-63000
|
SSPSL-120000
|
SSPSL-240000
|
類 型
|
高(gao)壓(ya)-中壓(ya)、低壓(ya)及地
|
12100
|
13500
|
17050
|
中(zhong)壓-高壓、低壓及地
|
18500
|
19700
|
23260
|
低壓(ya)-高壓(ya)、中壓(ya)及地
|
18200
|
23600
|
29940
|
試(shi) 品 型 號
|
SFPL-240000
|
SFP-360000
|
SFPSZL-120000
|
類 型
|
高(gao)壓-中(zhong)壓、低(di)壓及地
|
32230
|
33910
|
38020
|
中壓(ya)(ya)(ya)-高壓(ya)(ya)(ya)、低壓(ya)(ya)(ya)及(ji)地
|
-
|
-
|
23260
|
低壓-高壓、中壓及(ji)地
|
22470
|
23790
|
22160
|
7、油浸式電力變壓(ya)(ya)器交(jiao)流試驗電壓(ya)(ya)
額定(ding)電壓
(k V)
|
*高工作
電壓(ya)(k V)
|
線端交流試驗電壓值(kV)
|
中性點交(jiao)流(liu)試驗電壓值(kV)
|
全部更換(huan)繞組
|
部分更換繞(rao)組或交接
|
全(quan)部(bu)更換繞組(zu)
|
部分更(geng)換(huan)繞組(zu)或(huo)交接
|
<1
|
≤1
|
3
|
2.5
|
3
|
2.5
|
3
|
3.5
|
18
|
15
|
18
|
15
|
6
|
6.9
|
25
|
21
|
25
|
21
|
10
|
11.5
|
35
|
30
|
35
|
30
|
15
|
17.5
|
45
|
38
|
45
|
38
|
20
|
23.0
|
55
|
47
|
55
|
47
|
35
|
40.5
|
85
|
72
|
85
|
72
|
110
|
126.0
|
200
|
170(195)
|
95
|
80
|
220
|
252.0
|
360
|
306
|
85
|
72
|
395
|
336
|
(200)
|
(170)
|
500
|
550.0
|
630
|
536
|
85
|
72
|
680
|
578
|
140
|
120
|
8、部分型號發電(dian)機定子繞(rao)組(zu)的單相(xiang)對地電(dian)容量
類別
|
發 電 機
|
型號
|
生(sheng)產廠家
|
額定(ding)容量(MW)
|
額(e)定電(dian)壓(kV)
|
相電容(mF)
|
火
力
發
電
機(ji)
|
QFS-125-2
|
上海電機廠
|
125
|
13.8
|
0.08-0.12
|
QFSN-200-2
|
哈爾濱電(dian)機廠(chang)
|
200
|
15.75
|
0.19-0.21
|
QFQS-200-2
|
東方(fang)電機廠
|
200
|
15.75
|
0.1928-0.21
|
QFQS-200-2
|
北京重型電機廠
|
200
|
15.75
|
0.18-0.19
|
QFS-300-2
|
上海電(dian)機廠
|
300
|
18.0
|
0.16-0.20
|
QFSN-300-2
|
上海電(dian)機(ji)廠(chang)
|
300
|
18.0
|
0.18-0.20
|
ATB-2
|
美國(guo)GE公司
|
352
|
23.0
|
0.268(設計值)
|
TBB-320-2
|
(前蘇(su)聯)
|
320
|
20.0
|
0.31
|
2-105×234
|
美國西屋公司
|
600
|
20.0
|
0.2(工(gong)廠(chang)試驗值)
|
50WT23E-138
|
ABB
|
600
|
22.0
|
0.253(設計值(zhi))
|
水 發
力 電
機
|
|
|
72.5 - 85
|
10.5
|
0.694
|
|
|
300
|
15.75
|
1.7-2.5
|
|
|
400
|
18.0
|
2-2.5
|
9、同步發(fa)電(dian)機(ji)定(ding)子(zi)繞組交流(liu)試(shi)驗電(dian)壓
1
|
全部更換定(ding)子繞組并(bing)修(xiu)好后的試(shi)驗(yan)電壓
|
容(rong)量kW或kVA
|
小于10000
|
10000及(ji)以上
|
額(e)定電(dian)壓Un (V)
|
36以上(shang)
|
6000以(yi)下(xia)
|
6000~18000
|
18000以上(shang)
|
試驗電壓(ya)V
|
2Un+1000但*低為(wei)1500
|
2.5Un
|
2Un
+3000
|
按(an)專門協議(yi)
|
2
|
大修(xiu)前(qian)或局部更(geng)換定子繞組并修(xiu)好(hao)后(hou)的試(shi)驗電壓
|
運(yun)行20年及以(yi)下(xia)者
|
1.5 Un
|
運行(xing)20年以上(shang)與架空(kong)線路直接(jie)連接(jie)者
|
1.5 Un
|
運行20年(nian)以上不與架空線路直接連(lian)接者
|
(1.3~1.5)Un
|
十五、設備成(cheng)套性:
變頻(pin)電源 1臺
勵磁變(bian)壓器 1臺(tai)
電抗器 4臺
電(dian)容分壓器 1臺(tai)
附(fu)件及(ji)測試線 1套
支(zhi)架 15KV 1只(zhi)
均壓罩 200KV 2只
絕緣(yuan)底板 2塊
一、產品概(gai)述
YDQC系(xi)列輕型(xing)交直流(liu)高(gao)壓(ya)試(shi)驗(yan)變(bian)壓(ya)器(qi)是(shi)在(zai)同類(lei)產(chan)(chan)品YDJ(G)型(xing)高(gao)壓(ya)試(shi)驗(yan)變(bian)壓(ya)器(qi)的基礎上,按試(shi)驗(yan)變(bian)壓(ya)器(qi)國家標(biao)準ZBK41006—89要(yao)求(qiu),經改進后(hou)生產(chan)(chan)的一(yi)種(zhong)新型(xing)產(chan)(chan)品,本系(xi)列產(chan)(chan)品具(ju)有體積小、重量輕、結構緊(jin)湊、功能(neng)齊全、使用方便等特點。實用于電力、工(gong)礦(kuang)、科研等部門,對各種(zhong)高(gao)壓(ya)電氣設(she)備、電氣元件、絕緣材料(liao)進行(xing)工(gong)頻耐壓(ya)試(shi)驗(yan)和(he)直流(liu)泄漏試(shi)驗(yan),是(shi)高(gao)壓(ya)試(shi)驗(yan)中(zhong)必(bi)不(bu)可少(shao)的儀(yi)器(qi)。
二、產(chan)品結構
YDQC系列輕(qing)型高(gao)壓試驗變(bian)壓器鐵(tie)芯(xin)為(wei)單框(kuang)式。線圈采用同(tong)芯(xin)圓筒多層塔式結(jie)構,初級低壓繞(rao)(rao)組(zu)(zu)繞(rao)(rao)在(zai)(zai)鐵(tie)芯(xin)上,次級高(gao)壓繞(rao)(rao)組(zu)(zu)繞(rao)(rao)在(zai)(zai)低壓繞(rao)(rao)組(zu)(zu)外(wai)側,這種同(tong)軸布(bu)置減(jian)少了繞(rao)(rao)組(zu)(zu)間(jian)的藕合損耗(hao)。高(gao)壓硅堆用特殊工藝封裝在(zai)(zai)套管內(nei),產(chan)品的外(wai)殼制成與器芯(xin)配(pei)合較佳的八角(jiao)形(xing)結(jie)構,整體外(wai)型美觀大(da)方(fang)。其內(nei)外(wai)部結(jie)構見圖1。
1-均壓(ya)(ya)(ya)(ya)(ya)球;2-硅(gui)堆(dui)短路桿(gan);3-高(gao)(gao)壓(ya)(ya)(ya)(ya)(ya)套(tao)管;4-油(you)閥;5-殼體;6、7-調(diao)整電壓(ya)(ya)(ya)(ya)(ya)輸入a、x端子;8、9-儀(yi)表(biao)測(ce)量E、F端子;10-高(gao)(gao)壓(ya)(ya)(ya)(ya)(ya)尾X端子;11-變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)外殼接(jie)地端;12-高(gao)(gao)壓(ya)(ya)(ya)(ya)(ya)輸出A端子;13-高(gao)(gao)壓(ya)(ya)(ya)(ya)(ya)整流(liu)硅(gui)堆(dui);14-內部均壓(ya)(ya)(ya)(ya)(ya)環;15-變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)鐵芯;16-初級(ji)低(di)壓(ya)(ya)(ya)(ya)(ya)繞(rao)組;17-測(ce)量儀(yi)表(biao)繞(rao)組;18-二次級(ji)高(gao)(gao)壓(ya)(ya)(ya)(ya)(ya)繞(rao)組;19-變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)油(you)。
三、工作原理
YDQC系列輕型高壓(ya)試驗(yan)變(bian)(bian)壓(ya)器為單相變(bian)(bian)壓(ya)器,聯結組(zu)標號II。單臺高壓(ya)試驗(yan)變(bian)(bian)壓(ya)器的工作過程(cheng),用交流(liu)220V(10KVA以上(shang)為380V)電壓(ya)接入電源控制(zhi)箱(xiang)(臺),經電源控制(zhi)箱(xiang)(臺)內自藕調壓(ya)器(50KVA以上(shang)調壓(ya)器外附)調節(jie)0~200V(10KVA以上(shang)0~400V)電壓(ya)至試驗(yan)變(bian)(bian)壓(ya)器的初級(ji)繞(rao)組(zu),根(gen)據電磁感應原(yuan)理,在試驗(yan)變(bian)(bian)壓(ya)器高壓(ya)繞(rao)組(zu)可獲得試驗(yan)所需的高電壓(ya)。其工作原(yuan)理圖(tu)見圖(tu)2所示。
1、單(dan)臺YDQC高壓試驗變壓器工作(zuo)原理示意(yi)圖(tu)
在試驗變壓器中(zhong):a、x為(wei)低(di)壓輸(shu)入端;A、X 為(wei)高(gao)壓輸(shu)出端;E、F為(wei)儀表測量端。
2、單臺交直流兩用型高壓試驗變壓器工作原理見圖3。圖中所示:高壓套管內裝有高壓硅堆,串接在高壓回路中作高壓整流,以獲得直流高電壓。當用一短路桿將高壓硅堆短接時,可獲得交流高電壓,其狀態為交流輸出;反之在抽出短路桿時,其狀態為直流輸出。
3、三臺高壓試驗變壓器串激獲得更高電壓原理見圖4,串激高壓試驗變壓器有很大的優越性,因為整個試驗裝置由多個單臺串激式試驗變壓器組成,單臺試驗變壓器有著體積小、重量輕、便于運輸的特點,它既可以串接成高出幾倍的單臺試驗變壓器輸出電壓組合使用,又可以分開單獨使用。整套試驗裝置投資小、經濟實惠。圖3所示:在三臺串激式試驗變壓器串激使用中,單臺試驗變壓器B1、B2、B3的輸出電壓都是U,**、二級的試驗變壓器內部都有一個激磁繞組,分別為A1、C1 和A2、C2。當控制電壓加在第**試驗變壓器B1的初級繞組a1、x1上,激磁繞組A1、C1給予試驗變壓器B2初級繞組供電,**級試驗變壓器B2的激磁繞組A2、C2給試驗變壓器B3的初級繞組供電。由于第**試驗變壓器B1的高壓尾及殼體接地,**、三級的試驗變壓器B2和B3對地有絕緣支架的隔離,這樣試驗變壓器B1、B2、B3對地輸出電壓分別為1U、2U、3U。
B1、B2、B3- 串激式高壓變壓器;1U、2U、3U-各級對地電壓;
PV- 高壓示值表(KV); ZJ1、ZJ2-絕緣支架(jia)。
四(si)、使用方法及注意事(shi)項(xiang)
1、YDQC高(gao)壓(ya)(ya)(ya)試(shi)驗(yan)變(bian)壓(ya)(ya)(ya)器(qi)做工(gong)頻(pin)耐壓(ya)(ya)(ya)試(shi)驗(yan)使用(yong)接線方法見圖5。做工(gong)頻(pin)耐壓(ya)(ya)(ya)試(shi)驗(yan)前,先根據試(shi)驗(yan)變(bian)壓(ya)(ya)(ya)器(qi)的額定容(rong)量(liang)選(xuan)擇好限流電(dian)阻,(水電(dian)阻)的阻值(zhi),再根據被試(shi)品需加(jia)(jia)的高(gao)壓(ya)(ya)(ya)電(dian)壓(ya)(ya)(ya)值(zhi)調整(zheng)好放(fang)電(dian)球(qiu)隙的球(qiu)間距,為了提高(gao)對被試(shi)品施加(jia)(jia)電(dian)壓(ya)(ya)(ya)的測(ce)(ce)量(liang)精度,應在高(gao)壓(ya)(ya)(ya)側接入(ru)FRC阻容(rong)分壓(ya)(ya)(ya)器(qi)來(lai)測(ce)(ce)量(liang)電(dian)壓(ya)(ya)(ya)。
R1、R2- 限流電阻; Qx- 放電球隙; Zx- 被試品(pin);
FRC- 阻容分壓器; V- 分壓器高壓表。
按照圖4、結合圖2所進行的工頻耐壓試驗接好工作線路,試驗變壓器的高壓繞阻的X端(高壓尾)、儀表測量繞組的F端、試驗變壓器的外殼以及電源控制箱(臺)的外殼必須可靠接地。
用三臺試驗變壓器串激做工頻耐壓試驗時、**、三級試驗變壓器的初級繞組X端,儀表測量繞組的F端,以及高壓繞組的X端(高壓尾)均接本級試驗變壓器的外殼,**、三級試驗變壓器的主體必須放置在絕緣支架上。除第**以外、**、三級試驗變壓器的主體不要接地線。其接線方式見圖3所示。
接電源前,電源控制箱(臺)的調壓器必須調到零位。接通電源后,綠色指示燈亮,按一下啟動按鈕,紅色指示燈亮,表示試驗變壓器已接通控制電源,開始升壓。
從零位開始按順時針方向勻速旋轉調壓器手輪升壓。(升壓方式有:快速升壓法,即20S逐級升壓法,慢速升壓法,即60S逐級升壓法,極慢速升壓法供選用)電壓從零開始按選定的升壓速度升到您所需額定試驗電壓的75%后,再以每秒2%額定試驗電壓的速度升到您所需試驗電壓,并密切注意測量儀表的指示以及被試品的情況,被試品施加電壓的時間到后。應在數秒內勻速將調壓器返回,高壓降至1/3試驗電壓以下,按一下停止按鈕,高壓、低壓輸出停止,然后切斷電源線,試驗完畢。
工頻耐壓試驗操作過程注意事項
1、試驗人員應做好責任分工,設定好試驗現場的**距離,仔細檢查好被試品及試驗變壓器的接地情況,并設有專人監護**及觀察被試品狀態工作。
2、被試品主要部位應**干凈,保持**干燥,以免損壞被試品和帶來試驗數值的誤差。
3、對大型設備的試驗,一般都應先進行試驗變壓器的空升試驗,即不接試品時升壓至試驗電壓,以便校對好儀表的指示精度,調整好放電球隙的球間距。
4、做耐壓試驗時升壓速度不能過快,并防止突然加壓,例如調壓器不在零位的突然合閘,也不能突然斷電,一般應在調壓器降至零位時分閘。
5、在升壓或耐壓試驗過程中,如發現下列不正常情況,1 電壓、電流表指針擺動很大,2 被試品發出不正常響聲,3 發現絕緣有燒焦或冒煙現象,應立即降壓,切斷電源,停止試驗并查明原因。
6、使用本產品做高壓試驗時,除熟悉本說明書外,還必須嚴格執行國家有關標準和操作規程。
2、YDQ交(jiao)直(zhi)(zhi)(zhi)流(liu)(liu)兩用(yong)高壓(ya)(ya)(ya)(ya)試(shi)驗(yan)(yan)變壓(ya)(ya)(ya)(ya)器做(zuo)(zuo)直(zhi)(zhi)(zhi)流(liu)(liu)耐壓(ya)(ya)(ya)(ya)和(he)泄漏(lou)試(shi)驗(yan)(yan)使用(yong)接(jie)線方法(fa)見圖(tu)5。由(you)于是(shi)交(jiao)直(zhi)(zhi)(zhi)流(liu)(liu)兩用(yong)高壓(ya)(ya)(ya)(ya)試(shi)驗(yan)(yan)變壓(ya)(ya)(ya)(ya)器,應(ying)把高壓(ya)(ya)(ya)(ya)硅堆短路(lu)(lu)桿從套管中抽出(chu)(chu)(chu),使試(shi)驗(yan)(yan)變壓(ya)(ya)(ya)(ya)器為直(zhi)(zhi)(zhi)流(liu)(liu)輸出(chu)(chu)(chu)狀態。做(zuo)(zuo)直(zhi)(zhi)(zhi)流(liu)(liu)泄漏(lou)試(shi)驗(yan)(yan)前,先根(gen)據泄漏(lou)試(shi)驗(yan)(yan)中輸出(chu)(chu)(chu)端斷路(lu)(lu)電(dian)流(liu)(liu)不(bu)超過高壓(ya)(ya)(ya)(ya)硅堆的(de)*大整流(liu)(liu)為宜,選(xuan)擇好(hao)限流(liu)(liu)電(dian)阻(zu)(水電(dian)阻(zu))的(de)阻(zu)值(zhi),再根(gen)據被試(shi)品(pin)對直(zhi)(zhi)(zhi)流(liu)(liu)高壓(ya)(ya)(ya)(ya)波(bo)形的(de)要求選(xuan)擇好(hao)高壓(ya)(ya)(ya)(ya)濾(lv)波(bo)電(dian)容(rong)的(de)電(dian)容(rong)值(zhi)。為了提高對被試(shi)品(pin)施加電(dian)壓(ya)(ya)(ya)(ya)的(de)測(ce)量精(jing)度,應(ying)在高壓(ya)(ya)(ya)(ya)側接(jie)入FRC阻(zu)容(rong)分壓(ya)(ya)(ya)(ya)器來測(ce)量電(dian)壓(ya)(ya)(ya)(ya)。
R- 限流電(dian)阻; C- 高壓濾波(bo)電(dian)容; Zx- 被試品; G- 硅堆(dui)短路(lu)桿;
FRC- 阻容分壓器;V- 分壓器高壓表;uA- 微安表;D- 高壓整流硅堆。
按照圖5、結合圖3所進行的直流泄漏試驗接好工作線路。試驗變壓器的高壓繞組的X端(高壓尾)、儀表測量繞組的F 端、試驗變壓器的外殼以及電源控制箱(臺)的外殼必須可靠接地。
接電源(yuan)前、電源(yuan)控制箱(臺(tai))的(de)調壓(ya)器(qi)(qi)必(bi)須調到零位。接通電源(yuan)后,綠色指示燈(deng)(deng)亮(liang),按(an)一(yi)下(xia)啟動(dong)按(an)鈕,紅(hong)色指示燈(deng)(deng)亮(liang),表示試驗變壓(ya)器(qi)(qi)已接通控制電源(yuan),開始升壓(ya)。
從(cong)零(ling)位開始按(an)(an)(an)順(shun)時針方向勻速(su)(su)旋(xuan)轉調壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器手輪升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)。(升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)方式有(you):快(kuai)速(su)(su)升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)法即(ji)20S逐(zhu)(zhu)級(ji)升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)法;慢速(su)(su)升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)法,即(ji)60S逐(zhu)(zhu)級(ji)升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)法;級(ji)慢速(su)(su)升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)法供選(xuan)用)電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)從(cong)零(ling)開始按(an)(an)(an)選(xuan)定的升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)速(su)(su)度升(sheng)(sheng)(sheng)到您所需(xu)額定試(shi)驗(yan)電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)或(huo)額定直(zhi)流(liu)(liu)電(dian)(dian)(dian)(dian)流(liu)(liu)下(xia)的參考電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)。試(shi)驗(yan)中應(ying)(ying)嚴密注意直(zhi)流(liu)(liu)高(gao)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)表(biao)、泄漏電(dian)(dian)(dian)(dian)流(liu)(liu)表(biao)指示以及(ji)被試(shi)品(pin)的情況。試(shi)驗(yan)完(wan)畢后,應(ying)(ying)訊速(su)(su)均勻將高(gao)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)降(jiang)至零(ling)位,按(an)(an)(an)一下(xia)停(ting)止(zhi)按(an)(an)(an)鈕,高(gao)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)、低壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)輸出停(ting)止(zhi),然后切斷(duan)電(dian)(dian)(dian)(dian)源。此時應(ying)(ying)用直(zhi)流(liu)(liu)高(gao)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)放**給被試(shi)品(pin)及(ji)試(shi)驗(yan)裝置(zhi)本(ben)身(shen)充分放電(dian)(dian)(dian)(dian)。
直流泄(xie)漏試驗(yan)操作過程(cheng)注(zhu)意事項
(1)試驗人員應做好責任分工,設定好試驗現場的**距離,仔細檢查好被試品及試驗變壓器的接地情況,并設有專人監護**及觀察被試品狀態工作。
(2)被試品做試驗前,應拆除所有對外連線,并充分放電,主要部位應**干凈,保持**干燥,以免損壞被試品及帶來試驗數值的誤差。
(3)對于大容量試品(電容器、超長電纜等)試驗時應緩慢升壓,防止被試品的充電電流過大而燒壞微安表,必要時應分級加壓分別讀取各電壓下微安表的穩定讀數。
(4)試驗過程中,應嚴密監視被試品、微安表及試驗裝置等,一旦發生閃爍、擊穿等現象應立即降壓,切斷電源,并查明原因。
五(wu)、配套選(xuan)購產品
下列產品僅供選擇,購買時需另行計價。
1.KZX系列電源控制箱 容量:1KVA-5KVA、輸入電壓:220V
2.KZT系列電源控制臺 容量:10KVA~300KVA輸入電壓:220V或380V
3.數字微安表:SWB-II
4.高壓濾波電容: 0.01MF、40 ~ 100KV
5.高壓直流放**: FBR— 70、140、210KV
6.放電球隙: Q—50、100、150、200、250、500
7.標準試油杯: 400ml
8.折疊式手推車: 150、300型
9.絕緣支架: 50、100、200、300、400KV
10.阻容分壓器: FRC —50、100、150、200KV
11.高壓硅堆: 2DL—150、300、450KV
12.水 電 阻: 50、100
六、主要試驗設備的選(xuan)擇
1、試驗變壓器
其高壓側額定電壓應不小于被試品的*高試驗電壓,額定電流不小于被試品的*大電容電流。被試品的電容電流和試驗變壓器所需容量計算式為:
被試品電(dian)容量Cx可由交流電(dian)橋測出。常用(yong)的被試品電(dian)容量按(an)表1選取。
幾(ji)種常用被試品的(de)電容(rong)量(pF) 表1
2、調(diao)壓設備
(1)自藕調壓器。其調壓范圍廣、功率損耗小、波形畸變小、選擇這種調壓方式為*好。自藕調壓器的容量按0.75 ~ 1倍的試驗變壓器的容量選擇,適用于容量為100KVA以下的試驗變壓器的調壓。
(2)感應調壓器。其調壓范圍大,波形畸形小、但結構復雜、價格較貴,當試驗變壓器的容量較大時(如100KVA以上)使用。
3、限流電阻
限流電阻的作用是,當被試品擊穿時,限制斷路電流,從而保護試驗變壓器,防止故障的擴大。其數值以*高試驗電壓為準,按0.5 ~ 1 Ω / V(有效值)選擇,限流電阻可用水電阻。注意水不能充滿玻璃管,應留有余地,以防爆裂。
4、放電球隙
放電球隙的布置方式有垂直和水平兩種,球隙間距S和球的直徑D的關系應保護在0.05D ≤S ≤0.5D范圍內,球隙上的水電阻阻值一般按0.1 ~ 1Ω/V選取,設置放電球隙的目的是為了對重要的被試品起保護作用,可以將由于誤操作或被試品擊穿引起的過電壓限制在允許的范圍內。
七、試(shi)驗變壓器技術指示
型號
|
容量(liang)
|
高壓(ya)電(dian)壓(ya)
|
高(gao)壓電流
|
低壓(ya)輸入
|
變比
|
溫升℃
|
(KVA)
|
(KV)
|
(mA)
|
電(dian)壓(V)
|
電流(A)
|
高/儀
|
30分鐘
|
YDQC-1.5/50
|
1.5
|
50
|
30
|
200
|
7.5
|
500
|
10
|
YDQC-3/50
|
3
|
50
|
60
|
200
|
15
|
500
|
10
|
YDQC-5/50
|
5
|
50
|
100
|
200
|
25
|
500
|
10
|
YDQC-10/50
|
10
|
50
|
200
|
200
|
50
|
500
|
10
|
YDQC-15/50
|
15
|
50
|
300
|
200
|
75
|
500
|
10
|
YDQC-20/50
|
20
|
50
|
400
|
380
|
53
|
500
|
10
|
YDQC-30/50
|
30
|
50
|
600
|
380
|
79
|
500
|
10
|
YDQC-50/50
|
50
|
50
|
1000
|
380
|
12
|
500
|
10
|
YDQC-5/100
|
5
|
100
|
50
|
200
|
25
|
1000
|
10
|
YDQC-10/100
|
10
|
100
|
100
|
200
|
50
|
1000
|
10
|
YDQC-20/100
|
20
|
100
|
200
|
400
|
50
|
1000
|
10
|
YDQC-30/100
|
30
|
100
|
300
|
400
|
75
|
1000
|
10
|
YDQC-50/100
|
50
|
100
|
500
|
400
|
125
|
1000
|
10
|
YDQC-20/150
|
20
|
150
|
133
|
400
|
50
|
1500
|
10
|
YDQC-30/150
|
30
|
150
|
200
|
400
|
75
|
1500
|
10
|
YDQC-50/150
|
50
|
150
|
333
|
400
|
125
|
1500
|
10
|
YDQC-100/150
|
100
|
150
|
667
|
400
|
250
|
1500
|
10
|
YDQC-50/200
|
50
|
200
|
250
|
400
|
125
|
2000
|
10
|
YDQC-100/200
|
100
|
200
|
500
|
400
|
250
|
2000
|
10
|
YDQC-150/200
|
150
|
200
|
750
|
400
|
375
|
2000
|
10
|
YDQC-200/200
|
200
|
200
|
1000
|
400
|
500
|
2000
|
10
|
YDQC-300/200
|
300
|
200
|
1500
|
400
|
600
|
2000
|
10
|
YDQC-50/300
|
50
|
300
|
170
|
400
|
125
|
3000
|
10
|
YDQC-100/300
|
100
|
300
|
333
|
400
|
250
|
3000
|
10
|
YDQC-150/300
|
150
|
300
|
500
|
400
|
375
|
3000
|
10
|
YDQC-200/300
|
200
|
300
|
667
|
400
|
500
|
3000
|
10
|
YDQC-300/300
|
300
|
300
|
3000
|
500
|
600
|
3000
|
10
|
1、使用環境條件
環境溫度不高于+40℃、不低于—20℃;空氣相對濕度不大于90%;海拔高度不超過2000米;
2、工作電壓
電源控制箱(臺)輸入電壓為工頻220V或380V、相對誤差不超過±10%;(具體使用電壓根據用戶所定試驗變壓器規格選取)
八、隨貨文件
YDQC 系列試驗變壓器產品說明書 1份
產品出廠試驗報告 1份
產品合格證 1份
裝箱單 1份
一(yi)、概述
YDQ系列高(gao)(gao)壓(ya)(ya)(ya)(ya)(ya)試(shi)驗(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)是(shi)根據《試(shi)驗(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)》標(biao)準,在油浸式試(shi)驗(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)的(de)(de)(de)(de)(de)基礎(chu)上而設計(ji)生產(chan)的(de)(de)(de)(de)(de)。SF6氣(qi)(qi)體具(ju)有(you)良好的(de)(de)(de)(de)(de)電(dian)氣(qi)(qi)絕(jue)緣(yuan)性能及優(you)異的(de)(de)(de)(de)(de)滅(mie)弧(hu)性能,其耐壓(ya)(ya)(ya)(ya)(ya)強度(du)為同一壓(ya)(ya)(ya)(ya)(ya)力下(xia)氮氣(qi)(qi)的(de)(de)(de)(de)(de)2.5倍(bei)(bei),擊(ji)穿電(dian)壓(ya)(ya)(ya)(ya)(ya)的(de)(de)(de)(de)(de)空氣(qi)(qi)的(de)(de)(de)(de)(de)2.5倍(bei)(bei)。在0.25MPa下(xia)與油的(de)(de)(de)(de)(de)擊(ji)穿電(dian)壓(ya)(ya)(ya)(ya)(ya)相等(deng),在0.45MPa壓(ya)(ya)(ya)(ya)(ya)力下(xia)是(shi)油的(de)(de)(de)(de)(de)擊(ji)穿電(dian)壓(ya)(ya)(ya)(ya)(ya)的(de)(de)(de)(de)(de)2倍(bei)(bei),是(shi)一種優(you)于油的(de)(de)(de)(de)(de)新一代(dai)超高(gao)(gao)壓(ya)(ya)(ya)(ya)(ya)絕(jue)緣(yuan)介(jie)質材料。該產(chan)品(pin)(pin)(pin)技術要求完全符合《ZBK-41006-89》標(biao)準,它(ta)是(shi)油浸式輕型試(shi)驗(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)的(de)(de)(de)(de)(de)換代(dai)產(chan)品(pin)(pin)(pin)。該產(chan)品(pin)(pin)(pin)具(ju)有(you)體積小、重量輕、不受氣(qi)(qi)候變(bian)化(hua)影響、電(dian)暈小、現(xian)場(chang)搬運無需(xu)靜止可使(shi)用,使(shi)用壽(shou)命長、免(mian)維修等(deng)特點。適用于電(dian)力系統、工(gong)(gong)礦企業、科研部門等(deng)對各種高(gao)(gao)壓(ya)(ya)(ya)(ya)(ya)電(dian)氣(qi)(qi)設備、電(dian)氣(qi)(qi)元件、絕(jue)緣(yuan)材料進行工(gong)(gong)頻或直流(liu)高(gao)(gao)壓(ya)(ya)(ya)(ya)(ya)下(xia)的(de)(de)(de)(de)(de)絕(jue)緣(yuan)強度(du)試(shi)驗(yan)。
二、產品結構(gou)
YDQ系列高壓試驗(yan)變壓器采用單框(kuang)芯(xin)式(shi)鐵(tie)芯(xin)結(jie)構,初級繞(rao)(rao)組繞(rao)(rao)在鐵(tie)芯(xin)上,高壓繞(rao)(rao)組在外,這種同軸布(bu)置減少了(le)漏磁通,因而增大了(le)繞(rao)(rao)組間的耦(ou)合(he)。產品的外殼為(wei)圓柱(zhu)灌式(shi)容器結(jie)構,能耐受0.8MPa以上壓力。其(qi)結(jie)構見圖(tu)1:
三、工作原(yuan)理(li)
YDQ系列(lie)(lie)高(gao)壓(ya)(ya)(ya)試(shi)(shi)驗變壓(ya)(ya)(ya)器(qi)為(wei)單(dan)相變壓(ya)(ya)(ya)器(qi),聯結(jie)組(zu)標號Ⅰ.Ⅰ. 用(yong)(yong)工頻220V(10kVA以上(shang)為(wei)380V)電源接入 (為(wei)本公司生產的(de)(de)試(shi)(shi)驗變壓(ya)(ya)(ya)器(qi)配套專用(yong)(yong)設備,詳細資料請(qing)見(jian)其具體使用(yong)(yong)說明(ming)書(shu))系列(lie)(lie)操作(zuo)箱(xiang)(臺),經(jing)操作(zuo)箱(xiang)內(nei)自偶調(diao)壓(ya)(ya)(ya)器(qi)(50kVA以上(shang)調(diao)壓(ya)(ya)(ya)器(qi)外附)調(diao)節至0~200V(或(huo)0~400V)電壓(ya)(ya)(ya)輸出至YDQ試(shi)(shi)驗變壓(ya)(ya)(ya)器(qi)的(de)(de)初(chu)級(ji)繞組(zu),根據電磁感應原理,在試(shi)(shi)驗變壓(ya)(ya)(ya)器(qi)高(gao)壓(ya)(ya)(ya)繞組(zu)可獲得(de)試(shi)(shi)驗所需的(de)(de)高(gao)電壓(ya)(ya)(ya)。
單臺YDQ系列交直(zhi)流高(gao)(gao)(gao)壓(ya)試驗變壓(ya)器的(de)工(gong)作(zuo)原理圖見圖3,圖中(zhong)高(gao)(gao)(gao)壓(ya)套管(guan)中(zhong)裝有高(gao)(gao)(gao)壓(ya)硅堆,串接在高(gao)(gao)(gao)壓(ya)回路(lu)中(zhong)作(zuo)半波整流,以獲得直(zhi)流高(gao)(gao)(gao)電(dian)壓(ya)。當用一短(duan)(duan)路(lu)桿將高(gao)(gao)(gao)壓(ya)硅堆短(duan)(duan)接時(shi),可獲得工(gong)頻高(gao)(gao)(gao)電(dian)壓(ya),作(zuo)為(wei)交流輸(shu)出狀(zhuang)態;取消短(duan)(duan)路(lu)桿時(shi),作(zuo)為(wei)直(zhi)流輸(shu)出狀(zhuang)態。
圖中:D—短路(lu)桿(gan) VD—高壓(ya)硅(gui)堆
試驗變壓器高壓套管中的高壓硅(gui)堆未畫出,其原理(li)與(yu)上(shang)圖相同。
三(san)(san)(san)臺試(shi)(shi)(shi)(shi)(shi)驗(yan)變(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)串(chuan)(chuan)(chuan)級(ji)(ji)(ji)(ji)獲(huo)得更高(gao)電(dian)(dian)壓(ya)(ya)(ya)(ya)的(de)(de)接(jie)線原理見圖4。串(chuan)(chuan)(chuan)級(ji)(ji)(ji)(ji)高(gao)壓(ya)(ya)(ya)(ya)試(shi)(shi)(shi)(shi)(shi)驗(yan)變(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)有很(hen)大的(de)(de)優越性,因為(wei)整個試(shi)(shi)(shi)(shi)(shi)驗(yan)裝(zhuang)(zhuang)置由幾臺單(dan)臺試(shi)(shi)(shi)(shi)(shi)驗(yan)變(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)組(zu)成,單(dan)臺試(shi)(shi)(shi)(shi)(shi)驗(yan)變(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)容量(liang)小、電(dian)(dian)壓(ya)(ya)(ya)(ya)低、重量(liang)輕(qing),便于運輸和(he)安裝(zhuang)(zhuang)。它(ta)既然可(ke)串(chuan)(chuan)(chuan)接(jie)成高(gao)出(chu)幾倍的(de)(de)單(dan)臺試(shi)(shi)(shi)(shi)(shi)驗(yan)變(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)輸出(chu)電(dian)(dian)壓(ya)(ya)(ya)(ya)組(zu)合使用,又可(ke)分開成幾套(tao)單(dan)臺試(shi)(shi)(shi)(shi)(shi)驗(yan)變(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)單(dan)獨(du)使用。整套(tao)裝(zhuang)(zhuang)置投資(zi)小,經濟(ji)實惠。圖5中(zhong)(zhong),在(zai)(zai)第(di)(di)**和(he)**級(ji)(ji)(ji)(ji)的(de)(de)每個單(dan)元(yuan)試(shi)(shi)(shi)(shi)(shi)驗(yan)變(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)中(zhong)(zhong)都(dou)有一個勵磁繞(rao)(rao)組(zu)A1、C1和(he)A2、C2。在(zai)(zai)三(san)(san)(san)臺串(chuan)(chuan)(chuan)級(ji)(ji)(ji)(ji)試(shi)(shi)(shi)(shi)(shi)驗(yan)變(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)基本(ben)原理中(zhong)(zhong),低壓(ya)(ya)(ya)(ya)電(dian)(dian)源加在(zai)(zai)試(shi)(shi)(shi)(shi)(shi)驗(yan)變(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)Ⅰ的(de)(de)初級(ji)(ji)(ji)(ji)繞(rao)(rao)組(zu)a1x1上,單(dan)臺試(shi)(shi)(shi)(shi)(shi)驗(yan)變(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)Ⅰ、Ⅱ、Ⅲ的(de)(de)輸出(chu)電(dian)(dian)壓(ya)(ya)(ya)(ya)都(dou)是V。勵磁繞(rao)(rao)組(zu)A1、C1給**級(ji)(ji)(ji)(ji)試(shi)(shi)(shi)(shi)(shi)驗(yan)變(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)Ⅱ的(de)(de)初級(ji)(ji)(ji)(ji)繞(rao)(rao)組(zu)供電(dian)(dian);**級(ji)(ji)(ji)(ji)試(shi)(shi)(shi)(shi)(shi)驗(yan)變(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)Ⅱ的(de)(de)勵磁繞(rao)(rao)組(zu)A2、C2給第(di)(di)三(san)(san)(san)級(ji)(ji)(ji)(ji)試(shi)(shi)(shi)(shi)(shi)驗(yan)變(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)Ⅲ的(de)(de)初級(ji)(ji)(ji)(ji)繞(rao)(rao)組(zu)供電(dian)(dian)。**級(ji)(ji)(ji)(ji)試(shi)(shi)(shi)(shi)(shi)驗(yan)變(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)Ⅱ和(he)第(di)(di)三(san)(san)(san)級(ji)(ji)(ji)(ji)試(shi)(shi)(shi)(shi)(shi)驗(yan)變(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)Ⅲ的(de)(de)箱(xiang)體(ti)分別(bie)處在(zai)(zai)對(dui)地(di)為(wei)1V和(he)2V的(de)(de)高(gao)電(dian)(dian)位上,所以箱(xiang)體(ti)對(dui)地(di)是絕緣(yuan)的(de)(de),試(shi)(shi)(shi)(shi)(shi)驗(yan)變(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)Ⅰ的(de)(de)箱(xiang)體(ti)是接(jie)地(di)的(de)(de)。這樣第(di)(di)**、**級(ji)(ji)(ji)(ji)、第(di)(di)三(san)(san)(san)級(ji)(ji)(ji)(ji)試(shi)(shi)(shi)(shi)(shi)驗(yan)變(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)對(dui)地(di)的(de)(de)額定輸出(chu)電(dian)(dian)壓(ya)(ya)(ya)(ya)分別(bie)為(wei)1V、2V、3V;其額定容量(liang)分別(bie)為(wei)3P、2P、1P。
YDQ系(xi)列(lie)高壓(ya)(ya)試驗(yan)變壓(ya)(ya)器做被試品的工(gong)頻(pin)耐壓(ya)(ya)試驗(yan)使用接(jie)線原(yuan)理圖(tu)(tu)見(jian)圖(tu)(tu)5。
圖中:R1—限流電阻(zu)(zu) FRC—阻(zu)(zu)容分壓器(qi) RF—球間隙保護電阻(zu)(zu) G—球間隙 CX—被試品(pin)
注:高(gao)壓尾必須可(ke)靠接地
工頻耐壓(ya)試驗中限流(liu)電阻(zu)(zu)R1應(ying)根據試驗變壓(ya)器的額(e)定容量來選(xuan)擇。如高(gao)壓(ya)側額(e)定輸出(chu)電流(liu)在100~300mA時(shi),可取0.5~1Ω/V(試驗電壓(ya));高(gao)壓(ya)側額(e)定輸出(chu)電流(liu)為1A以(yi)上時(shi),可取1Ω/V(試驗電壓(ya))。常用水電阻(zu)(zu)作為限流(liu)電阻(zu)(zu),管子長(chang)度可按150kV/m考慮,管子粗細應(ying)具有足夠(gou)的熱容量(水阻(zu)(zu)液配(pei)制(zhi)方法:用蒸餾水加(jia)入適(shi)量硫酸銅配(pei)制(zhi)成各種不(bu)同的阻(zu)(zu)值)。
球間(jian)隙(xi)(xi)及保(bao)(bao)護(hu)電(dian)阻:當電(dian)壓超過球間(jian)隙(xi)(xi)整定值時(一般取(qu)試驗電(dian)壓的110%~120%),球間(jian)隙(xi)(xi)放電(dian),對(dui)被(bei)試品起到(dao)保(bao)(bao)護(hu)作用。球間(jian)隙(xi)(xi)保(bao)(bao)護(hu)電(dian)阻可按(an)1Ω/V(試驗電(dian)壓)選取(qu)。
在工(gong)頻(pin)耐壓(ya)(ya)(ya)(ya)試(shi)(shi)(shi)(shi)驗(yan)中,低電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)側測(ce)(ce)量(liang)電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(儀表(biao)電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya))不是(shi)(shi)非(fei)常(chang)準確的,其原因是(shi)(shi)由于(yu)試(shi)(shi)(shi)(shi)驗(yan)變壓(ya)(ya)(ya)(ya)器存在著漏(lou)抗,在這個漏(lou)抗上(shang)必然存在著壓(ya)(ya)(ya)(ya)降(jiang)或(huo)容升,使試(shi)(shi)(shi)(shi)品(pin)(pin)上(shang)的電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)低于(yu)或(huo)高于(yu)低壓(ya)(ya)(ya)(ya)側測(ce)(ce)量(liang)電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)表(biao)上(shang)反映出(chu)來的電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)。工(gong)頻(pin)耐壓(ya)(ya)(ya)(ya)試(shi)(shi)(shi)(shi)驗(yan)時,被(bei)試(shi)(shi)(shi)(shi)品(pin)(pin)上(shang)的電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)高于(yu)試(shi)(shi)(shi)(shi)驗(yan)變壓(ya)(ya)(ya)(ya)器的輸出(chu)電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya),也就是(shi)(shi)所謂容升現象。感應耐壓(ya)(ya)(ya)(ya)試(shi)(shi)(shi)(shi)驗(yan)時,試(shi)(shi)(shi)(shi)驗(yan)變壓(ya)(ya)(ya)(ya)器的漏(lou)抗必然存在著壓(ya)(ya)(ya)(ya)降(jiang)。為了(le)準確測(ce)(ce)量(liang)被(bei)試(shi)(shi)(shi)(shi)品(pin)(pin)上(shang)所施加(jia)的電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya),因此常(chang)在高壓(ya)(ya)(ya)(ya)側接入(ru)FRC阻容分壓(ya)(ya)(ya)(ya)器來測(ce)(ce)量(liang)電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(見圖5)。
工頻耐壓試驗操作(zuo)注意事項
1)試驗(yan)人(ren)員應做好分工,明(ming)確相(xiang)互間聯系方法(fa)。并(bing)有(you)專門人(ren)監護(hu)現場**及觀(guan)察試品(pin)狀態。
2)被(bei)試(shi)品(pin)應先清掃干凈,并**干燥,以免損(sun)壞被(bei)試(shi)品(pin)和(he)試(shi)驗帶(dai)來的誤差(cha)。
3)對于大型(xing)試驗,一(yi)般都應先進行空升試驗。即不接試品時升壓至試驗電壓,校對各種表計,調(diao)整(zheng)球間隙。
4)升壓速度不能太快,并(bing)必須防(fang)止突(tu)然加(jia)壓。例如(ru)調壓器(qi)(qi)不在零位時突(tu)然合閘(zha)。也不能突(tu)然切斷電源,一(yi)般應在調壓器(qi)(qi)降至零位時拉閘(zha)。
5)當電(dian)(dian)壓(ya)升至試驗電(dian)(dian)壓(ya)時,開(kai)始計時,到1min后,迅速降壓(ya)到1/3試驗電(dian)(dian)壓(ya)以下時,才能拉開(kai)電(dian)(dian)源。
6)在升壓(ya)或耐壓(ya)試(shi)驗過程中,如(ru)發(fa)現下列(lie)不正(zheng)常情(qing)況時,應立即(ji)降壓(ya),切(qie)斷(duan)電源。停止(zhi)試(shi)驗并(bing)查明原因(yin):①電壓(ya)表指針擺動(dong)很大;②發(fa)現絕緣燒焦或冒煙;③被(bei)試(shi)品內有不正(zheng)常的聲音(yin)。
7)耐(nai)壓試(shi)驗前后(hou)應(ying)測(ce)量絕緣(yuan)電阻(zu),檢查絕緣(yuan)情況。
試(shi)驗(yan)變壓(ya)器(qi)在做被試(shi)品的直(zhi)流耐壓(ya)或泄(xie)露試(shi)驗(yan)時接線原理圖(tu)如圖(tu)6。
注:此(ci)試驗應先抽出短路桿“D”,圖(tu)6中所(suo)示。
圖中:VD—高壓硅堆 R1—限流電阻(zu) C1—高壓濾波電容 FRC—阻(zu)容分壓器 CX—被試品(pin) μA—帶保護微安表
泄露(lu)試(shi)驗中限(xian)(xian)流(liu)(liu)(liu)電(dian)阻R1選擇在額定輸(shu)出電(dian)壓(ya)時(shi),輸(shu)出端短(duan)路(lu)電(dian)流(liu)(liu)(liu)不超過(guo)高(gao)壓(ya)硅堆的*大整(zheng)流(liu)(liu)(liu)。如電(dian)壓(ya)硅堆的*大整(zheng)流(liu)(liu)(liu)電(dian)流(liu)(liu)(liu)為100mA時(shi)用于(yu)60kV的試(shi)驗裝置(zhi)中,限(xian)(xian)流(liu)(liu)(liu)電(dian)阻按R1=60/0.1=600kΩ選擇。限(xian)(xian)流(liu)(liu)(liu)電(dian)阻還應具(ju)有(you)足夠的容量和沿面放電(dian)距離(li)。
高壓濾波電容C1一(yi)般選擇在0.01~0.1μF,當被試(shi)品(pin)的(de)電容量(liang)很(hen)大時,C1可省略不(bu)用。
泄露試驗的操作及(ji)注意事項(xiang)
1)試驗(yan)前應先檢(jian)查被試品是否停電,接地放電,一切對外連線是否擦干凈。要嚴防將試驗(yan)電壓加(jia)到有人工作的(de)部位上去。
2)接(jie)好試驗裝置(zhi)的接(jie)線(xian)后(hou),應復查無誤后(hou)才可加(jia)壓(ya)。應特(te)別注意檢(jian)查高壓(ya)設(she)備及引線(xian)與(yu)地(di)(di)、與(yu)操作人員的**距離,被試品的外殼是否可靠接(jie)地(di)(di),要按**規程(cheng)中所規定的內容進行(xing)試驗。
3)對于大(da)電(dian)(dian)容量設備應緩慢升壓,防止被試品的充電(dian)(dian)電(dian)(dian)流燒壞微安(an)表(biao)。必要(yao)時應分(fen)級(ji)加壓,分(fen)別讀取(qu)各(ge)級(ji)電(dian)(dian)壓下(xia)微安(an)表(biao)的穩(wen)定讀數。
4)試(shi)(shi)驗(yan)(yan)過程中(zhong),應密(mi)切監視被試(shi)(shi)品(pin)、試(shi)(shi)驗(yan)(yan)裝(zhuang)置、微(wei)安表,一旦發(fa)生擊穿、閃爍(shuo)等異(yi)常(chang)現(xian)象應立即降壓,切斷電源,并查明原因,詳(xiang)細記錄。
5)試驗完畢,降壓(ya),切斷(duan)電(dian)源后應將被試品及試驗裝置本身充分(fen)放電(dian)。
四(si)、注意事項
1、按(an)照(zhao)您(nin)所進行的(de)試驗(yan)接好工(gong)作線路。試驗(yan)變壓(ya)器的(de)外(wai)殼以(yi)及操作系統的(de)外(wai)殼必須(xu)(xu)可靠接地(di)。試驗(yan)變壓(ya)器高(gao)壓(ya)繞組(zu)(zu)的(de)X端(duan)(高(gao)壓(ya)尾)以(yi)及測量繞組(zu)(zu)的(de)F端(duan)必須(xu)(xu)可靠接地(di)。
2、做串級(ji)試(shi)驗(yan)時(shi),**級(ji)、第(di)(di)三(san)級(ji)試(shi)驗(yan)變(bian)壓(ya)器(qi)的(de)低(di)壓(ya)繞組(zu)的(de)X端(duan),測量繞組(zu)的(de)F端(duan)以及高壓(ya)繞組(zu)的(de)X端(duan)(高壓(ya)尾)均接本級(ji)試(shi)驗(yan)變(bian)壓(ya)器(qi)的(de)外殼。**級(ji)、第(di)(di)三(san)級(ji)試(shi)驗(yan)變(bian)壓(ya)器(qi)的(de)外殼必須(xu)通過(guo)絕(jue)緣支架接地。
3、接通電(dian)源前,操(cao)作系(xi)統(tong)的調壓器必須調到零位后(hou)方(fang)可接通電(dian)源,合閘,開始(shi)升壓。
4、從(cong)零開(kai)始(shi)均勻旋(xuan)轉調壓(ya)(ya)(ya)器手輪升(sheng)(sheng)壓(ya)(ya)(ya)。升(sheng)(sheng)壓(ya)(ya)(ya)方法(fa)有:快速升(sheng)(sheng)壓(ya)(ya)(ya)法(fa),即(ji)20s逐(zhu)級升(sheng)(sheng)壓(ya)(ya)(ya)法(fa);慢速升(sheng)(sheng)壓(ya)(ya)(ya)法(fa),即(ji)60s逐(zhu)級升(sheng)(sheng)壓(ya)(ya)(ya)法(fa);極(ji)慢速升(sheng)(sheng)壓(ya)(ya)(ya)法(fa)供選用。電(dian)壓(ya)(ya)(ya)從(cong)零開(kai)始(shi)按一定(ding)的(de)(de)升(sheng)(sheng)壓(ya)(ya)(ya)方式和速度(du)上升(sheng)(sheng)到(dao)您所(suo)(suo)需的(de)(de)額定(ding)試(shi)(shi)驗電(dian)壓(ya)(ya)(ya)的(de)(de)75%后,在(zai)以(yi)每秒2%額定(ding)試(shi)(shi)驗電(dian)壓(ya)(ya)(ya)的(de)(de)速度(du)升(sheng)(sheng)到(dao)您所(suo)(suo)需的(de)(de)額定(ding)電(dian)壓(ya)(ya)(ya),并密(mi)切(qie)注意(yi)測量儀(yi)表的(de)(de)指(zhi)示(shi)以(yi)及(ji)被試(shi)(shi)品的(de)(de)情況(kuang)。升(sheng)(sheng)壓(ya)(ya)(ya)過程中或試(shi)(shi)驗過程中如(ru)發現測量儀(yi)表的(de)(de)指(zhi)示(shi)及(ji)被試(shi)(shi)品情況(kuang)異常,應立(li)即(ji)降壓(ya)(ya)(ya),切(qie)斷電(dian)源,查明情況(kuang)。
5、試驗(yan)完(wan)畢后,應在(zai)數秒內勻速的將調壓(ya)器返回至零位,然后切斷電源。
6、本產(chan)品(pin)不得(de)超過額定(ding)參數使(shi)用。除試(shi)驗(yan)必須外,決(jue)不允許(xu)全電壓通電或斷電。
7、 再升壓(ya)或耐(nai)壓(ya)試驗過程中,如發現以(yi)下不正常情況時,應立即降(jiang)壓(ya),切斷(duan)電源(yuan),停止試驗并查(cha)明原因。
⑴電(dian)壓表指針(zhen)擺動(或數字跳動)很大
⑵電流表(biao)直(zhi)線上升
被試品內有(you)不正常的(de)聲音
8、圖1中第9項系壓(ya)力(li)閥及壓(ya)力(li)表,為(wei)長期關閉狀(zhuang)態。每6個月開閥一次,以檢(jian)查(cha)SF6壓(ya)力(li),應(ying)不(bu)小(xiao)于(yu)0.2MPa(檢(jian)查(cha)壓(ya)力(li)后立即(ji)關閉閥門),低于(yu)0.2MPa時應(ying)加SF6氣(qi)體,以增加氣(qi)絕緣。
9、耐壓實(shi)驗前(qian)后應測(ce)量被(bei)試設備的絕緣電阻,檢(jian)查絕緣情(qing)況。
10、當試驗變(bian)壓器長期不(bu)使用時,應放置于通風、干燥、無陽光(guang)直(zhi)射(she)的地方。
11、該產品不允許(xu)在高(gao)于45℃的(de)溫度下(xia)長期(qi)存放、使用(yong)、放氣。
12、運(yun)輸搬運(yun)途中不(bu)得(de)重(zhong)力沖擊。
13、產品緊固(gu)件及壓力閥、壓力表不得擅自松(song)動。
14、使(shi)用本(ben)產品做(zuo)高壓試驗(yan)時,出熟悉本(ben)說明書(shu)外,還必須(xu)嚴(yan)格執行國(guo)家有關標準(zhun)和操作規程(cheng)。可參照GB311-83《高壓輸變設(she)備的絕緣配合,高壓試驗(yan)技術》;《電氣設(she)備預防性試驗(yan)規程(cheng)》等。
五、試驗(yan)變壓器(qi)的容量選擇(ze)
標稱試驗變(bian)壓(ya)器容量Pn的(de)確定公式:Pn=kVn 2ωCt×10-9
式中:
Pn——標稱試(shi)驗變(bian)壓(ya)器(qi)容量(kVA)
Vn——試(shi)驗變壓器的額定輸(shu)出高壓的有效值(kV)
k ——**系(xi)數。k≥1,標(biao)稱電壓Vn≥1MV時(shi),k=2;標(biao)稱電壓較(jiao)低(di)時(shi),k值可(ke)取高一(yi)些。
Ct——被(bei)試品的電容量(pF)
ω——角頻(pin)率,ω=2πf,f——試驗電源(yuan)的頻(pin)率
被試(shi)設備(bei)的電容量Ct可(ke)由交流電橋測出。Ct的變化(hua)很大,
可由設備的類型而定。
典型(xing)數據如下:
簡單的(de)棒式或(huo)懸式絕緣子 幾(ji)十微法
簡單的分級(ji)套管 100~1000pF
電壓互(hu)感器 200 ~ 500pF
電力變(bian)壓器 < 1000kVA~1000pF
> 1000kVA 1000~10000pF
高壓電力(li)電纜和油浸紙(zhi)絕緣 250~300pF/m
氣體絕緣 ~60pF/m
封閉變電(dian)站,SF6氣體絕緣(yuan) 100~10000Pf;
對于(yu)不同(tong)的試驗電壓Vn,選(xuan)擇(ze)不同(tong)的(適當的)**系數(shu)k。
以(yi)下列出不同的(de)Vn所選用的(de)k值供參考。
Vn =50~100kV k = 4
Vn =150~300kV k = 3
Vn > 300kV k = 2
一(yi)、概述(shu)
工(gong)頻耐壓試驗(yan)是鑒定電力設備(bei)絕緣強(qiang)度的*嚴格(ge)、*有效(xiao)和*直接的方法。它能檢查出那些危險(xian)性較大的集中缺陷(xian),對判(pan)斷電力設備(bei)能否(fou)繼續參加運行(xing)具有決定性作用,是保證設備(bei)絕緣水平、避免發生絕緣事故的重要手段(duan)。
本裝置是(shi)根(gen)據國家(jia)*新電(dian)(dian)力(li)行業標(biao)準而設計的(de)、性能(neng)先進的(de)耐(nai)壓試驗設備,用于(yu)對各種(zhong)電(dian)(dian)器產品、電(dian)(dian)氣(qi)元(yuan)件、絕緣(yuan)(yuan)材料等進行規定電(dian)(dian)壓下的(de)絕緣(yuan)(yuan)強度試驗,以考核產品的(de)絕緣(yuan)(yuan)水平,發現被(bei)試品的(de)絕緣(yuan)(yuan)缺陷(xian),衡(heng)量過電(dian)(dian)壓的(de)能(neng)力(li)。
二、產品特點
監(jian)視功(gong)能:高壓(ya)電(dian)壓(ya) 低壓(ya)電(dian)流 零位指(zhi)示 電(dian)源指(zhi)示 工(gong)作(zuo)指(zhi)示 計時指(zhi)示
保(bao)護(hu)功能:過流保(bao)護(hu)、零位啟動保(bao)護(hu)、聲光語言報(bao)警提醒
采用新型時間繼電器(qi),計時范圍更廣(1S~99H)
采用新(xin)型電流繼(ji)電器,更**、更可靠(kao),確保人身及設備(bei)**。
試(shi)驗(yan)變壓器高壓線(xian)圈為圓筒多層塔式,由上(shang)等聚酯漆包線(xian)及高耐(nai)壓值絕緣材料繞制而成。
試驗變壓器(5kVA以上)裝有可移動的鐵輪。具有重(zhong)量輕、體(ti)積小、移動方便、性能優越等特點。
三、設備組成
1、選(xuan)型配置
標(biao)準配置
|
□ 分體式
|
操(cao)作部(bu)分:
□箱式(shi)(不大于(yu)5kVA) / □臺式(shi)
容(rong)量: kVA(小(xiao)于200kVA)
輸入:□AC220V / □AC380V
|
試驗變壓(ya)器(qi):
□交流 / □交直流
□油變(bian) / □干(gan)變(bian) / □氣變(bian)
容量: kVA(小于200kVA)
輸出(chu):AC kV(小于300kVA)
|
□ 一體式
|
□箱式(shi)(不大于(yu)20kV) / □臺式(shi)(不大于(yu)30kV)
容量: kVA(小(xiao)于(yu)300kVA)
輸入:□AC220V / □AC380V 輸出:AC kV(不大于30kV)
|
客(ke)戶(hu)選配
|
□標準(zhun)高壓分壓器(qi)
|
□保護球隙(xi)
|
□直流微安表
|
□放**
|
□保(bao)護水阻
|
□高壓濾(lv)波電容
|
其(qi)它:
|
2、對應(ying)實物
四、技術指標(biao)
1、使用條件:
(1)工(gong)作(zuo)場所應無(wu)嚴重影響絕緣的氣(qi)體、蒸汽、化學性(xing)(xing)塵埃及其它爆(bao)炸性(xing)(xing)和腐(fu)蝕性(xing)(xing)介質。
(2)環境(jing)溫度 -20~+50℃
(3)環境濕度 ≤85% RH(無凝結水)
2、控制箱(臺(tai))參(can)數:(常(chang)規參(can)數見下表)
規格
|
容量(liang)
|
輸 入 電(dian) 源
|
輸 出(chu) 電(dian) 壓(ya)
|
重量(kg)
|
相數
|
(V)
|
(A)
|
(V)
|
(A)
|
2/220
|
2
|
1
|
220
|
10
|
0-250
|
8
|
14
|
3/220
|
3
|
1
|
220
|
15
|
0-250
|
12
|
16
|
5/220
|
5
|
1
|
220
|
25
|
0-250
|
20
|
18
|
10/220
|
10
|
1
|
220
|
50
|
0-250
|
40
|
80
|
15/380
|
15
|
2
|
380
|
37.5
|
0-430
|
34.8
|
90
|
20/380
|
20
|
2
|
380
|
50
|
0-430
|
46.5
|
100
|
25/380
|
25
|
2
|
380
|
62.5
|
0-430
|
58.1
|
120
|
30/380
|
30
|
2
|
380
|
75
|
0-430
|
69.7
|
140
|
50/380
|
50
|
2
|
380
|
125
|
0-430
|
116.2
|
160
|
100/380
|
100
|
2
|
380
|
250
|
0-430
|
232.5
|
250
|
說(shuo)明:如有特殊參數要求,可(ke)按用戶的技術參數進行設計制(zhi)作。
3、試驗變壓器(qi)參(can)數:(常規參(can)數見下(xia)表)
規(gui)格
|
容(rong)量
kVA
|
低(di)壓側
|
高(gao)壓側(ce)
|
高壓側(ce)(交直流變壓器)
|
測量變比(bi)
|
60分鐘溫升℃
|
阻抗電壓%
|
空載電(dian)流
%
|
質量
kg
|
電壓
V
|
電(dian)流
A
|
交流(liu)輸出
|
直流輸出
|
電壓kV
|
電流
|
電壓kV
|
電流(liu)
|
1.5/50
|
1.5
|
200
|
7.5
|
50
|
30
|
70
|
21.4
|
500
|
50
|
10
|
<4
|
19.5
|
3/50
|
3
|
200
|
15
|
50
|
60
|
70
|
42.9
|
500
|
50
|
10
|
<4
|
27
|
5/50
|
5
|
200
|
25
|
50
|
100
|
70
|
71.4
|
500
|
50
|
10
|
<4
|
52
|
10/50
|
10
|
200
|
50
|
50
|
200
|
70
|
142.9
|
500
|
50
|
10
|
<4
|
80
|
15/50
|
15
|
400
|
37.5
|
50
|
300
|
70
|
214.3
|
500
|
50
|
8
|
<4
|
120
|
20/50
|
20
|
400
|
50
|
50
|
400
|
70
|
285.7
|
500
|
50
|
8
|
<4
|
140
|
30/50
|
30
|
400
|
75
|
50
|
600
|
70
|
428.6
|
500
|
50
|
8
|
<4
|
155
|
50/50
|
50
|
400
|
125
|
50
|
1000
|
70
|
714.3
|
500
|
50
|
8
|
<4
|
184
|
10/100
|
10
|
200
|
50
|
100
|
100
|
140
|
71.4
|
1000
|
50
|
10
|
<4
|
135
|
15/100
|
15
|
400
|
37.5
|
100
|
150
|
140
|
107.1
|
1000
|
50
|
8
|
<4
|
150
|
20/100
|
20
|
400
|
50
|
100
|
200
|
140
|
142.9
|
1000
|
50
|
8
|
<4
|
215
|
30/100
|
30
|
400
|
75
|
100
|
300
|
140
|
214.3
|
1000
|
50
|
8
|
<4
|
250
|
50/100
|
50
|
400
|
125
|
100
|
500
|
140
|
357.1
|
1000
|
50
|
8
|
<4
|
290
|
10/150
|
10
|
200
|
50
|
100
|
66.7
|
140
|
47.6
|
1500
|
50
|
10
|
<4
|
180
|
15/150
|
15
|
400
|
37.5
|
150
|
100
|
210
|
71.4
|
1500
|
50
|
8
|
<4
|
200
|
20/150
|
30
|
400
|
50
|
150
|
133.3
|
210
|
95.2
|
1500
|
50
|
8
|
<4
|
220
|
30/150
|
30
|
400
|
75
|
150
|
200
|
210
|
142.9
|
1500
|
50
|
8
|
<4
|
280
|
50/150
|
50
|
400
|
125
|
150
|
333.3
|
210
|
238.1
|
1500
|
50
|
8
|
<4
|
340
|
說明:如(ru)有特殊參數要(yao)求,可(ke)按(an)用戶的技術(shu)參數進行設計制作。
上表的重量(liang)以油(you)浸(jin)式(shi)(shi)(shi)試驗變(bian)壓(ya)器(qi)(qi)為例,干式(shi)(shi)(shi)試驗變(bian)壓(ya)器(qi)(qi)和(he)充氣(qi)式(shi)(shi)(shi)試驗變(bian)壓(ya)器(qi)(qi)稍有不同(tong)。
五(wu)、接線及工作(zuo)原理
1、調壓部(bu)分接(jie)線及原理
調(diao)壓(ya)部(bu)分由(you)控制部(bu)分和試驗(yan)變壓(ya)器組(zu)(zu)成。控制部(bu)分是(shi)由(you)接(jie)觸式(shi)調(diao)壓(ya)器及(ji)其控制、保護、測(ce)量、信(xin)號電路組(zu)(zu)成。試驗(yan)變壓(ya)器由(you)低(di)壓(ya)繞組(zu)(zu)、高壓(ya)繞組(zu)(zu)、儀表繞組(zu)(zu)三部(bu)分組(zu)(zu)成。
試(shi)驗(yan)(yan)變(bian)(bian)壓器為交直流兩用時,試(shi)驗(yan)(yan)變(bian)(bian)壓器配(pei)置(zhi)了高(gao)壓硅(gui)堆(油(you)(you)變(bian)(bian)、氣(qi)變(bian)(bian)為內置(zhi),干變(bian)(bian)為外(wai)置(zhi)),高(gao)壓可輸(shu)出(chu)(chu)(chu)交流和直流。輸(shu)出(chu)(chu)(chu)交流時,要(yao)求接(jie)入短路桿(gan)(油(you)(you)變(bian)(bian)、氣(qi)變(bian)(bian))或去掉(diao)外(wai)置(zhi)硅(gui)堆(干變(bian)(bian));輸(shu)出(chu)(chu)(chu)直流時,要(yao)求擰出(chu)(chu)(chu)短路桿(gan)(油(you)(you)變(bian)(bian)、氣(qi)變(bian)(bian))或加(jia)上外(wai)置(zhi)硅(gui)堆(干變(bian)(bian))
通過接入工(gong)(gong)頻電源,調節調壓(ya)(ya)器,以獲(huo)得所需(xu)要的試驗高壓(ya)(ya)電壓(ya)(ya)值。其工(gong)(gong)作原理(li)見圖1:
2、試驗部分接線及原理
做耐壓(ya)試驗時,控制部(bu)分、變壓(ya)器(qi)的接地(di)端及高壓(ya)尾必須(xu)可靠接地(di)。有條件的情況下,做工(gong)頻耐壓(ya)試驗請加上限流電阻、標準高壓(ya)分壓(ya)器(qi)、球隙(xi)保護電阻及保護球隙(xi),如圖3。
做直流耐壓(ya)試驗請另外加上(shang)微安表(biao),微安表(biao)必須(xu)接在(zai)硅(gui)堆(dui)和被試器(qi)之間(jian),油(you)(you)變(bian)(bian)或氣(qi)變(bian)(bian)一般擰(ning)(ning)在(zai)高壓(ya)頭上(shang)面(要求擰(ning)(ning)出短路(lu)桿),干變(bian)(bian)擰(ning)(ning)在(zai)外置硅(gui)堆(dui)上(shang)面;為了更(geng)準確顯示高壓(ya)直流泄漏電(dian)流,請將分壓(ya)器(qi)的(de)高壓(ya)線接在(zai)微安表(biao)和硅(gui)堆(dui)之間(jian),(油(you)(you)變(bian)(bian)、氣(qi)變(bian)(bian))如圖4,(干變(bian)(bian))如圖5。
耐壓(ya)試(shi)驗(yan)中(zhong)限流(liu)電(dian)(dian)阻R1應根(gen)據試(shi)驗(yan)變壓(ya)器的額定(ding)(ding)容量來(lai)選擇。如(ru)高壓(ya)側額定(ding)(ding)輸出(chu)電(dian)(dian)流(liu)在(zai)100~300mA時(shi),可(ke)(ke)取0.5~1Ω/V(試(shi)驗(yan)電(dian)(dian)壓(ya));高壓(ya)側額定(ding)(ding)輸出(chu)電(dian)(dian)流(liu)為(wei)1A以上時(shi),可(ke)(ke)取1Ω/V(試(shi)驗(yan)電(dian)(dian)壓(ya))。常用(yong)水(shui)電(dian)(dian)阻作(zuo)為(wei)限流(liu)電(dian)(dian)阻,管子長度可(ke)(ke)按150kV/m考慮,管子粗(cu)細應具(ju)有(you)足夠的熱(re)容量(水(shui)阻液配(pei)制方法:用(yong)蒸餾水(shui)加入(ru)適(shi)量硫酸銅配(pei)制成各種不(bu)同的阻值(zhi))。
球間隙及保護電(dian)(dian)阻:當電(dian)(dian)壓(ya)超過球間隙整定(ding)值時(shi)(一(yi)般取試(shi)驗電(dian)(dian)壓(ya)的110%~120%),球間隙放電(dian)(dian),對被試(shi)品起到保護作用。球間隙保護電(dian)(dian)阻可(ke)按1Ω/V(試(shi)驗電(dian)(dian)壓(ya))選取。
在工頻(pin)耐(nai)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)試(shi)(shi)驗(yan)(yan)中,低電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)側(ce)測(ce)量(liang)(liang)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(儀表電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya))不是非常準確的(de),其原因(yin)是由于(yu)試(shi)(shi)驗(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)存(cun)(cun)在著(zhu)漏抗(kang),在這個(ge)漏抗(kang)上(shang)(shang)(shang)必(bi)然存(cun)(cun)在著(zhu)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)降或容升,使試(shi)(shi)品上(shang)(shang)(shang)的(de)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)低于(yu)或高(gao)于(yu)低壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)側(ce)測(ce)量(liang)(liang)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)表上(shang)(shang)(shang)反映出(chu)(chu)來(lai)的(de)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)。工頻(pin)耐(nai)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)試(shi)(shi)驗(yan)(yan)時(shi)(shi),被試(shi)(shi)品上(shang)(shang)(shang)的(de)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)高(gao)于(yu)試(shi)(shi)驗(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)的(de)輸(shu)出(chu)(chu)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya),也就是所謂容升現象。感應耐(nai)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)試(shi)(shi)驗(yan)(yan)時(shi)(shi),試(shi)(shi)驗(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)的(de)漏抗(kang)必(bi)然存(cun)(cun)在著(zhu)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)降。為了準確測(ce)量(liang)(liang)被試(shi)(shi)品上(shang)(shang)(shang)所施(shi)加的(de)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya),因(yin)此常在高(gao)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)側(ce)接入標準高(gao)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)分壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)來(lai)測(ce)量(liang)(liang)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)。
五(wu)、面(mian)板結構說明
1、操(cao)作箱面板
控(kong)制(zhi)箱(xiang)為箱(xiang)式鋁(lv)合金結構,面板(ban)采(cai)用(yong)拉(la)絲鋁(lv)合金工藝(yi),所有電器元件(jian)(jian)均(jun)裝(zhuang)在(zai)骨架上(shang),便于安裝(zhuang)和維修。面板(ban)元件(jian)(jian)布置(zhi)如(ru)下:
2、操作臺面板
操作臺(tai)為臺(tai)式結構,殼(ke)體為冷(leng)扎鋼板(ban)結構,面板(ban)采用鋁合(he)金拉絲工藝(yi),面板(ban)元件布置如下:
六(liu)、操作指南
本裝(zhuang)置在操(cao)作(zuo)之前應根(gen)據(ju)不同被試(shi)品(pin)的容量、電(dian)壓等級,先計算(suan)好(hao)*大工作(zuo)電(dian)流(liu),并調(diao)整電(dian)流(liu)保(bao)護器(qi)。其試(shi)驗接線應參考本說(shuo)明書中圖(tu)1、圖(tu)2、圖(tu)3、圖(tu)4、圖(tu)5,必(bi)須可靠接地。
1、操作要(yao)點
(1)試(shi)(shi)驗(yan)前,應(ying)了(le)解被(bei)試(shi)(shi)品的(de)試(shi)(shi)驗(yan)電壓(ya),同時了(le)解被(bei)試(shi)(shi)品的(de)其(qi)他試(shi)(shi)驗(yan)項(xiang)目及以前的(de)試(shi)(shi)驗(yan)結果。若被(bei)試(shi)(shi)品有缺陷或(huo)異常,應(ying)在(zai)消除后(hou)再進(jin)行耐壓(ya)試(shi)(shi)驗(yan)。
(2)試(shi)驗(yan)現(xian)場應(ying)圍好遮攔(lan)或圍繩(sheng),掛好標示牌,并派專人監護。
(3)試(shi)驗(yan)前,被試(shi)品表面(mian)應擦拭干凈,將(jiang)被試(shi)品的外殼和(he)非被試(shi)繞組可靠(kao)接地。被試(shi)品為新沖油(you)設備時(shi),應按《規(gui)程》規(gui)定使(shi)油(you)靜止一定時(shi)間再升壓,對110kV及(ji)以下的充(chong)油(you)電力(li)設備,在注滿(man)油(you)后靜置時(shi)間應不少于24小(xiao)時(shi),對220kV及(ji)330kV的充(chong)油(you)電力(li)設備,靜置時(shi)間應不少于48小(xiao)時(shi)。
(4)接好試驗(yan)接線后,應由有經驗(yan)的(de)人(ren)員檢查,確(que)認無誤后方可升壓。
(5)升壓(ya)前,首先檢(jian)查調壓(ya)器(qi)是否(fou)在零位。調壓(ya)器(qi)在零位方可升壓(ya)。
(6)升(sheng)壓(ya)(ya)(ya)過程中不(bu)僅要監(jian)視電(dian)(dian)壓(ya)(ya)(ya)表(biao)的變(bian)化(hua),還應監(jian)視電(dian)(dian)流表(biao)的變(bian)化(hua),以及被試品電(dian)(dian)流的變(bian)化(hua)。升(sheng)壓(ya)(ya)(ya)時(shi)要均(jun)勻(yun)升(sheng)壓(ya)(ya)(ya),不(bu)能太(tai)快。升(sheng)至規定試驗電(dian)(dian)壓(ya)(ya)(ya)時(shi),開始計算時(shi)間,時(shi)間到后,緩(huan)慢(man)均(jun)勻(yun)降(jiang)下(xia)電(dian)(dian)壓(ya)(ya)(ya)。絕不(bu)允許不(bu)降(jiang)壓(ya)(ya)(ya)就先跳開電(dian)(dian)源開關(guan)。
(7)試驗中(zhong)發現(xian)表針擺(bai)動或被試品有異常聲響、冒(mao)煙(yan)等應立即降下電(dian)壓(ya),拉開電(dian)源,在高壓(ya)側掛(gua)上接(jie)地線后,再查明原因(yin)。
(8)耐(nai)壓試驗(yan)前后均應測量被試品的絕緣電阻。
2、操作步驟
(1) 按試(shi)驗要求(qiu)將控制(zhi)部分、試(shi)驗變壓器、被試(shi)品正確接好(hao)線,必(bi)須可靠接地,請參考圖(tu)1、圖(tu)2、圖(tu)3、圖(tu)4、圖(tu)5。
(2) 根(gen)據試驗的要(yao)求,整定“時間繼(ji)電(dian)器(qi)”及“過流繼(ji)電(dian)器(qi)”。
A 時間(jian)繼電器設置:
T1,T2,T3,T4設(she)置0~9任意數字(zi),T可設(she)置為H(小時(shi)),M(分鐘),S(秒)。
根(gen)據(ju)試(shi)驗要(yao)求(qiu),在1S~99H內可以任意設置定時時間(jian)。
B 過流繼(ji)電器(qi)設置:
過流動作(zuo)設定值=過流繼電(dian)器(qi)刻度(du)盤讀數×測量(liang)變(bian)比(bi)×K,其中K為(wei)(wei)(wei)電(dian)流倍(bei)率(lv)/切(qie)除開關(guan)的狀態(tai)值,分(fen)別為(wei)(wei)(wei)X1,X2,OFF,電(dian)流倍(bei)率(lv)/切(qie)除開關(guan)處于×1,×2位置(zhi)時(shi),K值分(fen)別為(wei)(wei)(wei)1、2,切(qie)換(huan)為(wei)(wei)(wei)OFF擋時(shi),K值為(wei)(wei)(wei)+∞。(注:不要使用OFF檔,因為(wei)(wei)(wei)會使變(bian)壓器(qi)失去過流保護功能而導(dao)致設備損壞。測量(liang)變(bian)比(bi)為(wei)(wei)(wei)電(dian)流互感器(qi)的變(bian)比(bi),沒有電(dian)流互感器(qi)時(shi)為(wei)(wei)(wei)1)。
(3) 接(jie)入電源,此時,“電源燈(deng)(deng)(deng)”亮(liang)(liang),表(biao)示(shi)外部電源已引入。如“零(ling)位(wei)(wei)(wei)燈(deng)(deng)(deng)”亮(liang)(liang),表(biao)示(shi)調壓器(qi)(qi)在零(ling)位(wei)(wei)(wei)。如“零(ling)位(wei)(wei)(wei)燈(deng)(deng)(deng)”不亮(liang)(liang),應逆時針(zhen)旋轉調節(jie)調壓器(qi)(qi)手柄(bing)至“零(ling)位(wei)(wei)(wei)燈(deng)(deng)(deng)”亮(liang)(liang),表(biao)示(shi)可進行調壓操(cao)作。
(4)按“啟動按鈕”。此時,“送電燈(deng)(deng)(deng)”,“電源燈(deng)(deng)(deng)”和“零位燈(deng)(deng)(deng)”亮(liang);進入送電狀態。
(5)以2kV/S勻速順時(shi)針旋(xuan)轉調壓器手(shou)柄至被試品規定的耐(nai)壓值,并密切(qie)注視(shi)電流表(biao)(直(zhi)流耐(nai)壓試驗時(shi),同時(shi)密切(qie)注視(shi)直(zhi)流微安表(biao))。此時(shi),“電源燈”,“工作燈”亮;“零位燈”滅。
(6)根(gen)據試驗啟(qi)動(dong)“計時按(an)鈕”,計時開(kai)始,并(bing)注(zhu)意被試品的(de)情況。
(7)當耐(nai)壓計時(shi)到時(shi),操(cao)作臺(tai)自動聲光報警(jing)。應立即逆時(shi)針旋轉調壓器手柄至零位,按下停止按鈕(niu)和解除計時(shi)按鈕(niu)自鎖(suo)狀態。此時(shi)“電源(yuan)燈(deng)”, “零位燈(deng)”亮,“工作燈(deng)”滅。試驗(yan)即告完畢(bi)
(8)拔掉電(dian)源,拆除接(jie)線,試驗結束(shu)。
(9)在升壓或耐壓過程中,如發(fa)生(sheng)短(duan)路(lu)、閃絡(luo)、擊穿過流時(shi),過流繼電(dian)(dian)器(qi)動作(zuo),切斷(duan)(duan)主(zhu)回(hui)路(lu)。此時(shi)應將調壓器(qi)逆時(shi)針旋(xuan)轉(zhuan)至零位,切斷(duan)(duan)電(dian)(dian)源,并(bing)查明原因,并(bing)作(zuo)詳細記錄。
(10)試驗(yan)完畢(bi),降壓,切斷(duan)電源后應用放**將被試品及試驗(yan)裝置本(ben)身(shen)充(chong)分放電。
七、產(chan)品維護(hu)
1、開箱驗收時,應檢查(cha)主控回路接(jie)線是(shi)否松動,調(diao)壓器電刷是(shi)否接(jie)觸良好(hao);
2、長期不(bu)用時,使用前應用500V兆歐表測(ce)量絕緣電(dian)阻(zu),其阻(zu)值不(bu)低于0.5MΩ;
3、電源電壓(ya)應符合控制(zhi)箱(xiang)(臺)銘牌上的輸入電壓(ya)值;
4、本(ben)裝(zhuang)置設有過電流保護,出廠(chang)已調整為額定(ding)電流的50%。用于小負載時,應根據被試品的額定(ding)容量電流重新設定(ding);
5、使用完畢后,應關(guan)好(hao)控制箱(xiang)(臺)門(men),以(yi)保持控制箱(xiang)(臺)內(nei)部(bu)清潔。
八(ba)、注意(yi)事項
1、按照您(nin)所進(jin)行的(de)(de)試驗接(jie)好工(gong)作(zuo)線路(lu)。試驗變壓(ya)(ya)器(qi)(qi)的(de)(de)外殼以及操作(zuo)系統的(de)(de)外殼必(bi)須可靠(kao)接(jie)地(di)。試驗變壓(ya)(ya)器(qi)(qi)的(de)(de)高壓(ya)(ya)繞(rao)組的(de)(de)X端(duan)(高壓(ya)(ya)尾)以及測量繞(rao)組的(de)(de)F端(duan)必(bi)須可靠(kao)接(jie)地(di)。
2、做串級(ji)試(shi)驗(yan)時,**級(ji)、第三(san)級(ji)試(shi)驗(yan)變壓器(qi)(qi)的(de)低壓繞組成X端,測量繞組的(de)F端以及高壓繞組的(de)X端(高壓端)均(jun)接本級(ji)試(shi)驗(yan)變壓器(qi)(qi)具外(wai)殼。**級(ji)、第三(san)級(ji)試(shi)驗(yan)變壓器(qi)(qi)的(de)外(wai)殼必須通過絕緣支架(jia)接地(di)。
3、接通(tong)電(dian)(dian)(dian)源前(qian),操作系統的(de)(de)(de)調壓(ya)(ya)(ya)(ya)器必須調到零位后方(fang)可(ke)接通(tong)電(dian)(dian)(dian)源,合閘,開(kai)始(shi)升(sheng)(sheng)壓(ya)(ya)(ya)(ya)。從零開(kai)始(shi)勻速旋轉調壓(ya)(ya)(ya)(ya)器手輪升(sheng)(sheng)壓(ya)(ya)(ya)(ya)。升(sheng)(sheng)壓(ya)(ya)(ya)(ya)方(fang)式有:快速升(sheng)(sheng)壓(ya)(ya)(ya)(ya)法(fa)(fa),即20s逐級升(sheng)(sheng)壓(ya)(ya)(ya)(ya)法(fa)(fa);慢(man)速升(sheng)(sheng)壓(ya)(ya)(ya)(ya)法(fa)(fa),即60s逐級升(sheng)(sheng)壓(ya)(ya)(ya)(ya)法(fa)(fa);極慢(man)速升(sheng)(sheng)壓(ya)(ya)(ya)(ya)法(fa)(fa)供選用。電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)從零開(kai)始(shi)按(an)一定的(de)(de)(de)升(sheng)(sheng)壓(ya)(ya)(ya)(ya)方(fang)式和速度(du)上(shang)升(sheng)(sheng)到您所(suo)(suo)需的(de)(de)(de)額定試(shi)(shi)(shi)驗電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)的(de)(de)(de)75%后,再以每秒2%額定試(shi)(shi)(shi)驗電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)的(de)(de)(de)速度(du)升(sheng)(sheng)到您所(suo)(suo)需的(de)(de)(de)試(shi)(shi)(shi)驗電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya),并(bing)密(mi)切(qie)注意測(ce)量儀表的(de)(de)(de)及被試(shi)(shi)(shi)品(pin)的(de)(de)(de)情(qing)況。升(sheng)(sheng)壓(ya)(ya)(ya)(ya)過程中(zhong)或試(shi)(shi)(shi)驗過程中(zhong)如發現測(ce)量儀表的(de)(de)(de)指示及被試(shi)(shi)(shi)品(pin)情(qing)況異常(chang),應立即降壓(ya)(ya)(ya)(ya),切(qie)斷電(dian)(dian)(dian)源,查明情(qing)況。
4、試驗完畢后,應在數(shu)秒(miao)內勻速的將調(diao)壓器返回至(zhi)零位(wei),然后切斷電源。本產品不(bu)得超(chao)過(guo)額定(ding)參(can)數(shu)使用(yong)。
5、使用本(ben)產品做高壓試(shi)驗時,除(chu)熟悉本(ben)說明書外,還必須(xu)嚴(yan)格執(zhi)行(xing)國家有關標準和(he)操作(zuo)規程。可參照GB311.1 – 97《高壓輸(shu)變設(she)備的(de)絕緣(yuan)配合,高壓試(shi)驗技術》;《電氣(qi)設(she)備預防性試(shi)驗規程》等
一、概述
智能(neng)耐壓試(shi)(shi)(shi)驗裝置(zhi)是(shi)根據國家(jia)*新電(dian)(dian)力(li)行業標準(zhun)而設(she)計(ji)的(de)、性能(neng)先進的(de)智能(neng)型耐壓試(shi)(shi)(shi)驗設(she)備,用于對(dui)各(ge)種電(dian)(dian)器產(chan)品(pin)、電(dian)(dian)氣(qi)元件、絕緣材料等(deng)(deng)進行規定(ding)電(dian)(dian)壓下的(de)絕緣強度試(shi)(shi)(shi)驗,以考核(he)產(chan)品(pin)的(de)絕緣水平,發現(xian)被試(shi)(shi)(shi)品(pin)的(de)絕緣缺陷(xian),衡量過電(dian)(dian)壓的(de)能(neng)力(li)。廣(guang)泛應用于電(dian)(dian)工(gong)制(zhi)造部門(men)、電(dian)(dian)力(li)運行部門(men)、科研單(dan)位和高等(deng)(deng)院校。
二、產品特(te)點
1. 320×240液晶顯示器、高速熱(re)敏打印機。
2. 高壓電壓、高壓電流(liu)、低壓電壓、低壓電流(liu)4路測(ce)量方式,高精度傳感器和高性能14位AD采集芯片。
3. 人機(ji)對話(hua)全鍵盤操作方(fang)式,智能化工作全過程,任選自動方(fang)式和(he)手(shou)動方(fang)式。
4. 實時(shi)顯示高壓(ya)(ya)(ya)電壓(ya)(ya)(ya)、高壓(ya)(ya)(ya)電流、低壓(ya)(ya)(ya)電壓(ya)(ya)(ya)、低壓(ya)(ya)(ya)電流,時(shi)間及耐(nai)壓(ya)(ya)(ya)結果,顯示直觀明了。
5. 完善(shan)的過壓(ya)(ya)、過流(liu)(liu)保(bao)護,任(ren)意設定輸出(chu)電(dian)(dian)壓(ya)(ya)、高(gao)壓(ya)(ya)電(dian)(dian)流(liu)(liu)上(shang)限、低(di)壓(ya)(ya)電(dian)(dian)流(liu)(liu)上(shang)限和(he)計(ji)時時間。
6. 具有回(hui)零(ling)檢測功(gong)能(neng),回(hui)零(ling)確定后(hou)才(cai)可進行試驗,**可靠。
7. 具有絕緣(yuan)電阻測試功能,直接反映被試品(pin)絕緣(yuan)強度。
8. 逼近式調壓(ya)算法,到達(da)設定(ding)電(dian)壓(ya)后(hou)自(zi)動(dong)(dong)耐壓(ya)計(ji)時,計(ji)時結束后(hou)自(zi)動(dong)(dong)降壓(ya)回(hui)零。
9. 超過設定(ding)高壓電流或(huo)低(di)壓電流時(shi)自動切斷電壓輸出,降壓回(hui)零,并發生聲光報警。
10. 精良的(de)軟硬件抗干擾設計,多種抗干擾手段(duan),適應惡劣電磁環(huan)境(jing)。
11. 自(zi)動錯誤(wu)診(zhen)斷,易于(yu)發現和解決問題(ti)。
12. 可選配無線遙控控制功(gong)能、遠程通信(xin)、門聯鎖(suo)警鈴(ling)、外接分壓器校驗(yan)接口等。
三(san)、設備組成
1、選型配置
標準配(pei)置(zhi)
|
□ 分體式(shi)
|
操作部分(fen):
□箱式(不大(da)于5kVA) / □臺(tai)式
容量: kVA(小于200kVA)
輸入:□AC220V / □AC380V
|
試驗變壓器:
□交流 / □交直流
□油變 / □干(gan)變 / □氣變
容(rong)量(liang): kVA(小于200kVA)
輸(shu)出:AC kV(小(xiao)于300kVA)
|
□ 一(yi)體(ti)式
|
□箱式(不大于20kV) / □臺式(不大于30kV)
容量: kVA(小于300kVA)
輸入:□AC220V / □AC380V 輸出:AC kV(不大于30kV)
|
客戶選配(pei)
|
□標準高壓分壓器
|
□保護(hu)球隙
|
□直流微安表
|
□放(fang)**
|
□保護水阻(zu)
|
□高壓濾波(bo)電容
|
其它:
|
2、對(dui)應(ying)實物
四(si)、技術指標(biao)
1、使用條件(jian):
(1)工(gong)作場(chang)所應(ying)無嚴重(zhong)影響(xiang)絕緣的氣體、蒸汽、化(hua)學性(xing)塵埃(ai)及其它爆炸性(xing)和腐蝕性(xing)介質。
(2)環境溫度 -20~+50℃
(3)環境濕度 ≤85% RH(無凝結水(shui))
2、控(kong)制箱(xiang)(臺(tai))參(can)數:(常(chang)規參(can)數見下表(biao))
(1)計時范圍:0-999S
(3)電壓精(jing)度(du) ≤1.5% ±1個字(F.S)
(4)電流(liu)精度 ≤1.5% ±1個字(F.S)
規格
|
容(rong)量
|
輸(shu) 入(ru) 電 源
|
輸 出 電 壓
|
重(zhong)量(kg)
|
相數
|
(V)
|
(A)
|
(V)
|
(A)
|
2/220
|
2
|
1
|
220
|
10
|
0-250
|
8
|
14
|
3/220
|
3
|
1
|
220
|
15
|
0-250
|
12
|
16
|
5/220
|
5
|
1
|
220
|
25
|
0-250
|
20
|
18
|
10/220
|
10
|
1
|
220
|
50
|
0-250
|
40
|
80
|
15/380
|
15
|
2
|
380
|
37.5
|
0-430
|
34.8
|
90
|
20/380
|
20
|
2
|
380
|
50
|
0-430
|
46.5
|
100
|
25/380
|
25
|
2
|
380
|
62.5
|
0-430
|
58.1
|
120
|
30/380
|
30
|
2
|
380
|
75
|
0-430
|
69.7
|
140
|
50/380
|
50
|
2
|
380
|
125
|
0-430
|
116.2
|
160
|
100/380
|
100
|
2
|
380
|
250
|
0-430
|
232.5
|
250
|
說明(ming):如有(you)特殊(shu)參數要求,可按用戶的(de)技術參數進行設計制作。
3、試驗變壓器參數(shu):(常規參數(shu)見(jian)下表)
規格(ge)
|
容量
kVA
|
低(di)壓側
|
高(gao)壓側
|
高壓側(ce)(交直流變壓器)
|
測量變比
|
60分鐘溫升℃
|
阻抗電壓%
|
空(kong)載電流
%
|
質(zhi)量
kg
|
電壓
V
|
電流(liu)
A
|
交流輸出
|
直流輸(shu)出
|
電壓kV
|
電流
|
電(dian)壓kV
|
電流
|
1.5/50
|
1.5
|
200
|
7.5
|
50
|
30
|
70
|
21.4
|
500
|
50
|
10
|
<4
|
19.5
|
3/50
|
3
|
200
|
15
|
50
|
60
|
70
|
42.9
|
500
|
50
|
10
|
<4
|
27
|
5/50
|
5
|
200
|
25
|
50
|
100
|
70
|
71.4
|
500
|
50
|
10
|
<4
|
52
|
10/50
|
10
|
200
|
50
|
50
|
200
|
70
|
142.9
|
500
|
50
|
10
|
<4
|
80
|
15/50
|
15
|
400
|
37.5
|
50
|
300
|
70
|
214.3
|
500
|
50
|
8
|
<4
|
120
|
20/50
|
20
|
400
|
50
|
50
|
400
|
70
|
285.7
|
500
|
50
|
8
|
<4
|
140
|
30/50
|
30
|
400
|
75
|
50
|
600
|
70
|
428.6
|
500
|
50
|
8
|
<4
|
155
|
50/50
|
50
|
400
|
125
|
50
|
1000
|
70
|
714.3
|
500
|
50
|
8
|
<4
|
184
|
10/100
|
10
|
200
|
50
|
100
|
100
|
140
|
71.4
|
1000
|
50
|
10
|
<4
|
135
|
15/100
|
15
|
400
|
37.5
|
100
|
150
|
140
|
107.1
|
1000
|
50
|
8
|
<4
|
150
|
20/100
|
20
|
400
|
50
|
100
|
200
|
140
|
142.9
|
1000
|
50
|
8
|
<4
|
215
|
30/100
|
30
|
400
|
75
|
100
|
300
|
140
|
214.3
|
1000
|
50
|
8
|
<4
|
250
|
50/100
|
50
|
400
|
125
|
100
|
500
|
140
|
357.1
|
1000
|
50
|
8
|
<4
|
290
|
10/150
|
10
|
200
|
50
|
100
|
66.7
|
140
|
47.6
|
1500
|
50
|
10
|
<4
|
180
|
15/150
|
15
|
400
|
37.5
|
150
|
100
|
210
|
71.4
|
1500
|
50
|
8
|
<4
|
200
|
20/150
|
30
|
400
|
50
|
150
|
133.3
|
210
|
95.2
|
1500
|
50
|
8
|
<4
|
220
|
30/150
|
30
|
400
|
75
|
150
|
200
|
210
|
142.9
|
1500
|
50
|
8
|
<4
|
280
|
50/150
|
50
|
400
|
125
|
150
|
333.3
|
210
|
238.1
|
1500
|
50
|
8
|
<4
|
340
|
說(shuo)明(ming):如(ru)有特殊參(can)數(shu)要求,可按用戶的技(ji)術參(can)數(shu)進行設(she)計(ji)制作(zuo)。
上(shang)表的(de)重量以油浸式(shi)(shi)試(shi)(shi)驗(yan)變(bian)壓器(qi)(qi)為例(li),干式(shi)(shi)試(shi)(shi)驗(yan)變(bian)壓器(qi)(qi)和充氣式(shi)(shi)試(shi)(shi)驗(yan)變(bian)壓器(qi)(qi)稍有不(bu)同。
五、接(jie)線及工(gong)作(zuo)原理
1、調壓部分(fen)接線(xian)及原理
調壓部(bu)分由(you)控(kong)制(zhi)部(bu)分和試(shi)驗變壓器組成(cheng)(cheng)(cheng)。控(kong)制(zhi)部(bu)分是由(you)接(jie)觸(chu)式調壓器、單(dan)片機(ji)控(kong)制(zhi)系統、液(ye)晶、打印(yin)機(ji)、信號測量、電路(lu)保護組成(cheng)(cheng)(cheng)。試(shi)驗變壓器由(you)低壓繞組、高壓繞組、儀表繞組三部(bu)分組成(cheng)(cheng)(cheng)。
試(shi)(shi)驗變壓器(qi)為(wei)交(jiao)直(zhi)(zhi)流(liu)(liu)兩用時,試(shi)(shi)驗變壓器(qi)配置了高壓硅(gui)堆(dui)(油變、氣(qi)(qi)變為(wei)內置,干變為(wei)外置),高壓可(ke)輸(shu)出交(jiao)流(liu)(liu)和直(zhi)(zhi)流(liu)(liu)。輸(shu)出交(jiao)流(liu)(liu)時,要求(qiu)接入(ru)短路桿(油變、氣(qi)(qi)變)或去(qu)掉(diao)外置硅(gui)堆(dui)(干變);輸(shu)出直(zhi)(zhi)流(liu)(liu)時,要求(qiu)擰出短路桿(油變、氣(qi)(qi)變)或加(jia)上外置硅(gui)堆(dui)(干變)
通(tong)過(guo)接入工頻電源(yuan),調節調壓(ya)器,以獲得所需要的(de)試驗高壓(ya)電壓(ya)值。其(qi)工作原(yuan)理見圖1:
2、試驗部分接線及原理
做耐壓(ya)(ya)試(shi)驗時,控制部分、變壓(ya)(ya)器(qi)的(de)接(jie)地端及高(gao)壓(ya)(ya)尾必須可靠接(jie)地。有條件的(de)情況(kuang)下,做工(gong)頻耐壓(ya)(ya)試(shi)驗請加上限流電阻、標(biao)準高(gao)壓(ya)(ya)分壓(ya)(ya)器(qi)、球(qiu)(qiu)隙(xi)保(bao)護電阻及保(bao)護球(qiu)(qiu)隙(xi),如圖(tu)3。
做直(zhi)(zhi)流耐壓(ya)試驗請另外加上微安表(biao),微安表(biao)必須接在硅(gui)堆和被試器(qi)之間,油變或氣變一(yi)般擰(ning)(ning)在高(gao)壓(ya)頭上面(要求(qiu)擰(ning)(ning)出短路桿(gan)),干(gan)變擰(ning)(ning)在外置硅(gui)堆上面;為了(le)更準(zhun)確顯示高(gao)壓(ya)直(zhi)(zhi)流泄(xie)漏電流,請將分(fen)壓(ya)器(qi)的高(gao)壓(ya)線接在微安表(biao)和硅(gui)堆之間,(油變、氣變)如圖(tu)4,(干(gan)變)如圖(tu)5。
耐壓(ya)(ya)(ya)試(shi)驗中限流(liu)電阻(zu)(zu)R1應根據試(shi)驗變(bian)壓(ya)(ya)(ya)器的額定(ding)容量(liang)來選擇(ze)。如高(gao)壓(ya)(ya)(ya)側(ce)額定(ding)輸出電流(liu)在100~300mA時,可取(qu)0.5~1Ω/V(試(shi)驗電壓(ya)(ya)(ya));高(gao)壓(ya)(ya)(ya)側(ce)額定(ding)輸出電流(liu)為1A以上時,可取(qu)1Ω/V(試(shi)驗電壓(ya)(ya)(ya))。常(chang)用(yong)水電阻(zu)(zu)作為限流(liu)電阻(zu)(zu),管子(zi)長度可按150kV/m考(kao)慮(lv),管子(zi)粗細應具有足夠(gou)的熱容量(liang)(水阻(zu)(zu)液配(pei)(pei)制(zhi)方法:用(yong)蒸餾水加(jia)入適量(liang)硫酸銅配(pei)(pei)制(zhi)成各(ge)種(zhong)不同的阻(zu)(zu)值(zhi))。
球間(jian)隙及保護電(dian)(dian)(dian)阻:當電(dian)(dian)(dian)壓(ya)(ya)超(chao)過球間(jian)隙整定(ding)值時(一般(ban)取(qu)試(shi)(shi)驗電(dian)(dian)(dian)壓(ya)(ya)的110%~120%),球間(jian)隙放電(dian)(dian)(dian),對被試(shi)(shi)品起(qi)到保護作(zuo)用。球間(jian)隙保護電(dian)(dian)(dian)阻可按1Ω/V(試(shi)(shi)驗電(dian)(dian)(dian)壓(ya)(ya))選取(qu)。
在(zai)(zai)(zai)工(gong)頻耐壓(ya)(ya)(ya)(ya)試(shi)(shi)驗中,低電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)側測(ce)(ce)量(liang)電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(儀表(biao)電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya))不是非常準(zhun)確的(de),其原因是由于(yu)試(shi)(shi)驗變(bian)壓(ya)(ya)(ya)(ya)器存在(zai)(zai)(zai)著(zhu)(zhu)漏抗(kang)(kang),在(zai)(zai)(zai)這個漏抗(kang)(kang)上必然(ran)存在(zai)(zai)(zai)著(zhu)(zhu)壓(ya)(ya)(ya)(ya)降或容(rong)升,使試(shi)(shi)品上的(de)電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)低于(yu)或高(gao)(gao)于(yu)低壓(ya)(ya)(ya)(ya)側測(ce)(ce)量(liang)電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)表(biao)上反映出來的(de)電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)。工(gong)頻耐壓(ya)(ya)(ya)(ya)試(shi)(shi)驗時(shi),被(bei)試(shi)(shi)品上的(de)電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)高(gao)(gao)于(yu)試(shi)(shi)驗變(bian)壓(ya)(ya)(ya)(ya)器的(de)輸出電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya),也就是所謂容(rong)升現象。感應耐壓(ya)(ya)(ya)(ya)試(shi)(shi)驗時(shi),試(shi)(shi)驗變(bian)壓(ya)(ya)(ya)(ya)器的(de)漏抗(kang)(kang)必然(ran)存在(zai)(zai)(zai)著(zhu)(zhu)壓(ya)(ya)(ya)(ya)降。為了準(zhun)確測(ce)(ce)量(liang)被(bei)試(shi)(shi)品上所施加的(de)電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya),因此常在(zai)(zai)(zai)高(gao)(gao)壓(ya)(ya)(ya)(ya)側接(jie)入標準(zhun)高(gao)(gao)壓(ya)(ya)(ya)(ya)分壓(ya)(ya)(ya)(ya)器來測(ce)(ce)量(liang)電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)。
六、操作要點
1、試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)前,應(ying)了(le)解被(bei)試(shi)(shi)(shi)(shi)品(pin)的(de)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)電壓(ya),同時(shi)了(le)解被(bei)試(shi)(shi)(shi)(shi)品(pin)的(de)其(qi)他(ta)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)項目及以(yi)前的(de)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)結果。若被(bei)試(shi)(shi)(shi)(shi)品(pin)有缺陷或(huo)異(yi)常,應(ying)在(zai)消除后再進行耐(nai)壓(ya)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)。
2、試驗(yan)現場應圍(wei)好(hao)遮攔或圍(wei)繩,掛好(hao)標示牌,并派專人監護(hu)。
3、試驗前,被(bei)試品表面應(ying)擦(ca)拭干凈(jing),將(jiang)被(bei)試品的外殼(ke)和非被(bei)試繞組(zu)可靠接地(di)。被(bei)試品為新沖油(you)設備(bei)(bei)時(shi),應(ying)按《規程(cheng)》規定使油(you)靜(jing)止一定時(shi)間(jian)再升(sheng)壓,對(dui)110kV及以下(xia)的充(chong)油(you)電(dian)力設備(bei)(bei),在注滿油(you)后靜(jing)置(zhi)時(shi)間(jian)應(ying)不少于24小(xiao)時(shi),對(dui)220kV及330kV的充(chong)油(you)電(dian)力設備(bei)(bei),靜(jing)置(zhi)時(shi)間(jian)應(ying)不少于48小(xiao)時(shi)。
4、接好試驗接線后,應由有經驗的人員檢查,確認無(wu)誤后方(fang)可升壓。
5、升(sheng)壓(ya)(ya)前,首先檢(jian)查調(diao)壓(ya)(ya)器(qi)是否在零(ling)位。調(diao)壓(ya)(ya)器(qi)在零(ling)位方可升(sheng)壓(ya)(ya)。
6、升壓(ya)(ya)過程(cheng)中不(bu)僅要(yao)監視電(dian)壓(ya)(ya)的變(bian)(bian)化,還(huan)應(ying)監視電(dian)流(liu)的變(bian)(bian)化,以及被試品泄(xie)漏電(dian)流(liu)的變(bian)(bian)化。升壓(ya)(ya)時(shi)(shi)要(yao)均(jun)(jun)勻(yun)升壓(ya)(ya),不(bu)能太快。升至規定(ding)試驗電(dian)壓(ya)(ya)時(shi)(shi),開始計時(shi)(shi),時(shi)(shi)間到后,緩慢均(jun)(jun)勻(yun)降(jiang)下電(dian)壓(ya)(ya)。絕不(bu)允(yun)許(xu)不(bu)降(jiang)壓(ya)(ya)就先(xian)跳開電(dian)源開關。
7、試(shi)驗中(zhong)發現被試(shi)品(pin)有異常聲(sheng)響、冒煙等(deng)應立即(ji)降下電(dian)壓(ya),拉開電(dian)源(yuan),在(zai)高壓(ya)側掛上接地線后(hou),再(zai)查明原因。耐(nai)壓(ya)試(shi)驗前(qian)后(hou)均應測(ce)量被試(shi)品(pin)的絕(jue)緣電(dian)阻。
七(qi)、面板功(gong)能說明
打(da)(da)印(yin)機:打(da)(da)印(yin)機是熱敏打(da)(da)印(yin)機,當試驗(yan)完成后按鍵盤(pan)上的“打(da)(da)印(yin)”按鈕打(da)(da)印(yin)試驗(yan)結果。
RS232:RS232是(shi)與計算機相連的串口(kou)通信接(jie)口(kou),是(shi)用戶選(xuan)配接(jie)口(kou),本裝置沒有配置這個(ge)接(jie)口(kou)。
LCD對比度:因為液晶顯示(shi)屏在溫(wen)度和光(guang)線(xian)有所不同時稍(shao)有些變(bian)化,可以通過LCD對比度調節(jie)背光(guang)到適合(he)亮度。
液(ye)晶(jing): 320x240像素(su)點陣白色背光液(ye)晶(jing),在(zai)強光和(he)陰暗環境(jing)下(xia)都(dou)十(shi)分清楚。
指(zhi)示燈(deng):由啟動燈(deng)、零位燈(deng)、指(zhi)示燈(deng)三個燈(deng)組成(cheng),啟動燈(deng)和(he)警示燈(deng)是高(gao)亮七(qi)彩(cai)燈(deng)。
操作(zuo)提示(shi):有(you)一些簡短的提示(shi)語(yu)句(ju)和安裝接線圖。
緊急(ji)(ji)開關:在緊急(ji)(ji)情況下按此開關,即可以切(qie)斷變(bian)壓器(qi)電源(yuan),也可以切(qie)斷工作電源(yuan)。(箱式安裝在面(mian)板上,臺(tai)式安裝在柜體上)
鍵(jian)盤:由(you)上、下、左、右、設(she)(she)置、打印、確定、取消(xiao)8個鍵(jian)組成(cheng),是用戶和設(she)(she)備(bei)交互的終端(duan)。
電(dian)(dian)源開關:工作(zuo)電(dian)(dian)源,帶通(tong)電(dian)(dian)指示燈(deng)。
八(ba)、軟(ruan)件使用說明(ming)
按試驗要求將控制(zhi)部分、試驗變壓器、被試品正確接好線,必(bi)須(xu)可靠接地,請參考圖(tu)(tu)1、圖(tu)(tu)2、圖(tu)(tu)3、圖(tu)(tu)4、圖(tu)(tu)5。
1、開機使用(yong)
開機處于“歡迎界面”,如(ru)圖7:
根據鍵盤的示圖8,按上↑、下↓、左(zuo)←,右→可以切換“自(zi)動耐(nai)壓試(shi)(shi)驗(yan)(yan)(yan)”或“手(shou)動耐(nai)壓試(shi)(shi)驗(yan)(yan)(yan)”,在“自(zi)動試(shi)(shi)驗(yan)(yan)(yan)”或“手(shou)動試(shi)(shi)驗(yan)(yan)(yan)”里(li)面選擇“交(jiao)流試(shi)(shi)驗(yan)(yan)(yan)方式(shi)”或“直(zhi)流試(shi)(shi)驗(yan)(yan)(yan)方式(shi)”。如圖9
說明(ming):
(1)當配置的(de)是交(jiao)直(zhi)流(liu)兩用(yong)控制部(bu)分(fen)時,使用(yong)直(zhi)流(liu)輸出(chu)時軟件操作請(qing)進入直(zhi)流(liu)試驗方(fang)式,交(jiao)流(liu)輸出(chu)時軟件操作請(qing)進入交(jiao)流(liu)試驗方(fang)式,如果選擇錯誤會(hui)導(dao)致儀器顯(xian)示電壓會(hui)和輸出(chu)實(shi)際電壓不(bu)一致。
(2)當(dang)(dang)配(pei)置(zhi)的是交直(zhi)流兩(liang)用(yong)變壓(ya)器時(shi),使(shi)用(yong)直(zhi)流時(shi)請將變壓(ya)器的短路(lu)桿取出,當(dang)(dang)使(shi)用(yong)交流時(shi)請將短路(lu)桿插(cha)入擰緊。
(3)如果(guo)配置的是交流控制部分時,軟件界面里就(jiu)沒(mei)有交直流試(shi)驗方式(如圖9)的選擇項。
選中(zhong)試驗方式后,按確定(ding)可以(yi)進入主界面,如圖10:
動態顯示(shi)區(qu):一直(zhi)處于(yu)采集信號,并顯示(shi)高壓(ya)(ya)電壓(ya)(ya)、高壓(ya)(ya)電流(liu)、低壓(ya)(ya)電壓(ya)(ya)、低壓(ya)(ya)電流(liu)。
結果顯(xian)示(shi)(shi)(shi)區:如果試(shi)驗沒有被(bei)擊穿時,顯(xian)示(shi)(shi)(shi)平(ping)(ping)均(jun)高壓(ya)(ya)電(dian)(dian)(dian)(dian)壓(ya)(ya),平(ping)(ping)均(jun)高壓(ya)(ya)電(dian)(dian)(dian)(dian)流(liu),平(ping)(ping)均(jun)低(di)壓(ya)(ya)電(dian)(dian)(dian)(dian)壓(ya)(ya),平(ping)(ping)均(jun)低(di)壓(ya)(ya)電(dian)(dian)(dian)(dian)流(liu),絕緣電(dian)(dian)(dian)(dian)阻(zu);否之,顯(xian)示(shi)(shi)(shi)峰值(zhi)電(dian)(dian)(dian)(dian)壓(ya)(ya),峰值(zhi)電(dian)(dian)(dian)(dian)流(liu),低(di)壓(ya)(ya)電(dian)(dian)(dian)(dian)壓(ya)(ya),低(di)壓(ya)(ya)電(dian)(dian)(dian)(dian)流(liu)。
設(she)置(zhi)數(shu)(shu)據區:設(she)置(zhi)試驗中(zhong)需要的(de)參數(shu)(shu)數(shu)(shu)據輸出電(dian)(dian)壓(ya)為(wei)(wei)在(zai)自(zi)動(dong)方式下的(de)升壓(ya)目標耐(nai)壓(ya)值(zhi)耐(nai)壓(ya)時(shi)間為(wei)(wei)耐(nai)壓(ya)過程的(de)時(shi)間長度電(dian)(dian)流(liu)(liu)(liu)上(shang)限(xian)(xian)為(wei)(wei)高(gao)壓(ya)電(dian)(dian)流(liu)(liu)(liu)峰(feng)值(zhi)的(de)上(shang)限(xian)(xian),高(gao)壓(ya)電(dian)(dian)流(liu)(liu)(liu)超過電(dian)(dian)流(liu)(liu)(liu)上(shang)限(xian)(xian)將(jiang)認(ren)為(wei)(wei)擊穿過流(liu)(liu)(liu)保護為(wei)(wei)低(di)壓(ya)電(dian)(dian)流(liu)(liu)(liu)峰(feng)值(zhi)的(de)上(shang)限(xian)(xian),低(di)壓(ya)電(dian)(dian)流(liu)(liu)(liu)超過過流(liu)(liu)(liu)保護將(jiang)認(ren)為(wei)(wei)擊穿
信息顯示(shi)區:顯示(shi)試驗(yan)過程中的試驗(yan)狀態和提示(shi)信息。
試驗操作區:選擇(ze)設置(zhi)、試驗、回零命令。
2、設置參(can)數
在主界面上,選(xuan)中“設(she)置”,然后(hou)按確定后(hou)進入設(she)置界面,如圖11:
按左←,右→時切換光(guang)標(biao)(biao)移(yi)動位置(zhi),按上↑、下(xia)↓時更改光(guang)標(biao)(biao)位置(zhi)數據的(de)值。光(guang)標(biao)(biao)位置(zhi)和設(she)(she)置(zhi)的(de)數值全(quan)部可以自動循環,前且在使(shi)用時有(you)默認的(de)標(biao)(biao)準值。如果所有(you)的(de)參數都設(she)(she)置(zhi)完(wan)成(cheng),按取(qu)消(xiao)退(tui)出設(she)(she)置(zhi)回到主界面開始狀態。
3、手動試驗
零(ling)(ling)(ling)(ling)位檢(jian)查—當選中(zhong)“試驗”后,按(an)確定就進入提示試驗狀態。如(ru)果(guo)調壓(ya)器不(bu)在零(ling)(ling)(ling)(ling)位,將提示“試驗前(qian)請(qing)先回零(ling)(ling)(ling)(ling)”,退出(chu)試驗并且切換到回零(ling)(ling)(ling)(ling)命令。
試(shi)驗(yan)(yan)過程—回(hui)零確(que)認后,可以進行試(shi)驗(yan)(yan)。選中“試(shi)驗(yan)(yan)”后按確(que)定,接觸器合閘(zha),這時輸出電壓幾(ji)乎為(wei)0,如(ru)圖12:
按上(shang)(shang)↑,高(gao)壓(ya)(ya)(ya)電壓(ya)(ya)(ya)將(jiang)不(bu)斷升壓(ya)(ya)(ya),松開就停止升壓(ya)(ya)(ya),如果到上(shang)(shang)限就提示滿量程(cheng);
按下↓,高壓(ya)(ya)電壓(ya)(ya)將不斷降壓(ya)(ya),松開(kai)就停止(zhi)降壓(ya)(ya),如果到下限就提(ti)示已回零;
按計(ji)時(shi)←,計(ji)時(shi)開始工作,到耐壓時(shi)間計(ji)時(shi)結束完成試驗;
按取消→,取消試驗過程;
在(zai)升(sheng)壓(ya)(ya)(ya)過(guo)(guo)程中,如(ru)果高(gao)壓(ya)(ya)(ya)電流(liu)峰(feng)(feng)值(zhi)(zhi)超過(guo)(guo)“電流(liu)上限(xian)”值(zhi)(zhi)或低(di)壓(ya)(ya)(ya)電流(liu)峰(feng)(feng)值(zhi)(zhi)超過(guo)(guo)“過(guo)(guo)流(liu)保護(hu)”值(zhi)(zhi)將認為被試(shi)品(pin)被擊穿(chuan),接(jie)(jie)觸器(qi)立刻分閘(zha)并(bing)顯示試(shi)驗結(jie)果,包括峰(feng)(feng)值(zhi)(zhi)電壓(ya)(ya)(ya)、峰(feng)(feng)值(zhi)(zhi)電流(liu)、低(di)壓(ya)(ya)(ya)電流(liu)等(deng),調壓(ya)(ya)(ya)器(qi)開始(shi)回(hui)零,回(hui)零完(wan)(wan)成試(shi)驗結(jie)束。如(ru)果在(zai)耐壓(ya)(ya)(ya)過(guo)(guo)程中,高(gao)壓(ya)(ya)(ya)電流(liu)和(he)低(di)壓(ya)(ya)(ya)電流(liu)峰(feng)(feng)值(zhi)(zhi)沒有超設(she)置(zhi)上限(xian)值(zhi)(zhi),認為被試(shi)品(pin)未擊穿(chuan),結(jie)果顯示區就顯示耐壓(ya)(ya)(ya)電壓(ya)(ya)(ya)、高(gao)壓(ya)(ya)(ya)電流(liu)、低(di)壓(ya)(ya)(ya)電流(liu)、絕緣電阻(zu)等(deng),調壓(ya)(ya)(ya)器(qi)開始(shi)回(hui)零,回(hui)零完(wan)(wan)成后接(jie)(jie)觸器(qi)分閘(zha)試(shi)驗結(jie)束。
4、自動試驗
自動試驗和(he)手動試驗的(de)試驗過程類似(si),首先(xian)也進(jin)行回零檢查(cha),確認后(hou)進(jin)入如(ru)(ru)下界面,如(ru)(ru)圖13:
按上方法切換到“開(kai)始”確定后進(jin)行試(shi)驗(yan),與手動試(shi)驗(yan)不(bu)同之處(chu)就是升壓過程將自(zi)動升壓到“輸出(chu)電壓”值,然后進(jin)行計時。
升壓(ya)過(guo)程為逼近(jin)方(fang)式,首先升到(dao)到(dao)接近(jin)目標值,然后(hou)再進行微調(diao),保證高壓(ya)電壓(ya)值幾乎為輸出電壓(ya)值。
5、功能選擇
按鍵盤(pan)上(shang)的“設(she)置”就進入功能界(jie)面,如圖14:
進(jin)入(ru)功能界面后,可以選(xuan)擇(ze)“時鐘設(she)置”、“注意事項(xiang)”等(deng)界面。
時(shi)鐘設置(zhi):設置(zhi)時(shi)鐘的時(shi)間(jian),為打印(yin)報表提供時(shi)間(jian)依據。
注(zhu)意(yi)事項:為(wei)用戶提供一些操(cao)作(zuo)規范和(he)**注(zhu)意(yi)事項。
6、打印(yin)
按鍵盤“打(da)印”按鍵可以打(da)印試驗果,在此(ci)不(bu)贅述。
七、產品維護
1、開箱驗收時,應(ying)檢查主(zhu)控回路接線是否(fou)松動,調(diao)壓器電刷是否(fou)接觸良好。
2.、長期不(bu)用時,使用前(qian)應(ying)用500V兆歐表測量絕緣電阻,其阻值不(bu)低于(yu)0.5MΩ。
3、電源電壓(ya)應符(fu)合控制箱(xiang)(臺)說明書上的輸入電壓(ya)值要求(qiu)。
4、本控制箱(臺)設有過(guo)電流保(bao)護,出廠已調整為額定電流的50%。用于小(xiao)負(fu)載時,應根據被試品的額定容量電流重新設定;
5、使(shi)用完畢后,應關好(hao)控制箱(臺)門蓋,以保持內部清潔。
八(ba)、注意事(shi)項
1、按照您所進(jin)行的(de)(de)(de)試(shi)驗(yan)接(jie)好工(gong)作(zuo)線(xian)路(lu)。試(shi)驗(yan)變壓器的(de)(de)(de)外殼以(yi)及操作(zuo)系統的(de)(de)(de)外殼必須可(ke)靠接(jie)地(di)。試(shi)驗(yan)變壓器的(de)(de)(de)測量繞(rao)組(zu)的(de)(de)(de)F端和(he)外殼必須可(ke)靠接(jie)地(di)。
2、做串級(ji)試驗時,**級(ji)、第三(san)級(ji)試驗變壓(ya)器(qi)的(de)低(di)壓(ya)繞組(zu)成X端(duan),測量繞組(zu)的(de)F端(duan)以及高壓(ya)繞組(zu)的(de)X端(duan)(高壓(ya)端(duan))均接本級(ji)試驗變壓(ya)器(qi)具外(wai)(wai)殼。**級(ji)、第三(san)級(ji)試驗變壓(ya)器(qi)的(de)外(wai)(wai)殼必須通過(guo)絕緣支(zhi)架(jia)接地。
接通電(dian)源(yuan)前,控制箱(臺(tai))的調壓(ya)器必(bi)須(xu)調到(dao)零位后方可接通電(dian)源(yuan),合閘(zha),開(kai)始升壓(ya)。
3、從零開(kai)始勻速(su)旋轉調壓(ya)(ya)(ya)器手輪升(sheng)壓(ya)(ya)(ya)。升(sheng)壓(ya)(ya)(ya)方式(shi)有(you):快(kuai)速(su)升(sheng)壓(ya)(ya)(ya)法,即(ji)20s逐級(ji)升(sheng)壓(ya)(ya)(ya)法;慢速(su)升(sheng)壓(ya)(ya)(ya)法,即(ji)60s逐級(ji)升(sheng)壓(ya)(ya)(ya)法;極慢速(su)升(sheng)壓(ya)(ya)(ya)法供選用。電(dian)(dian)壓(ya)(ya)(ya)從零開(kai)始按(an)一定的(de)(de)(de)(de)(de)升(sheng)壓(ya)(ya)(ya)方式(shi)和速(su)度上升(sheng)到(dao)您(nin)所需(xu)的(de)(de)(de)(de)(de)額(e)定試(shi)(shi)(shi)驗(yan)電(dian)(dian)壓(ya)(ya)(ya)的(de)(de)(de)(de)(de)75%后,再以每秒(miao)2%額(e)定試(shi)(shi)(shi)驗(yan)電(dian)(dian)壓(ya)(ya)(ya)的(de)(de)(de)(de)(de)速(su)度升(sheng)到(dao)您(nin)所需(xu)的(de)(de)(de)(de)(de)試(shi)(shi)(shi)驗(yan)電(dian)(dian)壓(ya)(ya)(ya),并密(mi)切(qie)注(zhu)意測量(liang)儀表(biao)的(de)(de)(de)(de)(de)及(ji)被(bei)試(shi)(shi)(shi)品(pin)的(de)(de)(de)(de)(de)情(qing)況(kuang)。升(sheng)壓(ya)(ya)(ya)過(guo)程(cheng)中或試(shi)(shi)(shi)驗(yan)過(guo)程(cheng)中如發現測量(liang)儀表(biao)的(de)(de)(de)(de)(de)指示及(ji)被(bei)試(shi)(shi)(shi)品(pin)情(qing)況(kuang)異(yi)常,應立即(ji)降壓(ya)(ya)(ya),切(qie)斷電(dian)(dian)源,查明情(qing)況(kuang)。
4、試驗完畢后(hou)(hou),應(ying)在(zai)等調壓器返回至零位,然后(hou)(hou)切斷電源。
5、本產品不得超(chao)過(guo)額定參數使用。
6、使用本產品做高(gao)壓(ya)試(shi)驗(yan)(yan)時(shi),除熟悉(xi)本說明(ming)書外,還(huan)必須(xu)嚴格執(zhi)行國家有關標準和(he)操作規程(cheng)。可參照GB311.1 – 97《高(gao)壓(ya)輸變設備的絕緣配合,高(gao)壓(ya)試(shi)驗(yan)(yan)技術》;《電氣設備預防性試(shi)驗(yan)(yan)規程(cheng)》等(deng)。
7、控制(zhi)(zhi)箱(臺)應與試驗(yan)變壓器配套使(shi)用,控制(zhi)(zhi)箱(臺)的使(shi)用方法,請詳(xiang)細參閱(yue)控制(zhi)(zhi)器的使(shi)用說(shuo)明書。